Comparison of osteointegration property between PEKK and PEEK: Effects of surface structure and chemistry

Yuan, Bo, Cheng, Qinwen, Zhao, Rui, Zhu, Xiangdong, Yang, Xiao, Yang, Xi, Zhang, Kai, Song, Yueming +1 more·2018·Biomaterials

Abstract

Weak osteointegration affects the long-term stability of polyaryletherketone (PAEK) implants. Surface modification provides a potential solution to improve the osteointegration property of PAEKs. Polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) are two representative PAEK materials, but the latter has more ketone groups and better potential for surface chemical modification than the former. In this work, porous PEKK (PEKK-P) and PEEK (PEEK-P) were fabricated by a porogen leaching method. The samples were treated with 80% sulfuric acid (PEKK-SP and PEEK-SP) and then simulated body fluid (SBF) incubation (PEKK-BSP and PEEK-BSP). More micropores and higher hydrophilic SO 3 H groups were found on PEKK-SP than PEEK-SP. Likely, more bone-like apatite crystals deposited on PEKK-BSP than PEEK-BSP. To evaluate their osteointegration properties, the samples were implanted in femoral condyle defects (Φ3 × 4 mm 3) of rat models, and micro-computed tomography (μ-CT), histology and mechanical analyzes were performed on the retrieved specimens. For control groups, i.e. the dense samples (PEKK-D and PEEK-D), only a handful of bone creeping growth on the implant surface was seen on them. However, with the interconnected macropores, surface micro/nano topography and bone-like apatite, notable bone growth into the inner pores was observed on PEKK-BSP and PEEK-BSP. Furthermore, quantitative analyses confirmed that the newly formed bone in PEKK-BSP was nearly more than doubled than that in PEEK-BSP. The push-out force testing results (PEKK-D ≈ PEEK-D < PEKK-P ≈ PEEK-P < PEEK-BSP < PEKK-BSP) suggested that the surface chemical modification (sulfonation treatment followed by SBF incubation) along with build-in porous structure played more important role in enhancing the mechanical stability of both PAEK materials than just the physical structure change. Our results revealed that PEKK with more ketone groups allowed easier sulfonation and better bone-like apatite deposition than PEEK, thus endowing PEKK-BSP with better osteointegration and mechanical stability than PEEK-BSP. Therefore, surface modified PEKK could be potential candidate for spinal and orthopedic applications requiring good osteointegration property.

Integrity signals

Registry

Crossref · 10.1016/j.biomaterials.2018.04.014

Cites

58 of 58 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • PEKK has a lower melt viscosity, making it easier to work with during printing, and its printing temperature is slightly lower than that of PEEK.

    “Additionally, PEKK has a lower melt viscosity, making it easier to work with during printing. Furthermore, the printing temperature of PEKK is slightly lower than that of PEEK.”
  • PEKK features an additional ketone group in its chemical structure compared to PEEK.

    “In comparison to PEEK, PEKK features an additional ketone group in its chemical structure.”
  • PEKK offers superior thermal stability with a higher glass transition temperature (Tg) at around 162°C, in contrast to PEEK's Tg of about 143°C.

    “PEKK offers superior thermal stability, boasting a higher glass transition temperature (Tg) at around 162 ◦ C in contrast to PEEK, with a Tg of about 143 ◦ C.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Yuan, B., Cheng, Q., Zhao, R., Zhu, X., Yang, X., Yang, X., Zhang, K., Song, Y., & Zhang, X.
Affiliations
  • Sichuan University (CN)
  • West China Hospital of Sichuan University (CN)
Corresponding author
  • Zhu, Xiangdong
  • Zhang, Kai
Venue
Biomaterials
Publisher
Elsevier BV
Published
2018-07
Volume
170
Pages
116-126
ISSN
0142-9612 (ISSN-L)
OpenAlex
W2797771381
Cited by
204
References
58
Citations by year
2026: 4 · 2025: 41 · 2024: 27 · 2023: 26 · 2022: 26 · 2021: 35 · 2020: 21 · 2019: 19 · 2018: 5
FWCI
7.99
Type
journal article
Language
en
Open access
closed
Locations
  • Biomaterials (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Key Research and Development Program of China (2016YFC1102000, 2016YFC1102001, 2016YFC1102004)
  • Provincial Key Technology Support Program of Sichuan (2015SZ0026)
  • 111” Project of China (B16033)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
  • Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
  • Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
Keywords
osseointegration, PEEK, PEKK, sulfonation, surface modification, porous implants, porogen leaching, simulated body fluid, femoral condyle defect, push-out force, bone ingrowth, orthopedic implants
MeSH terms
Animals, Apatites, Benzophenones, Body Fluids, Elements, Female, Ketones, Polyethylene Glycols, Polymers, Surface Properties, Water, Porosity, Osseointegration, Weight-Bearing, Rats, Sprague-Dawley, Imaging, Three-Dimensional, X-Ray Microtomography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review