CoChat

High-purity weight-bearing magnesium screw: Translational application in the healing of femoral neck fracture

Huang, Shibo, Wang, Benjie, Zhang, Xiuzhi, Lu, Faqiang, Wang, Zongpu, Tian, Simiao, Li, Dongyi, Yang, Jiahui, Cao, Fang, Cheng, Liangliang, Gao, Ziqi, Li, Yangde, Qin, Kairong, Zhao, Dewei · 2020 · Biomaterials
Cited by 106

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Magnesium (Mg)-based metals can be used as next-generation fracture internal fixation devices due to their specific properties. We used vascularized bone grafting fixed by degradable pure Mg screws and obtained satisfactory results in the treatment of osteonecrosis of the femoral head. However, the mechanical properties of these screws make them weaker than those made of traditional metals. In particular, one of the main challenges of using screws made of Mg-based metals is their application in fixation at important weight-bearing sites in the human body. Femoral neck fracture is a common clinical injury. In this injury, the large bearing stress at the junction requires a fixation device with extremely high mechanical strength. Surgery and appropriate internal fixation can accelerate the healing of femoral neck fractures. Traditional internal fixation devices have some disadvantages after surgery, including stress shielding effects and the need for secondary surgery to remove screws. On the basis of previous work, we developed high-strength pure Mg screws for femoral neck fractures. In this study, we describe the first use of high-purity Mg to prepare large-size weight-bearing screws for the fixation of femoral neck fractures in goats. We then performed a 48 weeks follow-up study using in vivo transformation experiments. The results show that these biodegradable high-purity Mg weight-bearing screws had sufficient mechanical strength and a degradation rate compatible with bone repair. Furthermore, good bone formation was achieved during the degradation process and reconstruction of the bone tissue and blood supply of the femoral head and femoral neck. This study provides a basis for future research on the clinical transformation of biodegradable high-purity Mg weight-bearing screws.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.biomaterials.2020.119829

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 106

Metadata

Authors
Huang, S., Wang, B., Zhang, X., Lu, F., Wang, Z., Tian, S., Li, D., Yang, J., Cao, F., Cheng, L., Gao, Z., Li, Y., Qin, K., & Zhao, D.
Venue
Biomaterials
Publisher
Elsevier BV
Published
2020-04
Volume
238
Pages
119829
ISSN
0142-9612 (ISSN-L)
OpenAlex
W3004150573
Cited by
106
References
1
FWCI
3.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.