Use of hydrogel coating to improve the performance of implanted glucose sensors

Yu, Bazhang, Wang, Chunyan, Ju, Young Min, West, Leigh, Harmon, Julie, Moussy, Yvonne, Moussy, Francis·2008·Biosensors and Bioelectronics

Abstract

In order to protect implanted glucose sensors from biofouling, novel hydrogels (146-217% water by mass) were developed based on a copolymer of hydroxyethyl methacrylate (HEMA) and 2,3-dihydroxypropyl methacrylate (DHPMA). The porosity and mechanical properties of the hydrogels were improved using N-vinyl-2-pyrrolidinone (VP) and ethyleneglycol dimethacrylate (EGDMA). The results of SEM and DSC FT-IT analyses showed that the hydrogel (VP30) produced from a monomeric mixture of 34.5% HEMA, 34.5% DHPMA, 30% VP and 1% EDGMA (mol%) had an excellent pore structure, high water content at swelling equilibrium (W eq=166% by mass) and acceptable mechanical properties. Two kinds of VP30-coated sensors, Pt/GOx/VP30 and Pt/GOx/epoxy-polyurethane (EPU)/VP30 sensors were examined in glucose solutions during a period of 4 weeks. The Pt/GOx/VP30 sensors produced large response currents but the response linearity was poor. Therefore, further studies were focused on the Pt/GOx/EPU/VP30 sensors. With a diffusion-limiting epoxy-polyurethane membrane, the linearity was improved (2-30 mM) and the response time was within 5 min. Eight Pt/GOx/EPU/VP30 sensors were subcutaneously implanted in rats and tested once per week over 4 weeks. All of the implanted sensors kept functioning for at least 21 days and 3 out of 8 sensors still functioned at day 28. Histology revealed that the fibrous capsules surrounding hydrogel-coated sensors were thinner than those surrounding Pt/GOx/EPU sensors after 28 days of implantation.

Integrity signals

Registry

Crossref · 10.1016/j.bios.2007.11.010

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Hydrogel-coated biosensors were still functional after 21 days, whereas only 13.5% of controls were still functional.

    “Hydrogel-coated biosensors were still functional after 21 days whereas only 13.5% of the controls were still functional.147”
  • The longevity of hydrogel-coated biosensors was attributed to reduced fibrous encapsulation and immune cells adjacent to the hydrogel coating.

    “Their longevity was attributed to reduced fibrous encapsulation and immune cells adjacent to the hydrogel-coated as revealed by histological analysis of the surrounding tissue.147”
  • The accuracy of hydrogel-coated biosensors was not examined, so the impact of the hydrogel coating on accuracy remains unclear.

    “Even with these benefits, the accuracy was not examined and it is unclear what impact the hydrogel coating would provide in this respect.”

The citation lists haven’t been fetched yet

References 22 · Cited by 105

Authors
Yu, B., Wang, C., Ju, Y. M., West, L., Harmon, J., Moussy, Y., & Moussy, F.
Affiliations
University of South Florida (US)
Corresponding author
  • Moussy, Yvonne
  • Moussy, Francis
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2008-03
Volume
23
Issue
8
Pages
1278-1284
ISSN
0956-5663 (ISSN-L)
OpenAlex
W2079965274
Cited by
105
References
22
Citations by year
2026: 2 · 2025: 1 · 2024: 6 · 2023: 5 · 2022: 6 · 2021: 11 · 2020: 11 · 2019: 3 · 2018: 7 · 2017: 3 · 2016: 4 · 2015: 2 · 2014: 3 · 2013: 4 · 2012: 11
FWCI
6.30
Type
journal article
Language
en
Open access
closed
Locations
  • Biosensors and Bioelectronics (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of Biomedical Imaging and Bioengineering (R01EB001640)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Medicine › Hydrogels: synthesis, properties, applications
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
Keywords
hydrogel coating, biofouling, 2-hydroxyethyl methacrylate, N-vinylpyrrolidone, ethylene glycol dimethacrylate, polymer hydrogels, glucose oxidase, platinum electrode, subcutaneous implantation, fibrous capsule formation, sensor stability
MeSH terms
Animals, Electrochemistry, Equipment Design, Glucose, Microelectrodes, Sensitivity and Specificity, Biosensing Techniques, Equipment Failure Analysis, Prostheses and Implants, Coated Materials, Biocompatible, Hydrogels, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review