Tissue-engineered submillimeter-diameter vascular grafts for free flap survival in rat model
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Vascular grafts for free flap transfers should be of very small diameter and remain patent for approximately three weeks to supply blood until the revascularization from the surrounding tissue is established, with the autologous vein grafts acting as the gold standard. Artificial submillimeter-diameter vascular grafts with clinically useful size of 0.6 mm inner diameter and 5 cm length were prepared and evaluated by replacing the axial artery of free flap in rats. The rat tail artery, selected as a novel bioscaffold material, was decellularized using ultrahigh-hydrostatic pressure (UHP) method and compared with the detergent-based conventional method. To induce rapid endothelialization, the graft lumen was modified with synthesized peptides, having high affinity to the endothelial progenitor cells. The UHP method and peptide modification at 37 °C were found to preserve the extracellular matrix structure well, leading to the stable immobilization of the peptide at the luminal surface. These grafts showed the neointima formation, even at the center position far from the native vessels, remained patent for three weeks, and resulted in the flap survival in the rat free-flap model. The tissue-engineered vascular grafts with functionalized lumen have great future potential as an alternative to autologous vein grafts in free flap transfers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An overview of tissue and whole organ decellularization processes
Crapo, P. M., Gilbert, T. W., & Badylak, S. F. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.057 · Cited by 3,591
Cited by
Zhang, X., Chen, X., Hong, H., Hu, R., Liu, J., & Liu, C. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.09.014 · Cited by 680
Exploiting crosslinked decellularized matrix to achieve uterus regeneration and construction
Yao, Q., Zheng, Y.-W., Lin, H.-L., Lan, Q.-H., Huang, Z.-W., Wang, L.-F., Chen, R., Xiao, J., Kou, L., Xu, H.-L., et al. (2020) · Artificial Cells, Nanomedicine, and Biotechnology · doi:10.1080/21691401.2019.1699828 · Cited by 56
Mahara, A., Kitai, M., Masunaga, H., Hikima, T., Ohya, Y., Sasaki, S., Sakurai, S., & Yamaoka, T. (2020) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36960 · Cited by 17
Self-citation
Metadata
- Authors
- Yamanaka, H., Yamaoka, T., Mahara, A., Morimoto, N., & Suzuki, S.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2018-10
- Volume
- 179
- Pages
- 156-163
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2808554531
- Cited by
- 43
- References
- 1
- FWCI
- 5.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tissue-engineered submillimeter-diameter vascular grafts for free flap survival in rat model. https://app.cochat.ai/papers/10.1016/j.biomaterials.2018.06.022
- The paper
- Yamanaka, H., Yamaoka, T., Mahara, A., Morimoto, N., & Suzuki, S. (2018). Tissue-engineered submillimeter-diameter vascular grafts for free flap survival in rat model. Biomaterials. https://doi.org/10.1016/j.biomaterials.2018.06.022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.