Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 229

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Porous PEEK improves the bone-implant interface compared to plasma-sprayed titanium coating on PEEK

Torstrick, F. Brennan, Lin, Angela S.P., Potter, Daniel, Safranski, David L., Sulchek, Todd A., Gall, Ken, Guldberg, Robert E. · 2018 · Biomaterials

Abstract

Polyether-ether-ketone (PEEK) is one of the most common materials used for load-bearing orthopaedic devices due to its radiolucency and favorable mechanical properties. However, current smooth-surfaced PEEK implants can lead to fibrous encapsulation and poor osseointegration. This study compared the in vitro and in vivo bone response to two smooth PEEK alternatives: porous PEEK and plasma-sprayed titanium coatings on PEEK. MC3T3 cells were grown on smooth PEEK, porous PEEK, and Ti-coated PEEK for 14 days and assayed for calcium content, osteocalcin, VEGF and ALP activity. Osseointegration was investigated by implanting cylindrical implants into the proximal tibiae of male Sprague Dawley rats for 8 weeks. Bone-implant interfaces were evaluated using μCT, histology and pullout testing. Cells on porous PEEK surfaces produced more calcium, osteocalcin, and VEGF than smooth PEEK and Ti-coated PEEK groups. Bone ingrowth into porous PEEK surfaces was comparable to previously reported porous materials and correlated well between μCT and histology analysis. Porous PEEK implants exhibited greater pullout force, stiffness and energy-to-failure compared to smooth PEEK and Ti-coated PEEK, despite Ti-coated PEEK exhibiting a high degree of bone-implant contact. These results are attributed to increased mechanical interlocking of bone with the porous PEEK implant surface. Overall, porous PEEK was associated with improved osteogenic differentiation in vitro and greater implant fixation in vivo compared to smooth PEEK and Ti-coated PEEK. These results suggest that not all PEEK implants inherently generate a fibrous response and that topography has a central role in determining implant osseointegration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.biomaterials.2018.09.009

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 229

Metadata

Authors
Torstrick, F. B., Lin, A. S. P., Potter, D., Safranski, D. L., Sulchek, T. A., Gall, K., & Guldberg, R. E.
Venue
Biomaterials
Publisher
Elsevier BV
Published
2018-12
Volume
185
Pages
106-116
ISSN
0142-9612 (ISSN-L)
OpenAlex
W2889795645
Cited by
229
References
1
FWCI
7.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Porous PEEK improves the bone-implant interface compared to plasma-sprayed titanium coating on PEEK. https://app.cochat.ai/papers/10.1016/j.biomaterials.2018.09.009
The paper
Torstrick, F. B., Lin, A. S. P., Potter, D., Safranski, D. L., Sulchek, T. A., Gall, K., & Guldberg, R. E. (2018). Porous PEEK improves the bone-implant interface compared to plasma-sprayed titanium coating on PEEK. Biomaterials. https://doi.org/10.1016/j.biomaterials.2018.09.009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.