Cholesterol amperometric biosensor based on cytochrome P450scc
Open accessThe DOI matches its Crossref record.
Abstract
A screen-printed enzyme electrode based on flavocytochrome P450scc (RfP450scc) for amperometric determination of cholesterol has been developed. A one-step method for RfP450scc immobilization in the presence of glutaraldehyde or by entrapment of enzyme within a hydrogel of agarose is discussed. The sensitivity of the biosensor based on immobilization procedures of flavocytochrome P450scc by glutaric aldehyde is 13.8 nA microM(-1) and the detection limit is 300 microM with a coefficient of linearity 0.98 for cholesterol in the presence of sodium cholate as detergent. The detection limits and the sensitivity of the agarose-based electrode are 155 microM and 6.9 nA microM(-1) with a linearity coefficient of 0.99. For both types of electrodes, the amperometric response to cholesterol in the presence of detergent was rather quick (1.5-2 min).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Immobilization strategies to develop enzymatic biosensors
Sassolas, A., Blum, L. J., & Leca-Bouvier, B. D. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.09.003 · Cited by 1,130
Recent developments in the field of screen-printed electrodes and their related applications
Renedo, O. D., Alonso-Lomillo, M. A., & Martínez, M. J. A. (2007) · Talanta · doi:10.1016/j.talanta.2007.03.050 · Cited by 647
Hydrogel Based Sensors for Biomedical Applications: An Updated Review
Tavakoli, J., & Tang, Y. (2017) · Polymers · doi:10.3390/polym9080364 · Cited by 434
Electrochemical Sensors for Clinic Analysis
Wang, Y., Xu, H., Zhang, J., & Li, G. (2008) · Sensors · doi:10.3390/s8042043 · Cited by 398
Applications of polymers for biomolecule immobilization in electrochemical biosensors
Teles, F. R. R., & Fonseca, L. P. (2008) · Materials Science and Engineering: C · doi:10.1016/j.msec.2008.04.010 · Cited by 279
Metadata
- Authors
- Shumyantseva, V., Deluca, G., Bulko, T., Carrara, S., Nicolini, C., Usanov, S. A., & Archakov, A.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2004-04
- Volume
- 19
- Issue
- 9
- Pages
- 971-976
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W1974958087
- Cited by
- 86
- References
- 0
- FWCI
- 5.70
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cholesterol amperometric biosensor based on cytochrome P450scc. https://app.cochat.ai/papers/10.1016/j.bios.2003.09.001
- The paper
- Shumyantseva, V., Deluca, G., Bulko, T., Carrara, S., Nicolini, C., Usanov, S. A., & Archakov, A. (2004). Cholesterol amperometric biosensor based on cytochrome P450scc. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2003.09.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.