Biocompatible Materials for Continuous Glucose Monitoring Devices
Open accessAbstract
ADVERTISEMENT RETURN TO ISSUEPREVReviewNEXTBiocompatible Materials for Continuous Glucose Monitoring DevicesScott P. Nichols†, Ahyeon Koh†, Wesley L. Storm†, Jae Ho Shin‡, and Mark H. Schoenfisch*†View Author Information† Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States‡ Department of Chemistry, Kwangwoon University, Seoul, Korea*Address: Chemistry Department of Chemistry, University of North Carolina at Chapel Hill, CB#3290, Chapel Hill, North Carolina, 27599, USA. Tel: +1 (919) 843-8714. Fax: +1 (919) 962-2388. E-mail: [email protected]Cite this: Chem. Rev. 2013, 113, 4, 2528–2549Publication Date (Web):February 7, 2013Publication History Received19 September 2012Published online7 February 2013Published inissue 10 April 2013https://pubs.acs.org/doi/10.1021/cr300387jhttps://doi.org/10.1021/cr300387jreview-articleACS PublicationsCopyright © 2013 American Chemical SocietyRequest reuse permissionsArticle Views8353Altmetric-Citations268LEARN ABOUT THESE METRICSArticle Views are the COUNTER-compliant sum of full text article downloads since November 2008 (both PDF and HTML) across all institutions and individuals. These metrics are regularly updated to reflect usage leading up to the last few days.Citations are the number of other articles citing this article, calculated by Crossref and updated daily. Find more information about Crossref citation counts.The Altmetric Attention Score is a quantitative measure of the attention that a research article has received online. Clicking on the donut icon will load a page at altmetric.com with additional details about the score and the social media presence for the given article. Find more information on the Altmetric Attention Score and how the score is calculated. Share Add toView InAdd Full Text with ReferenceAdd Description ExportRISCitationCitation and abstractCitation and referencesMore Options Share onFacebookTwitterWechatLinked InRedditEmail Other access optionsGet e-Alertsclose SUBJECTS:Anatomy,Carbohydrates,Inflammation,Peptides and proteins,Sensors Get e-Alerts
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
0 of 236 cited sources checked · 0 supported · 0 flagged
- Premisecitation
Near-infrared spectroscopy allows 90-95% of light to pass through the stratum corneum and epidermis into subcutaneous space with minimal tissue adsorption independent of skin pigmentation.
“Optical detection of glucose via near infrared (NIR) spectroscopy enables 90–95% of the light to pass through the human stratum corneum and epidermis into subcutaneous space with minimal tissue adsorption independent of skin pigmentation.19,40–41”
Quote in the paperNot a substantial claim0 of 3 sources checked - Premisecitation
CGM supplies real-time data on glucose trends, magnitude, duration, and frequency of daily fluctuations.
“Continuous glucose monitoring (CGM) provides real-time information on trends (i.e., whether the glucose levels are increasing or decreasing), magnitude, duration, and frequency of glucose fluctuations during the day.5–6”
Quote in the paperSubstantial claim0 of 2 sources checked - Premisecitation
A subcutaneous sensor using differential oxygen detection with glucose oxidase and catalase achieved accurate glucose measurements for more than one year by correcting for oxygen reduction differences.
“Accurate glucose measurements were carried out for >1 year by taking into account the difference in oxygen reduction at an electrode producing a glucose-modulated current and a reference electrode producing an oxygen-dependent current.31”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [31] Gough D. A., 2010, Sci. Transl. Med. source
Not checked in the free run.
- Premisereasoning
Percutaneous sensors require frequent calibration, about twice daily, even after stabilization because sensor response changes.
“Frequent calibration (e.g., 2 times per day) is required even after the stabilization period due to changes in sensor response.”
Quote in the paperNot a substantial claim - Interpretationcitation
The subcutaneous nature of fully implanted sensors likely reduced micromotion effects associated with the foreign body response.
“The subcutaneous nature of the sensors likely minimized any micromotion effects associated with the foreign body response.32”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [32] Helton K. L., 2011, J. Diabetes Sci. Technol. source
Not checked in the free run.
- Premisecitation
Electrochemical biosensors are among the most studied CGM devices because they can be miniaturized and give high selectivity and sensitivity via immobilized enzyme reactions.
“Due to their ability to be miniaturized and give high selectivity and sensitivity governed by the specific biocatalytic reactions of an immobilized enzyme, electrochemical biosensors are among the most widely studied devices.4”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [4] Wang J., 2008, Chem. Rev. source
Not checked in the free run.
- Premisecitation
Electron mediators can reduce the impact of interfering species by lowering the working potential needed to oxidize hydrogen peroxide.
“As described earlier, the use of mediators to shuttle electrons between the enzyme and the electrode can also minimize the impact of interfering species by lowering the working potential required to oxidize hydrogen peroxide.56,58,62”
Quote in the paperNot a substantial claim0 of 3 sources checked - Interpretationreasoning
A one-point calibration is considered more appropriate than a two-point calibration.
“A one-point calibration is thus considered more appropriate.”
Quote in the paperNot a substantial claim - Premisecitation
Deactivation by endogenously produced hydrogen peroxide from oxidase reactions also contributes to loss of enzyme activity.
“However, deactivation by endogenously produced hydrogen peroxide from oxidase reactions also contributes to the loss of activity.71”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [71] Tse P. H. S., 1987, Biotechnol. Bioeng. source
Not checked in the free run.
- Interpretationnone given
Sensor performance issues from changing oxygen levels are exacerbated by the foreign body response, which causes local consumption of oxygen and glucose by inflammatory cells near the sensor.
“Sensor performance issues due to changing oxygen levels are exacerbated due to the foreign body response that results in local consumption of oxygen and glucose by inflammatory cells at the vicinity of the sensor.”
Quote in the paperNot a substantial claim - Interpretationnone given
Patient variability is an equally important factor for CGM device utility.
“In addition to the inherent sensor fabrication and analytical measurement challenges, patient variability is an equally important factor for CGM device utility.”
Quote in the paperNot a substantial claim - Premisecitation
Sensor films and membranes are prone to degradation from oxidative challenges, calcification, and delamination.
“These materials are prone to degradation from oxidative challenges (i.e., foreign body response), calcification, and delamination.73”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [73] Zhao Q., 1991, J. Biomed. Mater. Res. source
Not checked in the free run.
- Premisecitation
The erratic outputs with posture changes were attributed in part to blood occlusion from pressures applied to tissue adjacent to the sensor.
“Such behavior was attributed in part to blood occlusion due to pressures applied to tissue adjacent to the sensor.86–87”
Quote in the paperSubstantial claim0 of 2 sources checked - Premisenone given
Frequent calibration using finger-prick glucose monitoring is still required for commercial CGM sensors because of erratic analytical performance.
“Additionally, frequent calibration using intermittent glucose monitoring (via finger pricks) is still required due to erratic analytical performance.”
Quote in the paperNot a substantial claim - Premisecitation
Temperature fluctuations in subcutaneous tissue impact sensor performance by altering glucose oxidase activity.
“Temperature fluctuations in subcutaneous tissue will also impact sensor performance by altering glucose oxidase activity.61”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [61] Myrer J. W., 1997, J. Athletic Training
Not checked in the free run.
- Premisecitation
Permselective membranes using size exclusion and/or electrostatic repulsion are often used to improve glucose selectivity.
“Permselective membranes via size exclusion and/or electrostatic repulsion are often used to improve selectivity.4”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [4] Wang J., 2008, Chem. Rev. source
Not checked in the free run.
- Interpretationnone given
The foreign body response impacts the bioanalytical and clinical utility of CGM devices more than other design, fabrication, and use criteria.
“While the above design, fabrication, and use criteria are of importance to CGM device use, none impacts the bioanalytical and clinical utility as much as the foreign body response (FBR).”
Quote in the paperSubstantial claim - Interpretationcitation
External pressure on a CGM sensor is a valid threat to analytical performance.
“External pressure on the CGM sensor has also become a valid threat to analytical performance.”
Quote in the paperSubstantial claim - Interpretationreasoning
Tissue heterogeneity affects the analytical performance of percutaneous CGM sensors because they are implanted through the epidermis, dermis, and subcutaneous layers.
“Since percutaneous sensors are implanted through the epidermis, dermis, and subcutaneous layers, the effects of tissue heterogeneity are relevant to the analytical performance of the sensor.”
Quote in the paperNot a substantial claim - Premisecitation
Oxygen diffusion to the sensor decays exponentially after implantation because of changes in tissue permeability.
“Of note, the oxygen diffusion to the sensor decays exponentially after sensor implantation due to changes in tissue permeability.31”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [31] Gough D. A., 2010, Sci. Transl. Med. source
Not checked in the free run.
- Premisecitation
Clinical use of a SERS biosensor would require implantation that could cause photothermal damage to nearby tissue from constant laser irradiation.
“Clinical implementation of a SERS biosensor would require implantation of a device that could lead to photothermal damage of nearby tissue due to constant irradiation by the laser source.30”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [30] Vashist S. K., 2012, Anal. Chim. Acta source
Not checked in the free run.
- Premisecitation
The lag time between blood and subcutaneous tissue glucose concentrations causes further inaccuracies for CGM devices.
“The lag time between blood and subcutaneous tissue glucose concentrations cause further inaccuracies for CGM devices.79–80”
Quote in the paperNot a substantial claim0 of 2 sources checked - Premisecitation
The ratio of blood to tissue glucose is not constant and depends on metabolic rates related to glucose and insulin physiology, including cellular glucose uptake, blood flow, and capillary permeability.
“This assumption is problematic because the ratio of blood/tissue glucose is not constant, but rather depends on the metabolic rates related to glucose and insulin physiology including glucose uptake by cells or from blood vessels, blood flow, and permeability of capillaries.78”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [78] Cengiz E., 2009, Diabetes Technol. Ther. source
Not checked in the free run.
- Premisereasoning
Interfering species such as acetaminophen, ascorbic acid, and uric acid affect sensor response because they are electroactive at the potential used to oxidize hydrogen peroxide.
“Indeed, a number of interferences (e.g., acetaminophen, ascorbic acid, and uric acid) can affect sensor response as they are electroactive at the electrode potential used to oxidize hydrogen peroxide.”
Quote in the paperNot a substantial claim - Premisecitation
Low oxygen concentrations cause problems with biosensor response to glucose, particularly dynamic range, due to stoichiometric imbalance between oxygen and glucose.
“Indeed, low concentrations of oxygen lead to problems with the biosensor response to glucose (particularly dynamic range) due to stoichiometric imbalance between the two cofactors.19,63”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [19] Vaddiraju S., 2010, J. Diabetes Sci. Technol. source
Not checked in the free run.
- cites [63] Wilson G. S., 2009
Not checked in the free run.
- Premisenone given
In vivo failure of sensor components can be categorized as enzyme instability and leaching, membrane degradation and delamination, and electrode passivation.
“The failure of sensor components in vivo may be categorized as follows: 1) enzyme instability and leaching; 2) membrane degradation and delamination; and, 3) electrode passivation.”
Quote in the paperNot a substantial claim - Premisecitation
Enzyme activity in glucose sensors begins to decrease immediately due to polymer entrapment and exposure to reactive oxidative species from sensor operation and the foreign body response.
“Enzyme activity begins to decrease immediately both due to polymer entrapment and exposure to reactive oxidative species from sensor operation and the FBR (exposure to hydrogen peroxide and other reactive radicals).71–72”
Quote in the paperSubstantial claim0 of 2 sources checked - Premisenone given
Even properly immobilized enzymes inherently lose activity over time, primarily because non-covalently bonded FAD cofactor is lost.
“Nevertheless, even properly immobilized enzymes inherently lose activity over time due primarily to loss of non-covalently bonded FAD cofactor.”
Quote in the paperNot a substantial claim - Premisereasoning
Longer or unpredictable lag times are created by physiological differences between individuals, intrinsic sensor lag time, and noise filtering.
“Longer, or unpredictable, lag times are created by physiological differences between individuals, intrinsic sensor lag time (typically on the order of seconds to a few minutes), and noise filtering.”
Quote in the paperNot a substantial claim - Premisecitation
Polyphenol permselective membranes can be electropolymerized within an enzyme layer controllably, yielding a self-limiting thickness of 10-100 nm.
“Polyphenol permselective membranes are able to electropolymerize within an enzyme layer in a controllable manner, yielding a film with a thickness that is self-limiting (10–100 nm).”
Quote in the paperNot a substantial claim0 of 2 sources checked - Premisecitation
Under normal conditions, the physiological lag time between blood and interstitial fluid glucose is between 5 and 10 minutes.
“Under normal conditions (i.e., conditions in which glucose levels are not rapidly changing from activities such as exercising or eating), the physiological lag time between blood and interstitial fluid glucose ranges between 5 and 10 min.78,81”
Quote in the paperNot a substantial claim0 of 2 sources checked - Premisecitation
Some permselective membranes exclude surface-active macromolecules such as proteins and platelets, protecting the surface from biofouling.
“In some cases, such membranes also exclude surface-active macromolecules (i.e., proteins and platelets), protecting the surface from biofouling.61”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [61] Myrer J. W., 1997, J. Athletic Training
Not checked in the free run.
- Premisecitation
Lag is also created by tissue responses to the sensor such as electrode fouling, biofouling, and foreign body encapsulation that impedes glucose diffusion.
“Lag is also created by tissue responses to the sensor such as electrode fouling, biofouling, and the foreign body encapsulation that impedes glucose diffusion to the sensor.5–6”
Quote in the paperNot a substantial claim0 of 2 sources checked - Premisecitation
Many reports in the literature neglect selectivity for glucose over interfering species during sensor characterization.
“Although sensor accuracy is critical for compliance, many reports in the literature often neglect selectivity for glucose over interfering species during characterization.54”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [54] Klonoff, D.; Bernhardt, P.; Ginsberg, B. H.; Joseph, J.; Mastrototaro, J.; Parker, D. R.; Vesper, H.; Vigersky, R.Performance Metrics for Continuous Interstitial Glucose Monitoring; Approved Guideline;Clinical and Laboratory Standards Institute:Wayne, PA, 2008.
Not checked in the free run.
- Interpretationreasoning
The composition of permselective membranes must be considered for biocompatibility because the polymer contacts tissue and may dictate the foreign body response.
“The composition of such membranes must be accounted for when considering biocompatibility as the polymer contacts tissue and may ultimately dictate the foreign body response (FBR).”
Quote in the paperNot a substantial claim - Premisecitation
In mast cell-sufficient mice, glucose sensor performance was erratic, with temporary response loss during the first 3 weeks of a 28-day implantation.
“glucose sensor performance in mast cell-sufficient mice was erratic with temporary response loss occurring within the first 3 weeks.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [106] Klueh U., 2010, Biomaterials source
Not checked in the free run.
- Premisecitation
The biofouling observed had only relatively small direct effects on overall resistance and glucose extraction efficiency.
“The observed biofouling was found to have only relatively small direct effects on the overall resistance and glucose extraction efficiency.104”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [104] Wisniewski N., 2001, J. Biomed. Mater. Res. source
Not checked in the free run.
- Premisecitation
Most long-term medical implants are considered biocompatible or inert once the foreign body response resolves and the device is encapsulated by a collagen layer.
“Most long-term medical implants to date are considered biocompatible or inert once the FBR resolves and the device is encapsulated by a collagen layer.89”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [89] Ratner B. D., 2007, Polym. Int. source
Not checked in the free run.
- Interpretationreasoning
Because blood vessels are the primary source of glucose, collagen encapsulation hinders accurate blood glucose measurements.
“As blood vessels are the primary source of glucose, such encapsulation hinders accurate measurements of blood glucose.”
Quote in the paperSubstantial claim - Premisecitation
Vessel length and perfusion of the vasculature increased during the 14-day implantation period.
“The vessel length and perfusion of the vasculature increased during the implantation period (i.e., 14 d).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [109] Koschwanez H. E., 2010, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
- Interpretationcitation
These results indicate a link between mast cell action and erratic glucose sensor performance.
“further indicating a link between mast cell action and erratic glucose sensor performance.106”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [106] Klueh U., 2010, Biomaterials source
Not checked in the free run.
- Premisecitation
Proteins instantaneously adhere to the biomaterial surface in a process called biofouling.
“Instantaneously, proteins adhere to the biomaterial surface in a process referred to as biofouling.91–92”
Quote in the paperNot a substantial claim0 of 2 sources checked - Premisecitation
For microdialysis probes, tissue-caused resistance to glucose mass transfer over 3 h and 8 d implantation was typically 3 to 5 times greater than biofouling-caused resistance, regardless of implantation period.
“the resistance to mass transfer of analyte (i.e., glucose) caused by the tissue over both short- (3 h) and long-term (8 d) implantation periods were typically 3 to 5 times greater than that caused by biofouling of the probes, regardless of implantation period.104”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [104] Wisniewski N., 2001, J. Biomed. Mater. Res. source
Not checked in the free run.
- Interpretationreasoning
The activation state (M1 or M2) of macrophages may influence the overall foreign body response.
“While preventing all macrophage migration and subsequent phagocytosis at a wound (glucose sensor) is unlikely, the activation state (i.e., M1 or M2) of the macrophage may influence the overall FBR.”
Quote in the paperNot a substantial claim - Interpretationcitation
Angiogenesis is not the only factor in assessing the biocompatibility of CGM sensors.
“indicating that angiogenesis is not the only factor in assessing the biocompatibility of CGM sensors.109”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [109] Koschwanez H. E., 2010, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
- Premisecitation
The foreign body response initiates upon insertion of almost any material into subcutaneous tissue, starting with wound creation and the wound healing cascade.
“As shown in Figure 2, the FBR initiates upon the insertion of almost any material into subcutaneous tissue, starting with the creation of a wound and the wound healing cascade.90–91”
Quote in the paperSubstantial claim0 of 2 sources checked - Premisecitation
Macrophages, monocytes, mast cells, and fibroblasts are recruited to the implant site to initiate clearance of the foreign body by releasing chemokines and cytokines.
“As part of the FBR, macrophages, monocytes, mast cells, and fibroblasts are recruited to the implant site to initiate clearance of the foreign body by releasing chemokines and cytokines.90–91”
Quote in the paperNot a substantial claim0 of 2 sources checked - Premisecitation
Wisniewski et al. found that biofouling had only minimal effects on microdialysis probes.
“found biofouling effects to actually be minimal.104”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [104] Wisniewski N., 2001, J. Biomed. Mater. Res. source
Not checked in the free run.
- Premisecitation
Glucose sensitivity correlated with collagen encapsulation of the sponges, with thicker collagen producing greater sensitivity loss.
“Glucose sensitivity correlated well with the collagen encapsulation of the sponges with thicker collagen resulting in greater sensitivity loss.108”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [108] Dungel P., 2008, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
- Premisecitation
The concentrations and types of mediators released elicit further cell recruitment and ultimately phagocytosis.
“The concentrations and types of mediators released elicit further cell recruitment and ultimately phagocytosis93 as the body attempts to digest the implant.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [93] Luttikhuizen D. T., 2006, Tissue Eng. source
Not checked in the free run.
- Premisecitation
Initial protein adsorption is an integral part of the foreign body response because the ensuing interface promotes adhesion of inflammatory cells that stimulate blood clotting and development of a provisional matrix.
“The initial protein adsorption is an integral part of the overall FBR as the ensuing interface promotes the adhesion of inflammatory cells that subsequently stimulate blood clotting and the development of a provisional matrix.92”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [92] Wilson C. J., 2005, Tissue Eng. source
Not checked in the free run.
- Premisenone given
After one to two weeks, inflammatory cells deposit a collagen matrix that sequesters the implant from native tissue.
“After one to two weeks, inflammatory cells deposit a collagen matrix that sequesters the implant from the native tissue.”
Quote in the paperSubstantial claim - Premisecitation
Histology confirmed that mast cell-deficient mice had less fibrosis and inflammation at the implantation site.
“Histology samples from both experimental groups confirmed that the mast cell-deficient mice exhibited reduced fibrosis and inflammation at the implantation site.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [106] Klueh U., 2010, Biomaterials source
Not checked in the free run.
- Premisecitation
Most biofouling proteins on the sensor membrane were fragments smaller than 15 kDa.
“the majority of the biofouling proteins on the sensor membrane were fragments <15 kDa.102–103”
Quote in the paperNot a substantial claim0 of 2 sources checked - Premisecitation
Foreign body giant cell formation on polyurethanes promotes cracking of the underlying biomaterial.
“For example, FBGC formation on polyurethanes has been shown to promote cracking of the underlying biomaterial.73”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [73] Zhao Q., 1991, J. Biomed. Mater. Res. source
Not checked in the free run.
- Premisecitation
Adhesion of proteins and cells to a glucose sensor at the outset reduces the sensor's performance.
“the initial adhesion of proteins and cells onto a glucose sensor dampens sensor performance.100–101”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [100] Thomé-Duret V., 1996, Diabetes Metab.
Not checked in the free run.
- cites [101] Gerritsen M., 2001, J. Biomed. Mater. Res. source
Not checked in the free run.
- Premisecitation
In Thomé-Duret et al.'s study, polyurethane-coated glucose biosensors tested immediately after explantation had glucose sensitivities comparable to those measured in vivo.
“While the immediately explanted sensors had glucose sensitivities similar to those analyzed in vivo”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [100] Thomé-Duret V., 1996, Diabetes Metab.
Not checked in the free run.
- Premisecitation
Despite increased vasculature, sensor sensitivity did not increase.
“Despite such increases in vasculature, the sensitivity of the sensor did not increase”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [109] Koschwanez H. E., 2010, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
- Interpretationreasoning
CGM devices undergo a similar fate to other implants, but the combination of the foreign body response, oxygen and glucose availability, and need for immediate calibration and use has significantly impeded their utility and implementation for diabetes management.
“Although CGM devices have a similar fate, the combination of the FBR, oxygen and glucose availability, and need for immediate calibration and use (e.g., in the physician’s office), have significantly impeded their utility and implementation as effective devices for diabetes management.”
Quote in the paperSubstantial claim - Premisecitation
As the foreign body response progresses, frustrated phagocytosis from activated macrophages leads to fusion into foreign body giant cells that attempt to further break down the implant.
“As the FBR progresses, frustrated phagocytosis from activated macrophages will lead to the fusion of macrophages into foreign body giant cells (FBGCs) that attempt to further breakdown the implant.73,94,97–98”
Quote in the paperSubstantial claim0 of 4 sources checked- cites [73] Zhao Q., 1991, J. Biomed. Mater. Res. source
Not checked in the free run.
- cites [94] Zhao Q. H., 1993, J. Biomed. Mater. Res. source
Not checked in the free run.
- cites [97] Anderson J. M., 1999, J. Mater. Sci.-Mater. Med. source
Not checked in the free run.
- cites [98] Kao W. Y. J., 1994, J. Biomed. Mater. Res. source
Not checked in the free run.
- Premisecitation
Fluorescein diffusion through explanted collagen capsules was about 50% of that through normal subcutaneous tissue.
“Diffusion of the fluorescein through the explanted capsules was ~50% that of normal (i.e., subcutaneous) tissue.107”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [107] Sharkawy A. A., 1997, J. Biomed. Mater. Res. source
Not checked in the free run.
- Premisecitation
The collagen encapsulation lacks the microvasculature of native tissue.
“This collagen encapsulation lacks the microvasculature of native tissue.99”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [99] Sieminski A. L., 2000, Biomaterials source
Not checked in the free run.
- Interpretationnone given
The extent of capsule development depends on preceding foreign body response components, including protein adhesion, cell activation, and cytokine signaling.
“The extent of capsule development is dependent on all other preceding components of the FBR, including protein adhesion, cell activation, and cytokine signaling.”
Quote in the paperSubstantial claim - Interpretationreasoning
The optical window technique is highly invasive because it requires implanting additional materials that elicit an additional tissue reaction and influence the overall FBR to the nearby biomaterial.
“this technique is highly invasive involving implantation of additional materials (i.e., an optical window) that inherently elicits an additional tissue reaction with influence on the overall FBR to the closely placed biomaterial.”
Quote in the paperNot a substantial claim - Premisecitation
In vitro test outcomes are not an accurate predictor of biocompatibility or glucose sensor performance in vivo.
“their outcomes are not an accurate predictor of biocompatibility or glucose sensor performance in vivo.70,112”
Quote in the paperSubstantial claim0 of 2 sources checked - Premisecitation
Diabetics typically have delayed and diminished wound healing.
“Diabetics typically suffer from delayed and diminished wound healing.127”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [127] Blakytny R., 2006, Diabetic Med. source
Not checked in the free run.
- Premisecitation
The wide range of available diabetic animal models may complicate comparisons between studies.
“the wide range of available diabetic models in animals (e.g., genetic or chemically induced) may further complicate comparisons between studies.129”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [129] Le N. N., 2011, J. Diabetes Sci. Technol. source
Not checked in the free run.
- Interpretationcitation
These histological differences could influence glucose sensor performance.
“that clearly could influence glucose sensor performance.128”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [128] Gerritsen H., 2000, J. Biomed. Mater. Res. source
Not checked in the free run.
- Interpretationreasoning
Testing in animal models is necessary to evaluate the intricate tissue reactions to a proposed biomaterial and to fully represent FBR complexity.
“testing in animal models is necessary to evaluate the intricate tissue reactions that confront a proposed biomaterial and fully represent FBR complexity.”
Quote in the paperSubstantial claim - Interpretationreasoning
The cage implant does not provide a complete analysis of the FBR because it yields no information on collagen capsule formation, capillary density in surrounding tissue, or sensor performance.
“it does not offer a complete analysis of the FBR as no information is gained with respect to collagen capsule formation, capillary density in the surrounding tissue, or sensor performance.”
Quote in the paperNot a substantial claim - Premisecitation
Capsule thickness was about 20% thinner around the smaller implant (300 versus 2000 μm thick) at 7 weeks.
“the capsule thickness was ~20% thinner surrounding the smaller implant.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [115] Ward W. K., 2002, Biomaterials source
Not checked in the free run.
- Premisecitation
Subcutaneous histology of a porous PLLA coating showed a threefold increase in vascularization and about a 65% reduction in collagen compared with bare glucose sensors at 3 weeks.
“Subcutaneous histology of a porous poly-L-lactic acid (PLLA) coating showed a threefold increase in vascularization and a ~65% reduction in collagen compared to bare glucose sensors at 3 weeks.121”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [121] Koschwanez H. E., 2008, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
- Premisecitation
At 10 and 14 days after implantation, vessel lengths and blood perfusion of porous materials were significantly greater than bare sensor coatings when implanted subcutaneously.
“At 10 and 14 d post-implantation, the vessel lengths and blood perfusion of the porous materials was significantly greater than bare (i.e., non-porous) sensor coatings when implanted subcutaneously.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [109] Koschwanez H. E., 2010, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
- Premisecitation
Implant location within the subcutaneous tissue affects the FBR.
“Picha et al. found that implant location within the subcutaneous tissue affects the FBR.132”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [132] Picha G. J., 1996, J. Biomed. Mater. Res. source
Not checked in the free run.
- Premisecitation
This reduction was explained by clot formation around the sensing portion of the CGM device, which formed a glucose sink until clearance.
“This reduction was explained by the clot formation around the sensing portion of the CGM device that formed a glucose sink until clearance.133”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [133] Klueh U., 2011, J. Diabetes Sci. Technol. source
Not checked in the free run.
- Interpretationcitation
Sensor geometry may be an important factor in determining biocompatibility.
“this study demonstrates that sensor geometry may be an important factor in determining biocompatibility.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [130] Li D. J., 1999, J. Biomed. Mater. Res. source
Not checked in the free run.
- Interpretationreasoning
The optical window technique is likely not an accurate characterization of sensor performance or the FBR.
“As such, it is likely not an accurate characterization of sensor performance or the FBR.”
Quote in the paperSubstantial claim - Premisecitation
The cage implant allows examination of the inflammatory response to a substrate over time.
“the cage implant allows for the examination of the inflammatory response to a substrate of interest over time.113”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [113] Marchant R., 1983, J. Biomed. Mater. Res. source
Not checked in the free run.
- Premisecitation
Injection of blood, but not saline or plasma, led to a temporary signal reduction lasting several hours that eventually returned to normal.
“the injection of blood, but not saline or plasma, led to a temporary (i.e., several hours) signal reduction that eventually returned to normal.133”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [133] Klueh U., 2011, J. Diabetes Sci. Technol. source
Not checked in the free run.
- Premisecitation
The ratio of dialysate glucose to blood glucose was significantly different between rats and humans, indicating differences in relative glucose availability in tissue surrounding an implanted device.
“the ratio of the glucose concentration in the dialysate to that in blood were significantly different between rats and humans indicating differences in the relative glucose availability in the tissue surrounding an implanted device.126”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [126] Wisniewski N., 2002, Am. J. Physiol.-Endocrinol. Metab source
Not checked in the free run.
- Premisecitation
Dialysate concentrations of glucose, pyruvate, lactate, glycerol, and urea at a microdialysis probe-tissue interface were significantly different between rats and humans throughout the first 6 days, except for glycerol on day 0.
“The dialysate concentrations were significantly different for all metabolites in rats and humans throughout the first 6 days of the experiment, with the exception of glycerol on day 0.126”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [126] Wisniewski N., 2002, Am. J. Physiol.-Endocrinol. Metab source
Not checked in the free run.
- Premisecitation
The same materials implanted percutaneously produced no observable differences.
“Despite these observations, the same materials implanted percutaneously resulted in no observable differences.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [109] Koschwanez H. E., 2010, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
- Premisecitation
In Novak and coworkers' model, changes in cellular glucose uptake and the capsule diffusion coefficient of glucose had little effect on simulated sensor performance.
“Changes in cellular glucose uptake and the capsule diffusion coefficient of glucose had little effect on simulated sensor performance.111”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [111] Novak M. T., 2010, Anal. Bioanal. Chem. source
Not checked in the free run.
- Interpretationcitation
The positive correlation between lag time and capsule thickness supported the models described above.
“The positive correlation between lag time and capsule thickness supported the models described above.107,110–111”
Quote in the paperSubstantial claim0 of 3 sources checked - Premisecitation
The two greatest factors in reducing sensor attenuation were low capsule density and a high degree of angiogenesis.
“The two greatest factors in reducing sensor attenuation were a low capsule density and high degree of angiogenesis.111”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [111] Novak M. T., 2010, Anal. Bioanal. Chem. source
Not checked in the free run.
- Premisecitation
The breakdown of Nafion membranes was likely caused by mineralization.
“Later studies by Mercado and Moussy demonstrated that this breakdown was likely caused by mineralization of the membrane.135”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [135] Mercado R. C., 1998, Biosens. Bioelectron. source
Not checked in the free run.
- Premisecitation
The sensors accurately tracked glucose with relatively short lag times of about 4.5 min.
“The sensors were found to accurately track the glucose with relatively short lag times (~4.5 min).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [137] Ward W. K., 2002, Biosens. Bioelectron. source
Not checked in the free run.
- Interpretationcitation
A pore size on the order of cellular dimensions was optimal for minimizing the FBR.
“again indicating that a pore size on the order of cellular dimensions was optimal for minimizing the FBR.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [153] Sharkawy A. A., 1998, J. Biomed. Mater. Res. source
Not checked in the free run.
- Interpretationreasoning
The pro-angiogenic properties previously reported for smaller or larger pore-sized materials might be due to their polydispersity.
“Based on the results of this study, the pro-angiogenic properties reported previously with either smaller or larger pore-sized materials might be the consequence of their polydispersity.”
Quote in the paperSubstantial claim - Interpretationcitation
Micromotion effects overrode the benefits of porosity because of the continual movement of the percutaneously implanted sensor in the tissue.
“These effects overrode the benefits of porosity due to the continual movement of the percutaneously implanted sensor in the tissue.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [121] Koschwanez H. E., 2008, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
- Premisecitation
Despite the histological benefits, the analytical performance of control sensors lacking collagen was better than that of collagen-based sensors.
“Despite the observed histological benefits, the analytical performance of control sensors (i.e., lacking collagen) was better than that of the collagen-based sensors.148”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [148] Ju Y. M., 2010, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
- Interpretationcitation
Incorporating strategies that reduce micromotion may be critical to fully realize the potential of porous membranes on percutaneous sensors.
“Thus, incorporating strategies that reduced the effects of micromotion may be critical to fully realize the potential of porous membranes on percutaneous sensors.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [121] Koschwanez H. E., 2008, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
- Interpretationreasoning
The body ultimately overwhelms the interface with protein and cell adsorption, producing an equally non-native surface.
“the body ultimately overwhelms the interface with protein and cell adsorption, resulting in an equally non-native surface.”
Quote in the paperSubstantial claim - Premisecitation
The diffusion coefficient of fluorescein through surrounding explanted tissue was about two times greater adjacent to porous PVA than to non-porous PVA.
“the diffusion coefficient of fluorescein through the surrounding explanted tissue was measured and determined to be approximately two times greater adjacent to porous versus non-porous PVA.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [107] Sharkawy A. A., 1997, J. Biomed. Mater. Res. source
Not checked in the free run.
- Premisecitation
The longevity of hydrogel-coated biosensors was attributed to reduced fibrous encapsulation and immune cells adjacent to the hydrogel coating.
“Their longevity was attributed to reduced fibrous encapsulation and immune cells adjacent to the hydrogel-coated as revealed by histological analysis of the surrounding tissue.147”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [147] Yu B. Z., 2008, Biosens. Bioelectron. source
Not checked in the free run.
- Premisecitation
Cao et al. reported decreased collagen capsule thickness for polycaprolactone fibers when aligned (~5-fold reduction) or random (~9-fold reduction) compared to solid films of the same polymer.
“Cao et al. reported a decrease in collagen capsule thickness for polycaprolactone fibers when their orientation was either aligned (~5 fold reduction) or random (~9 fold reduction) compared to solid films made from the same polymer.”
Quote in the paperSubstantial claim - Premisecitation
Ratner and coworkers fabricated porous materials with high precision in pore size (±5%) and connectivity.
“Ratner and coworkers have fabricated porous materials with high precision both in terms of size (±5%) and connectivity.157–158”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [157] Marshall A. J., 2004, ACS Polym. Prepr.
Not checked in the free run.
- cites [158] Ratner B. D., 2009, ACS Polym. Prepr.
Not checked in the free run.
- Premisecitation
Membranes with larger pores also showed increased vascularization at one year.
“The membranes with the larger pores also showed increased vascularization at the one year mark.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [155] Brauker J. H., 1995, J. Biomed. Mater. Res. source
Not checked in the free run.
- Premisecitation
Four of the five sensors failed to produce analytically useful data because of electronic failure or lack of integration into the surrounding tissue.
“However, four of the five sensors failed to produce analytically useful data due to either electronic failure or a lack of integration into the surrounding tissue.85”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [85] Gilligan B. C., 2004, Diabetes Technol. Ther. source
Not checked in the free run.
- Premisecitation
The difference in performance between the two implant modes was attributed to micromotion.
“The difference in performance between the two implant modes was attributed by the authors to micromotion.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [121] Koschwanez H. E., 2008, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
- Premisenone given
Polymer foams and salt-templated porous materials generally have broad pore size distributions.
“The porous materials described above (i.e., polymer foams and salt-templated polymers) are generally characterized as having broad distributions in pore size.”
Quote in the paperSubstantial claim - Premisereasoning
The specific pore sizes required for optimal tissue integration are not known.
“details about the specific pore sizes needed for optimum tissue integration are lacking..”
Quote in the paperSubstantial claim - Premisecitation
The alignment and orientation of electrospun fibers modulate the foreign body response.
“The alignment and orientation of the electrospun fibers also modulate the FBR.”
Quote in the paperSubstantial claim - Premisecitation
Substrates with a hydrogel coating had markedly less fibrous encapsulation than controls after 3 days.
“substrates with the hydrogel coating had markedly less fibrous encapsulation relative to controls.143”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [143] Quinn C. P., 1995, Biomaterials source
Not checked in the free run.
- Premisecitation
Coatings on percutaneous sensors did not produce similar histological or sensor performance improvements compared with bare sensors.
“However, coatings on percutaneous sensors did not lead to similar histological or sensor performance improvements versus control (i.e., bare) sensors.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [121] Koschwanez H. E., 2008, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
- Premisereasoning
Macrophages on non-porous implants were more likely to be in the inflammatory phenotype.
“In contrast, macrophages on non-porous implants were more likely to be in the inflammatory phenotype.”
Quote in the paperSubstantial claim - Premisecitation
Membranes with larger pores (5.0 versus 0.02 μm) had 80-100 times greater vascularization in the surrounding tissue.
“Membranes fabricated with the larger pores were characterized by 80–100x greater vascularization in the tissue surrounding the implant.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [155] Brauker J. H., 1995, J. Biomed. Mater. Res. source
Not checked in the free run.
- Premisecitation
Histological analysis showed improved biocompatibility of NDGA-crosslinked scaffolds compared with GA-crosslinked scaffolds, with less inflammatory cell localization and infiltration.
“Histological analysis after the experiment revealed improved biocompatibility of the NDGA-crosslinked compared to the GA-cross-linked scaffolds as evidenced by less inflammatory cell localization and infiltration into the porous membranes.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [148] Ju Y. M., 2010, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
- Premisecitation
In long-term 10-week studies, polyurethane biodegradation was slower for polycarbonate polyurethanes than for polyether polyurethanes.
“In long-term studies (i.e., 10 weeks), biodegradation of PU was slower for polycarbonate PUs, containing a soft segment of polyhexamethylene carbonate, compared to polyether Pus that have a soft segment composed of polytetramethylene oxide.138”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [138] Mathur A. B., 1997, J. Biomed. Mater. Res. source
Not checked in the free run.
- Premisecitation
Small electrospun fibers (<6 μm in diameter) reduce the foreign body response more effectively than larger fibers (>6 μm).
“small fibers (<6 μm in diameter)151,163 reduce the FBR (i.e., capsule formation) more effectively than larger (>6 μm) fibers.”
Quote in the paperSubstantial claim0 of 2 sources checked - Premisecitation
Subcutaneous implantation of materials with 35 μm pores produced the thinnest and lowest density collagen capsules with high capillary presence.
“When implanted subcutaneously, materials with 35 μm pores were shown to yield the thinnest and lowest density collagen capsules with a high degree of capillaries in the tissue.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [157] Marshall A. J., 2004, ACS Polym. Prepr.
Not checked in the free run.
- Premisecitation
Increased vascularization correlated with the ability of inflammatory cells to infiltrate the porous membrane.
“this increased vascularization correlated with the ability of inflammatory cells to infiltrate the porous membrane.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [155] Brauker J. H., 1995, J. Biomed. Mater. Res. source
Not checked in the free run.
- Premisecitation
Significant inflammation and development of foreign body giant cells were reported for VEGF-producing biosensors.
“significant inflammation and the development of FBGCs were reported for VEGF-“producing” biosensors.204”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [204] Klueh U., 2005, Biomaterials source
Not checked in the free run.
- Premisecitation
Systemic use of dexamethasone can cause serious side-effects by depressing the innate immune response and increasing infection likelihood.
“systemic use of DX can cause serious side-effects by depressing the innate immune response, thus increasing the likelihood of infection.178–179”
Quote in the paperSubstantial claim0 of 2 sources checked - Premisecitation
Lower modulus fibers such as polyurethane showed reduced capsule formation compared to higher modulus materials such as polyethylene, polyester, and poly(L-lactic acid).
“lower modulus fibers (e.g., polyurethane) showing reduced capsule formation (i.e., size) compared to higher modulus materials (e.g., polyethylene, polyester and poly(L-lactic acid)).151”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [151] Sanders J. E., 2003, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
- Interpretationreasoning
The significance of VEGF/dexamethasone dual delivery for tissue reconstruction remains questionable because the studies contrast significantly in delivery methods, materials, and animal models.
“the above studies contrast significantly with respect to the delivery methods, materials, and animal models, and thus the significance of VEGF/DX dual delivery for tissue reconstruction remains questionable.”
Quote in the paperSubstantial claim - Premisecitation
Dexamethasone release reduced the inflammatory response by about 50% at 3 and 7 days compared to control PLGA/PVA hydrogel composites.
“The release of DX reduced the inflammatory response by ~50% at 3 and 7 d compared to control PLGA/PVA hydrogel composites.188”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [188] Patil S. D., 2004, Diabetes Technol. Ther. source
Not checked in the free run.
- Premisecitation
PLGA particles provided approximately zero-order dexamethasone release over one month after an initial burst of about 15%.
“While an initial burst release of ~15% of total DX was observed, the PLGA particles provided approximate zero-order kinetic release of DX over one month, indicating potential for long-term delivery.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [184] Hickey T., 2002, Biomaterials source
Not checked in the free run.
- Premisecitation
Clarke Error Grid Analysis indicated that only sensors 1 mm from VEGF-eluting pumps showed accuracy improvements versus controls.
“Clarke Error Grid Analysis indicated that only sensors 1 mm from the VEGF-eluting pumps showed accuracy improvements versus controls.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [203] Ward W. K., 2004, Diabetes Technol. Ther.
Not checked in the free run.
- Premisecitation
Norton et al. observed no real benefit in reducing the inflammatory response using dexamethasone-releasing PLGA microspheres after 2 or 6 weeks in rat subcutaneous tissue.
“Norton et al. observed no real benefit in reducing the inflammatory response using DX-releasing PLGA microspheres after 2 or 6 weeks in rat subcutaneous tissue.191”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [191] Norton L. W., 2007, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
- Premisecitation
The moduli of dermis and subcutaneous tissue range from 56-260 kPa and 0.12-23 kPa, respectively.
“the modulii of the dermis and subcutaneous tissue range from 56–260 kPa and 0.12–23 kPa, respectively,165–168”
Quote in the paperSubstantial claim0 of 4 sources checked- cites [165] Hendriks F. M., 2003, Skin Res. Technol. source
Not checked in the free run.
- cites [166] Van Houten E. E. W., 2003, J. Magn. Reson. Imaging source
Not checked in the free run.
- cites [167] Diridollou S., 2000, Int. J. Cosmetic Sci. source
Not checked in the free run.
- cites [168] Barel A., 1995
Not checked in the free run.
- Premisecitation
Glucocorticoids including dexamethasone have been shown to decrease the in vivo activity of VEGF.
“glucocorticoids including DX have been shown to decrease the in vivo activity of VEGF.207–209”
Quote in the paperSubstantial claim0 of 3 sources checked - Interpretationreasoning
Combining the two PLGA systems could provide constant dexamethasone delivery for more than one month.
“The combination of these two PLGA systems could provide constant DX delivery for more than one month.”
Quote in the paperSubstantial claim - Premisecitation
Biphasic decreases in IL-6 expression were observed at the lowest and highest moduli.
“biphasic decreases in IL-6 expression (i.e., a pro-inflammatory cytokine) were observed at the lowest and highest modulii.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [170] Irwin E. F., 2008, J. Biomater. Sci.-Polym E source
Not checked in the free run.
- Premisecitation
Moussy et al. reported that locally administered [3H]dexamethasone travelled an average of only 2.70 mm from the delivery point after 24 h.
“Moussy et al. reported that [3H]DX travelled only an average of 2.70 mm from the point of delivery after 24 h when administered locally.180”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [180] Moussy Y., 2006, Biotechnol. Prog. source
Not checked in the free run.
- Premisecitation
Ward and coworkers found decreased macrophage concentrations adjacent to implants 2 mm from an osmotic pump at 4 weeks, while tissue at least 17 mm away was not significantly different.
“Histological analysis revealed decreases in macrophage concentrations adjacent to implants 2 mm from the osmotic pump at 4 weeks, while tissue samples ≥17 mm away were not significantly different.181”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [181] Ward W. K., 2010, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
- Premisecitation
Mismatches in elastic modulus between a percutaneous implant and surrounding skin result in shear forces that induce a more severe foreign body response.
“mismatches in the elastic modulus between an implant and the skin that surrounds it will result in sheer forces that induce a more severe FBR.164”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [164] Holt B., 2008, J. Biomech. source
Not checked in the free run.
- Premisenone given
Physical and chemical alterations to CGM devices at the sensor-tissue interface have not drastically improved glucose sensor function to date.
“physical and chemical alterations to CGM devices at the sensor-tissue interface have not resulted in drastically improved glucose sensor function to date.”
Quote in the paperSubstantial claim - Premisenone given
Material modulus is an important factor for modulating the foreign body response to percutaneous biosensors on non-porous materials.
“a materials’ modulus is an important factor for modulating the FBR to percutaneous biosensors on non-porous materials as well.”
Quote in the paperSubstantial claim - Interpretationcitation
Dexamethasone must be delivered continuously for the duration of an implant to manifest anti-inflammatory benefits.
“This study clearly indicated that DX must be delivered continuously (i.e., for the duration of an implant) in order to manifest the anti-inflammatory benefits.”
Quote in the paperSubstantial claim - Premisecitation
The authors attributed the lack of significant glucose sensor performance improvements to VEGF-induced pro-inflammatory effects.
“The authors attributed the lack of significant glucose sensor performance improvements to VEGF-induced pro-inflammatory effects.203”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [203] Ward W. K., 2004, Diabetes Technol. Ther.
Not checked in the free run.
- Premisecitation
Local inflammation was 2-4 fold greater near VEGF-releasing materials relative to control substrates over the entire four-week study.
“Ultimately, local inflammation was 2–4 fold greater near the VEGF-releasing materials relative to control substrates over the entire four-week study.189”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [189] Patil S. D., 2007, J. Controlled Release source
Not checked in the free run.
- Premisecitation
A concern regarding VEGF use is increased local inflammation because cell migration and proliferation also correlate with angiogenesis.
“A concern regarding VEGF use is increased local inflammation because cell migration and proliferation also correlate with angiogenesis.200–201”
Quote in the paperNot a substantial claim0 of 2 sources checked - Premisecitation
Patil et al. found that capillary density was significantly increased at 3 and 4 weeks after implantation of VEGF-releasing PLGA/PVA hydrogel composites versus controls.
“Patil et al. implanted VEGF-releasing PLGA/PVA hydrogel composites into rat subcutaneous tissue and noted through histology that capillary density was significantly increased at 3 and 4 weeks after implantation versus controls (PVA hydrogels).189”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [189] Patil S. D., 2007, J. Controlled Release source
Not checked in the free run.
- Premisecitation
Irwin and coworkers observed reduced macrophage adhesion as the modulus of an interpenetrating polymer network decreased from 348 to 1.4 kPa.
“Irwin and coworkers observed a reduction in macrophage adhesion as the modulus of an interpenetrating polymer network was decreased from 348 to 1.4 kPa.170”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [170] Irwin E. F., 2008, J. Biomater. Sci.-Polym E source
Not checked in the free run.
- Interpretationnone given
Developing analytically accurate in vivo sensors that work for extended periods (at least weeks) remains a shortcoming and an insurmountable challenge because of the foreign body response.
“Unfortunately, the development of analytically accurate in vivo sensors that function for extended (i.e., at least weeks) periods remains a shortcoming and insurmountable challenge due to the FBR.”
Quote in the paperNot a substantial claim - Interpretationreasoning
Nitric oxide may be able to accomplish the hypothesized actions of dual dexamethasone/VEGF delivery while avoiding antagonistic behavior between the drugs.
“Nitric oxide may therefore be able to accomplish the hypothesized actions of dual DX/VEGF while avoiding the antagonistic behavior between the drugs.”
Quote in the paperSubstantial claim - Premisecitation
Nichols et al. studied how nitric oxide release duration (6 hours to 14 days) and payload (2.7 to 9.3 Vmol cm−2) affect the foreign body response, using 316L stainless steel wires as size-matched model sensors coated with various nitric oxide release formulations.
“Work by Nichols et al. examined the influence of NO-release duration and payload ranging from 6 h to 14 d and 2.7 to 9.3 Vmol cm−2, respectively, on the FBR using 316L stainless steel wires as model sensors (with respect to size) coated with different NO release formulations.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [240] Nichols S. P., 2012, Biomaterials source
Not checked in the free run.
- Interpretationcitation
Given nitric oxide's roles in the immune response, favorable tissue reactions to nitric oxide-releasing substrates would be expected in vivo.
“Given NO’s roles in the immune response, favorable tissue reactions to NO-releasing substrates would be expected in vivo.217”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [217] Carpenter A. W., 2012, Chem. Soc. Rev. source
Not checked in the free run.
- Premisecitation
Nitric oxide-releasing microdialysis probes after 7 days recovered larger glucose concentrations compared to controls, indicating lower resistance to mass transfer in the surrounding tissue.
“The NO-releasing probes after 7 d were reported to recover larger glucose concentrations compared to controls (Figure 4), indicating lower resistance to mass transfer in the surrounding tissue.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [239] Nichols S. P., 2011, Anal. Chem. source
Not checked in the free run.
- Premisecitation
The authors concluded that the mitigated foreign body response by nitric oxide release was at least partially responsible for the superior glucose recovery.
“The authors concluded that the mitigated FBR by NO release was thus at least partially responsible for the superior glucose recovery.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [239] Nichols S. P., 2011, Anal. Chem. source
Not checked in the free run.
- Premisecitation
Nitric oxide is believed to control inflammatory cell recruitment in the early stages of the foreign body response.
“NO is also believed to control inflammatory cell recruitment in the early stages of the FBR.215”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [215] Schwentker A., 2002, Nitric Oxide-Biol. Chem. source
Not checked in the free run.
- Interpretationcitation
This work suggests that nitric oxide release may represent an important strategy for improving in vivo glucose sensor performance.
“This work suggests that NO release may represent an important strategy for improving in vivo glucose sensor performance.”
Quote in the paperSubstantial claim - Premisecitation
In Nichols et al.'s study, inflammation was only influenced by substrates that were still actively releasing nitric oxide at the time of explantation, unlike capsule thickness.
“In contrast to the capsule thickness, inflammation was only affected by substrates still actively releasing NO at time of explants.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [240] Nichols S. P., 2012, Biomaterials source
Not checked in the free run.
- Interpretationcitation
The angiogenic behavior of nitric oxide may help avoid the avascular encapsulation that plagues glucose sensor performance.
“The angiogenic behavior exhibited by NO may thus prove helpful for avoiding the avascular encapsulation that plagues glucose sensor performance.”
Quote in the paperSubstantial claim - Interpretationcitation
Based on studies to date, the anti-inflammatory effect of localized (surface) nitric oxide release lasts only while the release is occurring.
“Based on studies to date, the anti-inflammatory influence by localized (i.e., surface) NO release persist only during the release event.”
Quote in the paperSubstantial claim - Premisecitation
Nitric oxide release influences the foreign body response.
“While these studies highlight the effect of NO release on the FBR”
Quote in the paperSubstantial claim - Premisecitation
Gifford et al. found that the analytical performance of percutaneous nitric oxide-releasing sensors in rats improved by 2.4% and 2.1% (Clarke Error Grid Analysis) relative to controls on days 1 and 3, respectively.
“the analytical performance of percutaneous NO-releasing sensors in rats was improved by 2.4 and 2.1% (Clarke Error Grid Analysis) for the NO-releasing sensors relative to controls on days 1 and 3, respectively.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [103] Gifford R., 2005, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
- Interpretationcitation
The short-term benefits reported by Gifford et al. might be further improved by a larger and more sustained nitric oxide release profile.
“These results indicate that the short-term benefits reported by Gifford et al. may be further enhanced with a greater and more sustained NO release profile.”
Quote in the paperSubstantial claim0 of 2 sources checked - Premisereasoning
Nitric oxide influences the foreign body response in ways that may affect in vivo glucose sensor performance.
“NO influences the FBR in ways that may affect in vivo glucose sensor performance.”
Quote in the paperSubstantial claim - Interpretationnone given
Recent insights into specific in vivo impediments to sensor function have helped create strategies to reduce inflammation and improve tissue integration of sensor materials.
“Recent insights regarding specific in vivo impediments to sensor function have helped form strategies to reduce inflammation and improve tissue integration of sensor materials”
Quote in the paperSubstantial claim- Rests on an assumption: The outer sensor membrane protects the enzyme.
- Rests on an assumption: The outer sensor membrane tunes the sensor response.
- Rests on an assumption: The outer sensor membrane determines the magnitude of the foreign body response.
- Premisereasoning
Nitric oxide release has the potential to enhance glucose sensor performance.
“and its potential to improve glucose sensor performance”
Quote in the paperSubstantial claim
- May combine two claims. 93
- Classified as probably not a substantial claim. 15
- The quote only partly states this claim. 1
May combine two claims.
Premisenone givenContinuous iontophoretic current causes skin erythema and irritation.
“However, the continuous applied current causes skin erythema and irritation.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationPhotobleaching of fluorophores and tissue scattering are significant drawbacks of optical glucose detection.
“Photobleaching of the fluorophore and scattering in tissue are significant drawbacks.19,35–36”
Quote in the paperNot a substantial claim0 of 3 sources checkedMay combine two claims.
Premisenone givenFully subcutaneous enzyme-immobilized amperometric biosensors can be implanted for months to years, whereas percutaneous versions are used for less than one month.
“Enzyme-immobilized amperometric biosensors have been implanted fully subcutaneously as CGM devices for extended periods (months to years) or percutaneously for <1 month.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationMost electron mediators used in second-generation glucose biosensors are toxic, and mediator-oxygen competition persists.
“Unfortunately, most mediators are toxic and competition between the mediator and oxygen still exists.19,22”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [19] Vaddiraju S., 2010, J. Diabetes Sci. Technol. source
Not checked in the free run.
- cites [22]
Not checked in the free run.
May combine two claims.
PremisecitationMicrodialysis avoids direct sensor implantation, but in vivo glucose recovery is erratic because of the foreign body response.
“Microdialysis avoids direct implantation of a sensor but the glucose measurement (i.e., recovery) remains erratic in vivo due to the foreign body response.19,24–25”
Quote in the paperNot a substantial claim0 of 3 sources checkedMay combine two claims.
PremisecitationSweating, often linked to hypoglycemia, alters glucose extraction rate and causes erroneous iontophoretic readings.
“Additionally, sweating, often associated with hypoglycemia, affects the rate of extraction of glucose and therefore causes erroneous results when readings must be most accurate.29–30”
Quote in the paperNot a substantial claim0 of 2 sources checkedMay combine two claims.
InterpretationreasoningEnzyme-based electrochemical glucose biosensors have high selectivity and sensitivity, but their dynamic range is limited by oxygen availability.
“Although enzyme-based electrochemical glucose biosensors are characterized with high selectivity and sensitivity due their enzymatic nature, the dynamic range of such sensors is limited by co-substrate (i.e., oxygen) availability.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationAlmost all invasive sensing devices have infection risks, discomfort, and analytical response problems related to the foreign body response.
“Almost all invasive sensing devices are characterized by infection risks, discomfort, and analytical response issues related to the foreign body response (FBR).29–30”
Quote in the paperSubstantial claim0 of 2 sources checkedMay combine two claims.
PremisecitationMiniaturization of optical glucose monitoring instrumentation is not currently possible, preventing personalized continuous monitoring devices.
“Moreover, miniaturization of the instrumentation is not currently possible thus precluding personalized devices for continuous monitoring.19”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [19] Vaddiraju S., 2010, J. Diabetes Sci. Technol. source
Not checked in the free run.
May combine two claims.
PremisereasoningIontophoretic glucose sensors are non-invasive and less prone to fouling because skin filters large biomolecules.
“Iontophoretic electrochemical sensors are not invasive and experience less fouling because of the skin’s ability to filter large biomolecules.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisereasoningPercutaneous needle-type microsensors have a shorter stabilization period than subcutaneous sensors but carry infection risk from penetrating the dermis.
“Though such sensors typically are characterized as having a shorter stabilization period (e.g., 2–4 h) compared to subcutaneous glucose sensors, the device penetrates through an opening in the dermis with concomitant infection risk.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationRaman spectroscopy gives narrow and distinct peaks but requires long spectral acquisition and stabilization times.
“While Raman spectroscopy gives narrow and distinct peaks (in contrast to NIR absorbance), long spectral acquisition and stabilization times are required.30”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [30] Vashist S. K., 2012, Anal. Chim. Acta source
Not checked in the free run.
May combine two claims.
PremisecitationOptical glucose detection is sensitive and does not damage the host, but skin pigmentation and epidermal thickness can worsen analytical response.
“While optical detection provides sensitive detection without damaging the host, skin pigmentation and epidermal thickness can negatively impact the analytical response among hosts.35–36”
Quote in the paperNot a substantial claim0 of 2 sources checkedMay combine two claims.
PremisecitationThe electrode potential used to monitor hydrogen peroxide also oxidizes endogenous electroactive species and produces high current densities.
“Additionally, the working electrode potential required to monitor hydrogen peroxide (i.e., ~+0.6 V vs. Ag/AgCl) will also oxidize electroactive endogenous species (e.g., ascorbic acid and acetaminophen) and create high current densities.19”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [19] Vaddiraju S., 2010, J. Diabetes Sci. Technol. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationElectrode fouling, or passivation, occurs when diffusible small molecules contact the electrode surface after penetrating the sensor membrane.
“Electrode fouling (often called electrode passivation) is another cause of sensor instability, and occurs when diffusible small molecules come into contact with the surface of the electrode after penetration of the sensor membrane.74”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [74] Wisniewski N., 2000, Colloid. Surface. B source
Not checked in the free run.
May combine two claims.
PremisecitationLong-term implanted glucose sensors in humans provided accurate readings while immobile, but posture changes led to erratic outputs.
“For example, Gilligan et al. found that long-term implanted glucose sensors in humans provided accurate sensor readings while immobile, but posture changes (i.e., standing and/or moving) led to erratic outputs.85”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [85] Gilligan B. C., 2004, Diabetes Technol. Ther. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenCommercial CGM sensors are not intended as warning or prognostic devices but as tools to inform users and physicians about glucose trends.
“However, these sensors are not intended as warning or prognostic devices but rather as tools to inform users and physicians of trends in glucose fluctuations.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationCurrent numerical and clinical accuracy criteria for CGM include linear regressions and correlation coefficients, MAD and MARD, Clarke Error Grid Analysis, and ISO criteria.
“Current numerical and clinical accuracy criteria for CGM includes linear regressions and correlation coefficients; mean (or median) absolute and relative absolute difference (MAD and MARD); Clarke Error Grid Analysis (Clarke EGA); and, International Standard Organization (ISO) criteria.76”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [76] Clarke W. L., 2007, J. Diabetes Sci. Technol. source
Not checked in the free run.
May combine two claims.
Premisenone givenChanges in blood dielectric properties are not specific to glucose, leading to poor accuracy in impedance-based glucose measurements.
“Unfortunately, the changes in blood dielectric properties are not specific to glucose, resulting in poor accuracy.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationSubcutaneous oxygen tension in humans ranges from about 40 mm Hg to 130 mm Hg and is affected by anesthetics and hypoxia at the implantation site.
“Subcutaneous oxygen tension for humans ranges from 40 mm Hg (~5 kPa) to 130 mm Hg (~17kPa) with partial pressures affected by anesthetics and hypoxia at the implantation site.70”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [70] Koschwanez H. E., 2007, Biomaterials source
Not checked in the free run.
May combine two claims.
PremisecitationPressures as low as 2 kPa diminish blood flow near the skin, and 7 kPa completely occluded blood circulation in diabetic patients, whereas non-diabetics withstood up to 22 kPa before total blood occlusion.
“Pressures as low as 2 kPa have been shown to diminish blood flow near the skin while only 7 kPa completely occluded blood circulation in diabetic patients whereas non-diabetics withstood pressures up to 22 kPa before total blood occlusion.88”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [88] Petrofsky J. S., 2011, J. Diabetes Sci. Technol. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationThe continuous glucose-error grid comprises a point-error grid analysis for blood glucose measurement accuracy and a rate-error grid analysis for prediction capability.
“Because CGM systems also provide information on glucose fluctuations, the continuous glucose-error grid (CG-EGA) has been introduced comprising of (1) a point-error grid analysis (P-EGA) that evaluates the sensor accuracy in terms of accurate blood glucose measurements; and, (2) a rate-error grid analysis (R-EGA) that assesses the prediction capability of the sensor.77”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [77] Kovatchev B. P., 2004, Diabetes Care source
Not checked in the free run.
May combine two claims.
Premisenone givenOxygen concentration in interstitial fluid is about ten times lower than glucose concentration, creating an oxygen deficit that is addressed by an outer diffusion-controlled membrane.
“Oxygen concentration in interstitial fluid is approximately ten times lower than the concentration of glucose in interstitial fluid resulting in an “oxygen deficit” state that is addressed by an outer diffusion-controlled membrane.”
Quote in the paperSubstantial claimMay combine two claims.
Interpretationnone givenThe analytical performance of CGM sensors changes drastically upon implantation, making methods for defining and assessing accuracy critical for clinical use.
“Since the analytical performance of CGM sensors changes drastically upon implantation, methods for defining and assessing sensor accuracy are critical for clinical use.”
Quote in the paperSubstantial claimMay combine two claims.
InterpretationreasoningEven with accurate calibration, repeated calibration is required because sensor sensitivity changes over time due to physiological fluctuations and the foreign body response.
“Even with an accurate calibration, repeated calibration is required as the sensor sensitivity changes over time due to physiological fluctuations and the foreign body response to the sensor.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationSince 1999, CGM systems have been FDA approved, but only percutaneously implanted electrochemical glucose sensors are currently sold in the United States.
“Since 1999, CGM systems have been approved by the FDA but only percutaneously implanted electrochemical glucose sensors are currently for sale in the United States.53”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [53] Henning T., 2010
Not checked in the free run.
May combine two claims.
Premisenone givenElectrochemical detection of hydrogen peroxide requires oxygen, which is a cofactor in the glucose oxidase reaction.
“The electrochemical detection of hydrogen peroxide requires oxygen, a cofactor in the GOx enzymatic reaction.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationSurface enhanced Raman spectroscopy dramatically shortens acquisition times and improves sensitivity and limit of detection.
“Recent advances have demonstrated that surface enhanced Raman spectroscopy (SERS) dramatically decreases acquisition times with concomitant improvements in both sensitivity and limit of detection.45–46”
Quote in the paperNot a substantial claim0 of 2 sources checkedMay combine two claims.
PremisereasoningFDA-regulated sensor lifetimes of 5-7 days require regular biosensor replacement, creating significant financial burden for patients.
“Due to finite FDA-regulated sensor lifetimes (5–7 d), the biosensor must be replaced on a regular basis with significant financial burden on the individual patient.”
Quote in the paperNot a substantial claimMay combine two claims.
Interpretationnone givenEmpirical data suggest in vivo lag times of 10-15 min, indicating that angiogenesis has an integral function in early granulation tissue.
“empirical data suggests that lag times range from 10–15 min in vivo, indicating the integral function of angiogenesis in early granulation tissue.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationcitationThe reversibility seen after rinsing indicated that the process was passive and probably resulted from biofouling on the sensor.
“Nevertheless, this reversibility indicated that the process was passive and likely caused by biofouling on the sensor.100”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [100] Thomé-Duret V., 1996, Diabetes Metab.
Not checked in the free run.
May combine two claims.
PremisecitationSensor lag time for native tissue was estimated at about 20 min, but tripled when modeled with reduced diffusion due to a capsule.
“Sensor lag times for native tissue was estimated at ~20 min, but tripled when modeled with decreased diffusion due to a capsule.107”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [107] Sharkawy A. A., 1997, J. Biomed. Mater. Res. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationMacrophages serve three primary functions: host defense, wound healing, and immune regulation.
“Indeed, macrophages serve three primary functions in the body: host defense, wound healing, and immune regulation.95”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [95] Mosser D. M., 2008, Nat. Rev. Immunol. source
Not checked in the free run.
May combine two claims.
PremisecitationInjecting 10^4-10^5 mast cells at the implant site caused sensor performance to recover within about 15 min, followed by a decrease in glucose response after 1-2 days.
“While glucose sensor performance recovered soon after injection (~15 min), the sensor response to glucose decreased after 1–2 days”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [106] Klueh U., 2010, Biomaterials source
Not checked in the free run.
May combine two claims.
PremisecitationThe foreign body response can cause local pH to drop as low as 3.6, disrupting biosensor performance because glucose oxidase activity is pH dependent.
“This process can result in a local pH’s dropping as low as 3.6 and disrupting biosensor performance as the activity of GOx is pH dependent.94”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [94] Zhao Q. H., 1993, J. Biomed. Mater. Res. source
Not checked in the free run.
May combine two claims.
PremisecitationIn vivo glucose sensitivity peaked at day 7 and then decreased for the remainder of the study.
“The glucose sensitivity in vivo peaked at day 7, but then decreased for the duration of the study.108”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [108] Dungel P., 2008, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
May combine two claims.
PremisecitationIn mast cell-deficient mice, sensor performance was markedly better and remained reliable throughout the 28-day period.
“Sensor performance in mast cell-deficient mice was markedly better with reliable sensor function throughout the 28-day period.106”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [106] Klueh U., 2010, Biomaterials source
Not checked in the free run.
May combine two claims.
InterpretationcitationMicrodialysis probes consume much more glucose than electrochemical glucose sensors and may therefore underestimate biofouling effects in vivo.
“microdialysis probes consume significantly more glucose than electrochemical glucose sensors and therefore may underestimate the effects of biofouling in vivo.105”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [105] Lowry J. P., 1998, J. Neurochem. source
Not checked in the free run.
May combine two claims.
PremisecitationIn the same study, rinsing improved the glucose response but did not restore it to pre-implantation levels.
“response to glucose improved after rinsing, albeit not to pre-implantation levels.100”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [100] Thomé-Duret V., 1996, Diabetes Metab.
Not checked in the free run.
May combine two claims.
InterpretationreasoningCollagen encapsulation persists for the lifetime of the device and negatively impacts sensor performance with respect to sensitivity and response, such as lag times.
“The collagen encapsulation will persist for the lifetime of the device, negatively impacting sensor performance with respect to sensitivity and response (e.g., lag times).”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationTecoflex SG-85A polyurethane membranes on needle-type glucose sensors in rats after 30 h provided the biocompatibility often seen with polyurethane and ensured ideal sensor performance by limiting glucose diffusion.
“The Tecoflex SG-85A membrane provided the biocompatibility often observed with polyurethane while also ensuring ideal sensor performance by limiting glucose diffusion.34”
Quote in the paperSubstantial claim0 of 2 sources checkedMay combine two claims.
PremisecitationThe physical properties of an implant, such as its size, affect the FBR, and the large size of the stainless steel cage will influence the overall immune response to the materials.
“the physical properties of the implant (e.g., size) impact the FBR, and the large size of the stainless steel cage will influence the overall immune response to the materials.115”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [115] Ward W. K., 2002, Biomaterials source
Not checked in the free run.
May combine two claims.
PremisecitationAt 20 months, capsules were thinner at the implant's corners, while the face closest to the skin had a thicker capsule than the opposite side.
“At 20 months, thinner capsules were observed at the implant’s corners while the face of the implant closest to the skin had a thicker capsule than the opposite side.130”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [130] Li D. J., 1999, J. Biomed. Mater. Res. source
Not checked in the free run.
May combine two claims.
PremisecitationHistological analysis revealed delayed neovascularization and less matrix production in diabetic rabbits.
“Histological analysis revealed delayed neovascularization and less matrix production in the diabetic rabbits”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [128] Gerritsen H., 2000, J. Biomed. Mater. Res. source
Not checked in the free run.
May combine two claims.
PremisecitationSubcutaneous implants had no blood vessels or collagen inside the porous material, while percutaneous experiments showed significant collagen and vascularization, indicating a differential FBR depending on whether the implant was purely subcutaneous or percutaneous.
“While examination of the subcutaneous implant noted no blood vessels or collagen within the interior of the porous material, the percutaneous experiments revealed significant levels of collagen and vascularization, indicating a differential FBR dependent on the nature (i.e., purely subcutaneous vs. percutaneous) of the implant.121”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [121] Koschwanez H. E., 2008, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
May combine two claims.
PremisecitationHuman subcutaneous tissue had a high concentration of adipose cells, whereas rat tissue had larger amounts of collagen.
“Histology samplings from human subcutaneous tissue showed a high concentration of adipose cells while rat tissue was characterized with larger amounts of collagen.126”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [126] Wisniewski N., 2002, Am. J. Physiol.-Endocrinol. Metab source
Not checked in the free run.
May combine two claims.
InterpretationcitationThe increases in mass transfer in those simulations were not attributed to any specific part of the FBR and could arise from collagen capsule thickness, blood vessel density, or other unanticipated factors.
“the increases to mass transfer were not attributed to any specific part of the FBR and could originate from collagen capsule thickness, blood vessel density, or other unanticipated factors.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [110] Jablecki M., 2000, Anal. Chem. source
Not checked in the free run.
May combine two claims.
PremisecitationThe optical tissue window enables tissue monitoring and correlation with sensor performance.
“The optical tissue window enables tissue monitoring and correlation to the sensor performance.116–118”
Quote in the paperNot a substantial claim0 of 3 sources checkedMay combine two claims.
PremisecitationNafion-coated CGM probes implanted in canines were functional for up to 10 days, but the membranes were unstable, with significant cracking and eventual failure.
“Moussy et al. implanted Nafion-coated CGM probes into canines that proved functional for up 10 days, but ultimately the membranes were deemed unstable with significant cracking and eventual failure.122”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [122] Moussy F., 1994, Int. J. Artif. Organs source
Not checked in the free run.
Classified as probably not a substantial claim.
InterpretationcitationThese results require caution when extrapolating results from animal models to humans.
“Taken together, these results necessitate careful consideration and caution when extrapolating results from animal models to humans.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [126] Wisniewski N., 2002, Am. J. Physiol.-Endocrinol. Metab source
Not checked in the free run.
May combine two claims.
PremisecitationTextured surfaces elicited a more favorable FBR, and much of the response was attributed to differential shear stress from interaction between the textured surface and surrounding fatty tissue.
“While textured surfaces elicited a more favorable FBR, much of the response that did occur was attributed to differential sheer stress caused by the interaction between the textured surface of the device and the surrounding fatty tissue.132”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [132] Picha G. J., 1996, J. Biomed. Mater. Res. source
Not checked in the free run.
May combine two claims.
PremisecitationAnesthesia is not required to observe tissue in real time, which matters because anesthesia can alter microvasculature circulation.
“Anesthesia is not required to observe the tissue in real-time, an important consideration for glucose sensor performance correlation as anesthesia can alter microvasculature circulation.116”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [116] Makale M. T., 2005, Am. J. Physiol.-Heart C source
Not checked in the free run.
May combine two claims.
InterpretationcitationTemporary signal reductions may result from local tissue damage caused by forces exerted on the sensor and may be solved by using more flexible materials.
“Therefore, temporary signal reductions may actually be the result of local tissue damage caused by forces exerted on the sensor and may be solved by using more flexible materials.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [133] Klueh U., 2011, J. Diabetes Sci. Technol. source
Not checked in the free run.
Classified as probably not a substantial claim.
InterpretationcitationThese model results identify the histological parameters of key interest when assessing the biocompatibility of materials for glucose sensors.
“the results do identify the histological parameters of key interest when assessing the biocompatibility of materials for glucose sensors.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [111] Novak M. T., 2010, Anal. Bioanal. Chem. source
Not checked in the free run.
May combine two claims.
PremisecitationThe Novak model concluded that collagen capsule thickness was the primary source of sensor lag time and had little impact on sensor response attenuation.
“The model was ultimately used to conclude that collagen capsule thickness, a common histological parameter, was the primary source of sensor lag time with little impact on sensor response attenuation.111”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [111] Novak M. T., 2010, Anal. Bioanal. Chem. source
Not checked in the free run.
May combine two claims.
PremisecitationWhen the same materials were implanted percutaneously, histological differences were less apparent, with porous coatings giving a twofold increase in vascularization and a twofold increase in collagen content compared with bare sensors at 2 weeks.
“when the same materials were implanted percutaneously, histological differences were less apparent, with porous coatings giving a twofold increase in vascularization and a twofold increase, rather than decrease, in collagen content compared to bare sensors at 2 weeks.121”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [121] Koschwanez H. E., 2008, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationJablecki and Gough's simulations concluded that increased mass transfer would increase lag and could potentially reduce the magnitude and differences when glucose sensor signals fluctuate between high and low.
“Simulations of glucose concentration oscillations by Jablecki and Gough concluded that increases in mass transfer would increase lag and could potentially decrease the magnitude and differences when fluctuating between high and low glucose sensor signals.110”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [110] Jablecki M., 2000, Anal. Chem. source
Not checked in the free run.
May combine two claims.
PremisecitationPolyurethane allows sufficient oxygen transport while limiting glucose diffusion to the sensor.
“PU allows for sufficient oxygen transport while limiting glucose diffusion to the sensor.136”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [136] Zhang Y., 1993, Anal. Chim. Acta source
Not checked in the free run.
May combine two claims.
PremisecitationCollagen encapsulation around PU-S-PEO substrates was about 45% thinner than around PU substrates, although capillary density did not differ.
“The collagen encapsulation surrounding the PU-S-PEO substrates was ~45% thinner than those around the PU substrates though no differences in capillary density were observed.115”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [115] Ward W. K., 2002, Biomaterials source
Not checked in the free run.
May combine two claims.
PremisecitationPLLA foams on non-functioning sensors implanted subcutaneously showed decreased collagen capsule thickness and increased capillary density compared with bare non-functional sensors.
“When coated onto non-functioning sensors and implanted subcutaneously, the PLLA foams exhibited the expected decrease in collagen capsule thickness and increased capillary density compared to bare non-functional sensors.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [121] Koschwanez H. E., 2008, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
May combine two claims.
PremisecitationIn vitro examination of silicone-modified polyurethane significantly inhibited adhesion and FBGC formation, possibly explaining the in vivo benefits observed.
“In vitro examination of silicone-modified PU was also found to significantly inhibit adhesion and FBGC formation, possibly explaining the in vivo benefits observed.140”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [140] Jones J. A., 2004, J. Biomater. Sci., Polym. Ed. source
Not checked in the free run.
May combine two claims.
PremisecitationAfter subcutaneous implantation in humans, one of five biosensors functioned for about 6 months, with at least 90% of measured glucose concentrations in the A and B regions of the Clarke Error Grid.
“Following subcutaneous implantation into humans, one of five biosensors functioned for ~6 months with ≥90% of all measured glucose concentrations falling within the A and B regions of the resulting Clarke Error Grid (i.e., clinically accurate and acceptable, respectively).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [85] Gilligan B. C., 2004, Diabetes Technol. Ther. source
Not checked in the free run.
May combine two claims. The quote only partly states this claim.
PremisecitationEpoxy-polyurethane membranes allowed fabrication of functional glucose sensors in rats for up to 56 days with good sensitivity.
“The authors reported that this membrane allowed for the fabrication of functional glucose sensors in rats for up to 56 days with good sensitivity.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [141] Yu B., 2006, Biosens. Bioelectron. source
Not checked in the free run.
May combine two claims.
PremisecitationPoly(2-hydroxyethylmethacrylate-co-methacrylic acid) implants with 30-40 μm pores increased vascularization and reduced capsule thickness in rat myocardium over 4 weeks.
“poly(2-hydroxyethylmethacrylate-co-methacrylic acid) implants with 30–40 μm pores were reported to increase vascularization and reduce capsule thickness when placed into the myocardium of rats over a 4-week period.160”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [160] Madden L. R., 2010, Proc. Natl. Acad. Sci. U.S.A. source
Not checked in the free run.
May combine two claims.
Study design and conductcitationThe accuracy of hydrogel-coated biosensors was not examined, so the impact of the hydrogel coating on accuracy remains unclear.
“Even with these benefits, the accuracy was not examined and it is unclear what impact the hydrogel coating would provide in this respect.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [147] Yu B. Z., 2008, Biosens. Bioelectron. source
Not checked in the free run.
May combine two claims.
PremisecitationTissue around porous PVA materials exhibited increased vascularization and decreased collagen capsule thickness.
“the tissue around the porous materials exhibited increased vascularization and decreased collagen capsule thickness.107”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [107] Sharkawy A. A., 1997, J. Biomed. Mater. Res. source
Not checked in the free run.
May combine two claims.
PremisecitationVascular density adjacent to porous PVA samples was increased relative to controls, with 60 μm pores showing the greatest vascular density.
“The observed vascular density adjacent to the porous PVA samples was increased relative to controls, with the 60 μm pores exhibiting the greatest vascular density”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [153] Sharkawy A. A., 1998, J. Biomed. Mater. Res. source
Not checked in the free run.
May combine two claims.
PremisecitationSensors lacking the ePTFE membrane were functional for approximately 94 days, with a best-case recalibration interval of 18 days.
“sensors lacking the ePTFE membrane (i.e., having only an underlying layer of unspecified composition) were functional for approximately 94 d with a best-case recalibration interval of 18 d.156”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [156] Updike S. J., 2000, Diabetes Care source
Not checked in the free run.
May combine two claims.
PremisecitationHydrogel-coated biosensors were still functional after 21 days, whereas only 13.5% of controls were still functional.
“Hydrogel-coated biosensors were still functional after 21 days whereas only 13.5% of the controls were still functional.147”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [147] Yu B. Z., 2008, Biosens. Bioelectron. source
Not checked in the free run.
May combine two claims.
PremisecitationOnly one of nine sensors functioned for 56 days, and seven of nine lost functionality within 17 days or less.
“However, only one of the nine sensors functioned this long. Indeed, seven of the nine sensors lost functionality in 17 d or less.141”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [141] Yu B., 2006, Biosens. Bioelectron. source
Not checked in the free run.
May combine two claims.
InterpretationreasoningChemical modifications may improve tissue biocompatibility, but they have not led to major improvements in sensor performance in vivo.
“These results suggest that chemical modifications may improve tissue biocompatibility, but ultimately they have not led to major improvements on sensor performance in vivo.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationPorous materials showed a statistically significant increase in total macrophage biomarkers but a significant reduction in pro-inflammatory macrophage biomarkers.
“porous materials demonstrated a statistically significant increase in total macrophage biomarkers, yet a significant reduction (P < 0.05) in macrophage biomarkers associated with the pro-inflammatory macrophage phenotype.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationControl sensor membranes at 28 days had a fibrous capsule of about 500 μm, while capsules around hydrogel-based sensors were roughly 30-60 μm.
“Control sensor membranes (epoxy-polyurethane) at 28 days were characterized with a fibrous capsule of ~500 Vm while the capsules around hydrogel-based sensors were roughly 30–60 Vm.15”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [15] Wang C., 2008, Biomacromolecules source
Not checked in the free run.
May combine two claims.
PremisecitationBiosensors with an ePTFE membrane having 1-10 μm pores implanted in non-diabetic canines were operable for more than 160 days, with a best-case recalibration interval of 20 days.
“Updike and coworkers implanted biosensors with an affixed expanded PTFE (ePTFE) membrane having 1–10 μm pores in non-diabetic canines and found they were operable for greater than 160 d with a best-case recalibration interval of 20 d.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [156] Updike S. J., 2000, Diabetes Care source
Not checked in the free run.
May combine two claims.
PremisecitationTissue surrounding materials with larger or smaller pores was avascular and had thicker, denser collagen capsules.
“Conversely, tissue surrounding materials with either larger or smaller pores were avascular with thicker, denser collagen capsules.157”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [157] Marshall A. J., 2004, ACS Polym. Prepr.
Not checked in the free run.
May combine two claims.
PremisecitationPellethane control substrates showed significant inflammatory cell adherence and collagen encapsulation, whereas PEG-modified hydrogels had fewer cells, indicating improved biocompatibility.
“While Pellethane (i.e., polyurethane) control substrates exhibited significant inflammatory cell adherence and collagen encapsulation, PEG-modified hydrogels were characterized by less cells indicating improved biocompatibility.144”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [144] Quinn C. A. P., 1997, Biomaterials source
Not checked in the free run.
May combine two claims.
PremisecitationNorton et al. observed the expected increase in vascularization due to VEGF but no decrease in local inflammation from dexamethasone release.
“Norton et al. carefully examined the tissue response to VEGF-, DX-, and VEGF/DX-releasing hydrogels in a rat subcutaneous model,191 observing the expected increase in vascularization due to VEGF but no decrease in local inflammation from DX release.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [191] Norton L. W., 2007, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
May combine two claims.
InterpretationreasoningOverall, the reviewed studies suggest that decreased inflammation likely enhances long-term glucose biosensor functionality, though achieving long-term dexamethasone release while avoiding systemic effects remains challenging.
“Overall, these studies suggest that decreased inflammation likely enhances long-term glucose biosensor functionality, though the challenges of achieving long-term DX release while avoiding systemic effects remains.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationInitial experiments with simultaneous delivery of VEGF and dexamethasone from PLGA particles showed enhanced tissue integration, decreased inflammation, and increased vascularization in a rat model.
“initial experiments examining the simultaneous delivery of VEGF and DX from PLGA particles showed enhanced tissue integration, decreased inflammation, and increased vascularization in a rat model.189”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [189] Patil S. D., 2007, J. Controlled Release source
Not checked in the free run.
May combine two claims.
PremisecitationDexamethasone-releasing glucose biosensors retained more than 50% of their original sensitivity 2 weeks after implantation, while control membranes dropped to 15-42% of original levels.
“DX-releasing glucose biosensors retained >50% of their original sensitivity 2 weeks after implantation, the sensitivity of control membranes dropped to 15–42% of their original levels.187”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [187] Ju Y. M., 2010, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
May combine two claims.
PremisecitationCombined dexamethasone and VEGF release produced a 50% reduction in inflammation after the first week, similar to dexamethasone alone, though inflammation at weeks 2-4 was still greater than with dexamethasone alone.
“Histology surrounding PLGA particle-containing hydrogels with combined DX and VEGF release revealed a 50% reduction in inflammation after the first week, similar to that of DX release alone, though inflammation at weeks 2–4 was still greater than DX alone.189”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [189] Patil S. D., 2007, J. Controlled Release source
Not checked in the free run.
May combine two claims.
InterpretationreasoningModulus-matching strategies may help reduce chronic inflammation from motion-damaged tissue, though more empirical evidence is needed.
“Although more empirical evidence is needed, this strategy may prove helpful in reducing chronic inflammation from motion-damaged tissue.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationDexamethasone-releasing composites still exhibited reduced inflammation and fibrosis compared to control hydrogels at about 3 weeks, demonstrating that local dexamethasone release can arrest fibrous encapsulation.
“As chronic inflammation set in at ~3 weeks, the DX-releasing composites still exhibited reduced inflammation and fibrosis compared to control hydrogels, demonstrating the ability of local DX release to arrest fibrous encapsulation.188”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [188] Patil S. D., 2004, Diabetes Technol. Ther. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationVEGF is a cytokine released by macrophages and keratinocytes during wound reconstruction to promote angiogenesis.
“Vascular endothelial growth factor, or VEGF, is a cytokine released by macrophages and keratinocytes during wound reconstruction to promote angiogenesis.195–197”
Quote in the paperNot a substantial claim0 of 3 sources checkedProbably not a substantial claim: may not pass S1 (asserted).
PremisereasoningLocal delivery of dexamethasone from glucose biosensors was hypothesized to circumvent undesirable systemic side effects.
“Local delivery of DX from glucose biosensors was hypothesized to circumvent undesirable systemic side effects of DX.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationThe functional lifetime of glucose sensors near a VEGF-releasing pump was 63 days, whereas control saline sensors stopped working accurately at 34 days.
“The functional lifetime of the sensors near the pump was 63 days whereas control (saline) sensors stopped working accurately at 34 days.203”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [203] Ward W. K., 2004, Diabetes Technol. Ther.
Not checked in the free run.
May combine two claims.
PremisecitationShort dexamethasone delivery diminished acute inflammation at 3 and 8 days but inflammation significantly increased at 30 days, indicating that dexamethasone release delayed the immune response.
“The acute inflammatory response was diminished at 3 and 8 d, but inflammation was significantly increased at 30 d compared to the shorter time points (i.e., 3 and 8 d), indicating that DX release simply delayed the immune response.186”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [186] Bhardwaj U., 2007, J. Diabetes Sci. Technol. source
Not checked in the free run.
May combine two claims.
PremisecitationHigh dexamethasone concentrations over 28 days (0.17 mg/kg) led to a systemic reduction in cortisol levels, while low concentrations (<0.10 mg/kg) did not.
“high concentrations of DX over 28 d (i.e., 0.17 mg/kg) led to a systemic reduction in cortisol levels while low concentrations (i.e., <0.10 mg/kg) did not cause such effects.181”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [181] Ward W. K., 2010, J. Biomed. Mater. Res. Part A source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationNitric oxide is an endogenously produced free radical synthesized from L-arginine by one of three nitric oxide synthase isoforms: neuronal, endothelial, and inducible NOS.
“Nitric oxide is an endogenously produced free radical synthesized from L-arginine by one of three isoforms of nitric oxide synthase (NOS): neuronal NOS (nNOS), endothelial NOS (eNOS), and inducible NOS (iNOS).211”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [211] Walford G., 2003, J. Thromb. Haemost. source
Not checked in the free run.
May combine two claims.
InterpretationreasoningDifferences in outcomes among dexamethasone studies may be due to differences in polymer composition, dexamethasone release kinetics, and/or total dexamethasone payload.
“The difference in the outcome of these studies may be the result of differences in polymer composition, DX release kinetics, and or total DX payload, clearly indicating the importance of many biomaterial parameters on tissue biocompatibility.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationWithin 24 h, biosensors in control mice had large reductions in sensitivity, while mice receiving daily dexamethasone injection at the sensor site sustained sensitivity and functionality through 2 weeks regardless of dexamethasone concentration.
“Within 24 h biosensors in control mice suffered large reductions in sensitivity while mice receiving the daily DX injection at the sensor site experienced sustained sensitivity and functionality through 2 weeks, regardless of DX concentration.192”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [192] Klueh U., 2007, J. Diabetes Sci. Technol. source
Not checked in the free run.
May combine two claims.
PremisecitationComputational modeling showed that a polyimide material reduced applied strain to surrounding tissue by 94%, while a theoretical 6 MPa material reduced strain by two orders of magnitude.
“the polyimide material demonstrated a 94% reduction in applied strain to the surrounding tissue, while strain with the theoretical 6 MPa material was reduced by two orders of magnitude.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [169] Subbaroyan J., 2005, J. Neural Eng. source
Not checked in the free run.
May combine two claims.
PremisecitationPLGA particles are simple to synthesize, enable slow dexamethasone release, and biodegrade over 2-3 months.
“These particles are simple to synthesize, enable slow DX release, and biodegrade over 2–3 months.183”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [183] Burgess D., 1994
Not checked in the free run.
Probably not a substantial claim: may not pass S1 (asserted). May combine two claims.
PremisereasoningThe combined use of dexamethasone and VEGF was hypothesized to decrease inflammation and enhance vascularization.
“The combined use of these factors was thus hypothesized to decrease inflammation and enhance vascularization.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisenone givenDexamethasone is a glucocorticoid that reduces inflammation.
“Dexamethasone (DX) is a glucocorticoid that reduces inflammation.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationreasoningResearch on nitric oxide storage and release, and on combining nitric oxide release with enzymatic glucose sensing, is still at an early stage.
“research to date is still in early stages with respect to NO storage and release, and combining the chemistry of NO release with enzymatic glucose sensing.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S4 (based).
Interpretationnone givenNew strategies that direct rather than avoid the foreign body response by actively releasing drugs and/or the body's own wound-healing signaling mediators have opened a unique path to alter the natural host response.
“New strategies for directing rather than avoiding the FBR by the active release of drugs and/or the body’s own signaling mediators of wound healing have created a unique path to alter the natural host response.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationCarreau et al. reported reduced leukocyte adhesion at elevated nitric oxide concentrations, suggesting that nitric oxide could reduce localization of inflammatory cells at the device-tissue interface.
“Carreau et al. reported reduced leukocyte adhesion at elevated NO concentrations, suggesting NO could reduce localization of inflammatory cells at the device-tissue interface.216”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [216] Carreau A., 2011, Exp. Cell Res. source
Not checked in the free run.
May combine two claims.
InterpretationcitationThe anti-inflammatory effect correlated with nitric oxide release duration, indicating that benefits may only persist while the interface is releasing nitric oxide, in contrast to Hetrick et al. where long-term reduction in inflammation was observed after cessation of release.
“The anti-inflammation correlated with the NO-release duration indicating that the observed benefits may only persist as long as the interface is releasing NO, in contrast to observations by Hetrick et al. where long-term reduction in inflammation were observed after cessation of NO release.103,238”
Quote in the paperSubstantial claim0 of 2 sources checkedMay combine two claims.
PremisecitationIn Nichols et al.'s study, collagen encapsulation decreased at 3 and 6 weeks, with the largest effect seen for the highest payloads and longest release.
“Collagen encapsulation was reduced at 3 and 6 weeks, and the greatest effect was observed for the largest payloads and longest release.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [240] Nichols S. P., 2012, Biomaterials source
Not checked in the free run.
May combine two claims.
PremisecitationMultiple reports indicate that nitric oxide serves as an angiogenic signaling molecule, up-regulating VEGF production and increasing blood vessel growth.
“Multiple reports indicate that NO serves as an angiogenic signaling model, up-regulating VEGF production and increasing blood vessel growth.213–214”
Quote in the paperSubstantial claim0 of 2 sources checkedMay combine two claims.
PremisecitationHetrick et al. found that nitric oxide reduced collagen encapsulation by about 20-25% versus controls at 3 and 6 weeks, mitigated inflammation, and appeared to enhance vascular density at 1 and 3 weeks.
“In addition to reduced collagen encapsulation (~20–25% vs. controls) observed at 3 and 6 weeks, the NO mitigated inflammation (determined by reduced inflammatory cells near the implant) and appeared to enhance vascular density at 1 and 3 weeks.238”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [238] Hetrick E. M., 2007, Biomaterials source
Not checked in the free run.
The paper relies on this without support.
Traditional finger-prick glucose monitoring yields only instantaneous readings and cannot provide advance warning of hyperglycemic or hypoglycemic events.
“such monitoring only provides instantaneous blood glucose concentrations that are unable to warn of hyperglycemic or hypoglycemic events in advance.”
The paper relies on this without support.
Finger-prick sample collection is inconvenient and leads to poor patient compliance.
“Additionally, the sample collection (i.e., finger prick) method is inconvenient resulting in poor patient compliance.”
The authors state this as an assumption.
CGM systems estimate blood glucose by assuming interstitial fluid glucose is similar enough to blood glucose.
“CGM systems inherently estimate the blood glucose concentration by assuming the concentration of glucose in interstitial fluids will be similar enough.”
The paper relies on this without support.
The foreign body response is a major hurdle for continuous glucose monitoring performance.
“address the major hurdles related to the FBR.”
The paper relies on this without support.
The outer sensor membrane protects the enzyme.
“the outer sensor membrane that serves to protect the enzyme, tune response, and ultimately is responsible for the magnitude of the FBR”
The paper relies on this without support.
The outer sensor membrane tunes the sensor response.
“the outer sensor membrane that serves to protect the enzyme, tune response, and ultimately is responsible for the magnitude of the FBR”
The paper relies on this without support.
The outer sensor membrane determines the magnitude of the foreign body response.
“the outer sensor membrane that serves to protect the enzyme, tune response, and ultimately is responsible for the magnitude of the FBR”
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Extended-time CGM generally requires 2-3 weeks stabilization period after surgery and are larger than subcutaneous counterparts.
“The latter, generally requires 2-3 weeks stabilization period after surgery and are larger than the subcutaneous counterparts 88.”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [88]
Section 2.2 says that fully subcutaneous sensors require surgery and a roughly 2–3-week stabilization period afterward. It says those sensors are larger than percutaneous CGM systems, not larger than subcutaneous counterparts; the claim changes the comparator. (LLM, conf=0.89)
Experimental — accuracy not yet measuredBLE allows transferring state information in small blocks of data at regular intervals, with the processor operating in a low power mode.
“This protocol allows transferring state information in small blocks of data at regular intervals, where the processor operates in a low power mode.107”
From Wearables in Medicine (2018) · cites this paper as [107]
The cited paper’s section on continuous glucose monitoring technologies (§2.2) describes glucose sensors, while its discussion of sensor performance (§3.4) addresses calibration and physiological lag. Neither the supplied passages nor searches for BLE, Bluetooth, wireless communication, small data blocks, and low-power processor operation found a passage addressing the claimed protocol behavior. (LLM, conf=0.76)
Experimental — accuracy not yet measuredFor materials larger than 100 μm, greater thickness is generally thought to produce proportionally stronger foreign body responses and fibrosis.
“At the macro level (>100 μm in size), it is generally held that thicker materials produce a proportionally higher magnitude of foreign body responses and fibrosis3, 21.”
From Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates (2015) · cites this paper as [3]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Conclusion overlooks reported DX-release sensor results
MinorThe paper says the effect of DX release on glucose biosensor performance has not been evaluated, yet it earlier reports sensitivity results for DX-releasing glucose biosensors against controls.
“Furthermore, studies evaluating the benefits of VEGF-, DX-, or VEGF/DX-release on the analytical performance of glucose biosensors have not been evaluated.”
“DX-releasing glucose biosensors retained >50% of their original sensitivity 2 weeks after implantation, the sensitivity of control membranes dropped to 15–42% of their original levels.187”
Cites
Exploring the full spectrum of macrophage activation
Mosser, D. M., & Edwards, J. P. (2008) · Nature Reviews Immunology · doi:10.1038/nri2448 · Cited by 9,144 · see citing works
Hydrogels for Tissue Engineering
Lee, K. Y., & Mooney, D. J. (2001) · Chemical Reviews · doi:10.1021/cr000108x · Cited by 5,295 · see citing works
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · see citing works
Electrospinning: A Fascinating Method for the Preparation of Ultrathin Fibers
Greiner, A., & Wendorff, J. H. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200604646 · Cited by 4,260 · see citing works
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945 · see citing works
Vascular Endothelial Growth Factor: Basic Science and Clinical Progress
Ferrara, N. (2004) · Endocrine Reviews · doi:10.1210/er.2003-0027 · Cited by 3,707 · see citing works
Regulation of Wound Healing by Growth Factors and Cytokines
WERNER, S., & GROSE, R. (2003) · Physiological Reviews · doi:10.1152/physrev.2003.83.3.835 · Cited by 3,629 · see citing works
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498 · see citing works
Antiinflammatory Action of Glucocorticoids — New Mechanisms for Old Drugs
Rhen, T., & Cidlowski, J. A. (2005) · New England Journal of Medicine · doi:10.1056/nejmra050541 · Cited by 3,149 · see citing works
On the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772 · see citing works
Coutinho, A. E., & Chapman, K. E. (2011) · Molecular and Cellular Endocrinology · doi:10.1016/j.mce.2010.04.005 · Cited by 1,815 · see citing works
Myotubes differentiate optimally on substrates with tissue-like stiffness
Engler, A. J., Griffin, M. A., Sen, S., Bönnemann, C. G., Sweeney, H. L., & Discher, D. E. (2004) · The Journal of Cell Biology · doi:10.1083/jcb.200405004 · Cited by 1,743 · see citing works
Encyclopedia of pharmaceutical technology
(2003) · Choice Reviews Online · doi:10.5860/choice.40-6157 · Cited by 1,741 · see citing works
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707 · see citing works
Mediation of biomaterial-cell interactions by adsorbed proteins: a review
Wilson, C. J., Clegg, R. E., Leavesley, D. I., & Pearcy, M. J. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.1 · Cited by 1,696 · see citing works
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465 · see citing works
Electrospun nanofibers: solving global issues
Ramakrishna, S., Fujihara, K., Teo, W. E., Yong, T., Ma, Z., & Ramaseshan, R. (2006) · Materials Today · doi:10.1016/s1369-7021(06)71389-x · Cited by 1,420 · see citing works
Nitric oxide donors: chemical activities and biological applications
Wang, P. G., Xian, M., Tang, X., Wu, X., Wen, Z., Cai, T., & Janczuk, A. J. (2002) · Chemical Reviews · doi:10.1021/cr000040l · Cited by 1,337 · see citing works
Updike, S. J., & Hicks, G. P. (1967) · Nature · doi:10.1038/214986a0 · Cited by 1,335 · see citing works
Nitric Oxide Synthases: Properties and Catalytic Mechanism
Griffith, O. W., & Stuehr, D. J. (1995) · Annual Review of Physiology · doi:10.1146/annurev.ph.57.030195.003423 · Cited by 1,311 · see citing works
Reducing implant-related infections: active release strategies
Hetrick, E. M., & Schoenfisch, M. H. (2006) · Chemical Society Reviews · doi:10.1039/b515219b · Cited by 1,201 · see citing works
Self-citationElectrochemical non-enzymatic glucose sensors
Park, S., Boo, H., & Chung, T. D. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.05.080 · Cited by 1,162 · see citing works
Nitric oxide release: Part II. Therapeutic applications
Carpenter, A. W., & Schoenfisch, M. H. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15273h · Cited by 964 · see citing works
Self-citationHome blood glucose biosensors: a commercial perspective
Newman, J. D., & Turner, A. P. F. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.012 · Cited by 901 · see citing works
Brown, L. F., Yeo, K. T., Berse, B., Yeo, T. K., Senger, D. R., Dvorak, H. F., & van de Water, L. (1992) · The Journal of experimental medicine · doi:10.1084/jem.176.5.1375 · Cited by 878 · see citing works
Glucose Biosensors: 40 Years of Advances and Challenges
Wang, J. (2001) · Electroanalysis · doi:10.1002/1521-4109(200108)13:12 · Cited by 765 · see citing works
Regulation of Vascular Endothelial Growth Factor Expression in Cultured Keratinocytes.
Frank, S., Hübner, G., Breier, G., Longaker, M. T., Greenhalgh, D. G., & Werner, S. (1995) · Journal of Biological Chemistry · doi:10.1074/jbc.270.21.12607 · Cited by 764 · see citing works
Proangiogenic scaffolds as functional templates for cardiac tissue engineering
Madden, L. R., Mortisen, D. J., Sussman, E. M., Dupras, S. K., Fugate, J. A., Cuy, J. L., Hauch, K. D., Laflamme, M. A., Murry, C. E., & Ratner, B. D. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1006442107 · Cited by 662 · see citing works
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660 · see citing works
Toward a Glucose Biosensor Based on Surface-Enhanced Raman Scattering
Shafer-Peltier, K. E., Haynes, C. L., Glucksberg, M. R., & Van Duyne, R. P. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028255v · Cited by 653 · see citing works
The molecular biology of chronic wounds and delayed healing in diabetes
Blakytny, R., & Jude, E. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2006.01773.x · Cited by 632 · see citing works
Vascular permeability, vascular hyperpermeability and angiogenesis
Nagy, J. A., Benjamin, L. E., Zeng, H., Dvořàk, A. M., & Dvorak, H. F. (2008) · Angiogenesis · doi:10.1007/s10456-008-9099-z · Cited by 629 · see citing works
Fluorescence-based glucose sensors
Pickup, J. C., Hussain, F., Evans, N. D., Rolinski, O. J., & Birch, D. J. S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.002 · Cited by 616 · see citing works
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584 · see citing works
Non-invasive glucose monitoring technology in diabetes management: A review
Vashist, S. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.043 · Cited by 575 · see citing works
Degani, Y., & Heller, A. (1987) · The Journal of Physical Chemistry · doi:10.1021/j100290a001 · Cited by 574 · see citing works
An enzyme electrode for the amperometric determination of glucose
Guilbault, G. G., & Lubrano, G. J. (1973) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)82476-4 · Cited by 572 · see citing works
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543 · see citing works
Neovascularization of synthetic membranes directed by membrane microarchitecture
Brauker, J. H., Carr‐Brendel, V. E., Martinson, L. A., Crudele, J., Johnston, W. D., & Johnson, R. C. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820291208 · Cited by 517 · see citing works
The Chemistry of S-Nitrosothiols
Williams, D. L. H. (1999) · Accounts of Chemical Research · doi:10.1021/ar9800439 · Cited by 499 · see citing works
Nitric oxide release: Part I. Macromolecular scaffolds
Riccio, D. A., & Schoenfisch, M. H. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15272j · Cited by 475 · see citing works
Self-citationA review of the immobilization of enzymes in electropolymerized films
Barlett, P. N., & Cooper, J. M. (1993) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(93)80001-x · Cited by 472 · see citing works
Hrabie, J. A., & Keefer, L. K. (2002) · Chemical Reviews · doi:10.1021/cr000028t · Cited by 466 · see citing works
Enzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434 · see citing works
Handbook of non-invasive methods and the skin
Guy, R. H. (1996) · Journal of Controlled Release · doi:10.1016/0168-3659(96)01365-x · Cited by 414 · see citing works
Cellular and Molecular Dynamics in the Foreign Body Reaction
Luttikhuizen, D. T., Harmsen, M. C., & Luyn, M. J. A. V. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.1955 · Cited by 396 · see citing works
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390 · see citing works
Tierney, M. J., Tamada, J. A., Potts, R. O., Jovanovic, L., & Garg, S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00189-0 · Cited by 390 · see citing works
Nitric oxide and wound repair: role of cytokines?
Schwentker, A., Vodovotz, Y., Weller, R., & Billiar, T. R. (2002) · Nitric Oxide · doi:10.1016/s1089-8603(02)00002-2 · Cited by 386 · see citing works
Yonzon, C. R., Haynes, C. L., Zhang, X., Walsh, & Van Duyne, R. P. (2004) · Analytical Chemistry · doi:10.1021/ac035134k · Cited by 376 · see citing works
Photonic Crystal Glucose-Sensing Material for Noninvasive Monitoring of Glucose in Tear Fluid
Alexeev, V. L., Das, S., Finegold, D. N., & Asher, S. A. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.039701 · Cited by 370 · see citing works
Subbaroyan, J., Martin, D. C., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/006 · Cited by 368 · see citing works
Jones, J. A., Chang, D. T., Meyerson, H., Colton, E., Kwon, I. K., Matsuda, T., & Anderson, J. M. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31221 · Cited by 352 · see citing works
A numerical‐experimental method to characterize the non‐linear mechanical behaviour of human skin
Hendriks, F. M., Brokken, D., Van Eemeren, J. T. W. M., Oomens, C. W. J., Baaijens, F. P. T., & Horsten, J. B. A. M. (2003) · Skin Research and Technology · doi:10.1034/j.1600-0846.2003.00019.x · Cited by 347 · see citing works
Shoji, E., & Freund, M. S. (2001) · Journal of the American Chemical Society · doi:10.1021/ja005906j · Cited by 344 · see citing works
Furchgott, R. F. (1999) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19990712)38:13/14 · Cited by 339 · see citing works
Jhon, M. S., & Andrade, J. D. (1973) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820070604 · Cited by 326 · see citing works
Zhao, Q., Topham, N., Anderson, J. M., Hiltner, A., Lodoen, G., & Payet, C. R. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250205 · Cited by 318 · see citing works
WEARABLE ARTIFICIAL ENDOCRINE PANCREAS WITH NEEDLE-TYPE GLUCOSE SENSOR
Shichiri, M., Yamasaki, Y., Kawamori, R., Hakui, N., & Abe, H. (1982) · The Lancet · doi:10.1016/s0140-6736(82)92788-x · Cited by 314 · see citing works
Evaluating the Accuracy of Continuous Glucose-Monitoring Sensors
Kovatchev, B. P., Gonder-Frederick, L. A., Cox, D. J., & Clarke, W. L. (2004) · Diabetes Care · doi:10.2337/diacare.27.8.1922 · Cited by 312 · see citing works
Long-term in vivo glucose monitoring using fluorescent hydrogel fibers
Heo, Y. J., Shibata, H., Okitsu, T., Kawanishi, T., & Takeuchi, S. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1104954108 · Cited by 311 · see citing works
Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
Bindra, D. S., Zhang, Y., Wilson, G. S., Sternberg, R., Thevenot, D. R., Moatti, D., & Reach, G. (1991) · Analytical Chemistry · doi:10.1021/ac00017a008 · Cited by 309 · see citing works
Nitric Oxide in Vascular Biology
Walford, G., & Loscalzo, J. (2003) · Journal of Thrombosis and Haemostasis · doi:10.1046/j.1538-7836.2003.00345.x · Cited by 302 · see citing works
Noninvasive Blood Glucose Monitoring With Optical Coherence Tomography
Larin, K. V., Eledrisi, M. S., Motamedi, M., & Esenaliev, R. O. (2002) · Diabetes Care · doi:10.2337/diacare.25.12.2263 · Cited by 293 · see citing works
Injectable hydrogel microbeads for fluorescence-based in vivo continuous glucose monitoring
Shibata, H., Heo, Y. J., Okitsu, T., Matsunaga, Y. T., Kawanishi, T., & Takeuchi, S. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1006911107 · Cited by 287 · see citing works
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285 · see citing works
Minireview: Latest Perspectives on Antiinflammatory Actions of Glucocorticoids
De Bosscher, K., & Haegeman, G. (2009) · Molecular Endocrinology · doi:10.1210/me.2008-0283 · Cited by 284 · see citing works
Gibney, M. A., Arce, C. H., Byron, K. J., & Hirsch, L. J. (2010) · Current Medical Research and Opinion · doi:10.1185/03007995.2010.481203 · Cited by 283 · see citing works
Tura, A., Maran, A., & Pacini, G. (2007) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2006.10.027 · Cited by 283 · see citing works
Barone, P. W., Parker, R. S., & Strano, M. S. (2005) · Analytical Chemistry · doi:10.1021/ac0511997 · Cited by 279 · see citing works
Potentiometric Saccharide Detection Based on the p K a Changes of Poly(aniline boronic acid)
Shoji, E., & Freund, M. S. (2002) · Journal of the American Chemical Society · doi:10.1021/ja0267371 · Cited by 277 · see citing works
Anti-inflammatory functions of glucocorticoid-induced genes
Clark, A. R. (2007) · Molecular and Cellular Endocrinology · doi:10.1016/j.mce.2007.04.013 · Cited by 272 · see citing works
Raman spectroscopy for noninvasive glucose measurements
Enejder, A. M. K., Scecina, T. G., Oh, J., Hunter, M., Shih, W., Šašić, S., Horowitz, G. L., & Feld, M. S. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1920212 · Cited by 272 · see citing works
van Tienen, T. G., Heijkants, R. G. J. C., Buma, P., de Groot, J. H., Pennings, A. J., & Veth, R. P. H. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00280-0 · Cited by 270 · see citing works
Current development in non-invasive glucose monitoring
Ferrante do Amaral, C. E., & Wolf, B. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.003 · Cited by 269 · see citing works
Hickey, T., Kreutzer, D., Burgess, D. J., & Moussy, F. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00291-5 · Cited by 268 · see citing works
Cooke, J. P. (2003) · Atherosclerosis Supplements · doi:10.1016/s1567-5688(03)00034-5 · Cited by 266 · see citing works
Proinflammatory functions of vascular endothelial growth factor in alloimmunity
Reinders, M. E. J., Sho, M., Izawa, A., Wang, P., Mukhopadhyay, D., Koss, K. E., Geehan, C. S., Luster, A. D., Sayegh, M. H., & Briscoe, D. M. (2003) · Journal of Clinical Investigation · doi:10.1172/jci17712 · Cited by 251 · see citing works
Synthesis of Nitric Oxide-Releasing Silica Nanoparticles
Shin, J. H., O’Neal, S., & Schoenfisch, M. H. (2007) · Journal of the American Chemical Society · doi:10.1021/ja0674338 · Cited by 250 · see citing works
Self-citationEdelman, J. L., Lutz, D., & Castro, M. R. (2005) · Experimental Eye Research · doi:10.1016/j.exer.2004.09.013 · Cited by 246 · see citing works
Glucose monitoring by reverse iontophoresis
Potts, R. O., Tamada, J. A., & Tierney, M. J. (2002) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.210 · Cited by 244 · see citing works
Cao, H., Mchugh, K., Chew, S. Y., & Anderson, J. M. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32609 · Cited by 243 · see citing works
Comparison of the Numerical and Clinical Accuracy of Four Continuous Glucose Monitors
Kovatchev, B. P., Anderson, S. M., Heinemann, L., & Clarke, W. L. (2008) · Diabetes Care · doi:10.2337/dc07-2401 · Cited by 236 · see citing works
Long-term engraftment of hepatocytes transplanted on biodegradable polymer sponges
Mooney, D. J., Sano, K., Kaufmann, P. M., Majahod, K., Schloo, B. L., Vacanti, J. P., & Langer, R. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19971205)37:3 · Cited by 233 · see citing works
Concurrent delivery of dexamethasone and VEGF for localized inflammation control and angiogenesis
Patil, S. D., Papadmitrakopoulos, F., & Burgess, D. J. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.10.013 · Cited by 230 · see citing works
Accuracy of the 5-Day FreeStyle Navigator Continuous Glucose Monitoring System
Weinstein, R. L., Schwartz, S. L., Brazg, R., Bugler, J., Peyser, T. A., & McGarraugh, G. V. (2007) · Diabetes Care · doi:10.2337/dc06-1602 · Cited by 228 · see citing works
Initial in vivo experience with steady‐state subzone‐based MR elastography of the human breast
Van Houten, E. E. W., Doyley, M. M., Kennedy, F. E., Weaver, J. B., & Paulsen, K. D. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10232 · Cited by 224 · see citing works
Implanted Electrochemical Glucose Sensors for the Management of Diabetes
Heller, A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.153 · Cited by 215 · see citing works
Davies, K. M., Wink, D. A., Saavedra, J. E., & Keefer, L. K. (2001) · Journal of the American Chemical Society · doi:10.1021/ja002899q · Cited by 208 · see citing works
Nitric oxide-releasing sol–gels as antibacterial coatings for orthopedic implants
Nablo, B. J., Rothrock, A. R., & Schoenfisch, M. H. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.03.031 · Cited by 207 · see citing works
Self-citationDelays in Minimally Invasive Continuous Glucose Monitoring Devices: A Review of Current Technology
Keenan, D. B., Mastrototaro, J. J., Voskanyan, G., & Steil, G. M. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300528 · Cited by 198 · see citing works
Polymer‐Based Nitric Oxide Therapies: Recent Insights for Biomedical Applications
Jen, M. C., Serrano, M. C., van Lith, R., & Ameer, G. A. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201101707 · Cited by 194 · see citing works
The chick chorioallantoic membrane as a novel in vivo model for the testing of biomaterials
Valdes, T. I., Kreutzer, D. L., & Moussy, F. G. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10152 · Cited by 192 · see citing works
Measurement of glucose in diabetic subjects using noninvasive transdermal extraction
Tamada, J. A., Bohannon, N. J. V., & Potts, R. O. (1995) · Nature Medicine · doi:10.1038/nm1195-1198 · Cited by 182 · see citing works
Koschwanez, H. E., & Reichert, W. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.034 · Cited by 181 · see citing works
<i>In vivo</i> biocompatibility studies. I. The cage implant system and a biodegradable hydrogel
Marchant, R., Hiltner, A., Hamlin, C., Rabinovitch, A., Slobodkin, R., & Anderson, J. M. (1983) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820170209 · Cited by 181 · see citing works
Jamieson, A. M., Yu, S., Annicelli, C. H., & Medzhitov, R. (2010) · Cell Host & Microbe · doi:10.1016/j.chom.2010.01.010 · Cited by 180 · see citing works
Function of an Implanted Tissue Glucose Sensor for More than 1 Year in Animals
Gough, D. A., Kumosa, L. S., Routh, T. L., Lin, J. T., & Lucisano, J. Y. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3001148 · Cited by 179 · see citing works
In-Vivo Electrochemistry: What Can We Learn about Living Systems?
Wilson, G. S., & Johnson, M. A. (2008) · Chemical Reviews · doi:10.1021/cr068082i · Cited by 178 · see citing works
Ward, W. K., Slobodzian, E. P., Tiekotter, K. L., & Wood, M. D. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00160-6 · Cited by 176 · see citing works
A fibrinogen-based precision microporous scaffold for tissue engineering
Linnes, M. P., Ratner, B. D., & Giachelli, C. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.08.020 · Cited by 174 · see citing works
Wu, W.-S., Wang, F.-S., Yang, K. D., Huang, C.-C., & Kuo, Y.-R. (2006) · Journal of Investigative Dermatology · doi:10.1038/sj.jid.5700274 · Cited by 174 · see citing works
Quinn, C. P., Pathak, C. P., Heller, A., & Hubbell, J. A. (1995) · Biomaterials · doi:10.1016/0142-9612(95)98856-9 · Cited by 172 · see citing works
A paradigm shift: biomaterials that heal
Ratner, B. D. (2007) · Polymer International · doi:10.1002/pi.2319 · Cited by 162 · see citing works
Viscoelastic response of human skin to low magnitude physiologically relevant shear
Holt, B., Tripathi, A., & Morgan, J. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.06.008 · Cited by 161 · see citing works
Moussy, F. G., Harrison, D. J., O'Brien, D. W., & Rajotte, R. V. (1993) · Analytical Chemistry · doi:10.1021/ac00063a023 · Cited by 158 · see citing works
Reduced foreign body response at nitric oxide-releasing subcutaneous implants
Hetrick, E. M., Prichard, H. L., Klitzman, B., & Schoenfisch, M. H. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.06.036 · Cited by 158 · see citing works
Self-citationCaduff, A., Dewarrat, F., Talary, M., Stalder, G., Heinemann, L., & Feldman, Y. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.031 · Cited by 155 · see citing works
Biomaterial–microvasculature interactions
Sieminski, A. L., & Gooch, K. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00149-6 · Cited by 155 · see citing works
Fluorescence Glucose Detection: Advances Toward the Ideal In Vivo Biosensor
Moschou, E. A., Sharma, B. V., Deo, S. K., & Daunert, S. (2004) · Journal of Fluorescence · doi:10.1023/b:jofl.0000039341.64999.83 · Cited by 154 · see citing works
Rebrin, K., Sheppard, N. F., & Steil, G. M. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400507 · Cited by 152 · see citing works
The Microcirculation and Inflammation: Site of Action for Glucocorticoids
Perretti, M., & Ahluwalia, A. (2000) · Microcirculation · doi:10.1111/j.1549-8719.2000.tb00117.x · Cited by 146 · see citing works
Sachedina, N., & Pickup, J. C. (2003) · Diabetic Medicine · doi:10.1046/j.1464-5491.2003.01037.x · Cited by 142 · see citing works
Yu, B., Long, N., Moussy, Y., & Moussy, F. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.11.002 · Cited by 141 · see citing works
Zhao, Q. H., McNally, A. K., Rubin, K. R., Renier, M., Wu, Y., Rose‐Caprara, V., Anderson, J. M., Hiltner, A., Urbanski, P., & Stokes, K. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270311 · Cited by 140 · see citing works
Zhao, Q., Egashira, K., Inoue, S., Usui, M., Kitamoto, S., Ni, W., Ishibashi, M., Hiasa, K.-I., Ichiki, T., Shibuya, M., et al. (2002) · Circulation · doi:10.1161/hc0902.104718 · Cited by 136 · see citing works
Patil, S. D., Papadimitrakopoulos, F., & Burgess, D. J. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.887 · Cited by 135 · see citing works
A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration.
Updike, S. J., Shults, M. C., Gilligan, B. J., & Rhodes, R. K. (2000) · Diabetes Care · doi:10.2337/diacare.23.2.208 · Cited by 135 · see citing works
Progress Toward an In Vivo Surface-Enhanced Raman Spectroscopy Glucose Sensor
Lyandres, O., Yuen, J. M., Shah, N. C., Duyne, R. P. V., Walsh, J. T., & Glucksberg, M. R. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2007.0288 · Cited by 135 · see citing works
Sol−Gel Derived Nitric-Oxide Releasing Materials that Reduce Bacterial Adhesion
Nablo, B. J., Chen, T.-Y., & Schoenfisch, M. H. (2001) · Journal of the American Chemical Society · doi:10.1021/ja0165077 · Cited by 134 · see citing works
Self-citationRegulation of Vascular Endothelial Growth Factor Synthesis by Nitric Oxide: Facts and Controversies
Dulak, J., & Józkowicz, A. (2003) · Antioxidants & Redox Signaling · doi:10.1089/152308603321223612 · Cited by 130 · see citing works
Norton, L. W., Koschwanez, H. E., Wisniewski, N. A., Klitzman, B., & Reichert, W. M. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31088 · Cited by 128 · see citing works
Reverse Iontophoresis: Development of a Noninvasive Approach for Glucose Monitoring
Rao, G., Glikfeld, P., & Guy, R. H. (1993) · Pharmaceutical Research · doi:10.1023/a:1018926215306 · Cited by 126 · see citing works
Biocompatible, glucose-permeable hydrogel for in situ coating of implantable biosensors
Quinn, C. A. P., Connor, R. E., & Heller, A. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00125-7 · Cited by 126 · see citing works
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500317 · Cited by 125 · see citing works
On the parameters affecting the characteristics of the “wired” glucose oxidase anode
Mano, N., Mao, F., & Heller, A. (2004) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2004.08.014 · Cited by 121 · see citing works
Wisniewski, N., Klitzman, B. M., Miller, B., & Reichert, W. M. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20011215)57:4 · Cited by 120 · see citing works
Chen, X., Matsumoto, N., Hu, Y., & Wilson, G. S. (2002) · Analytical Chemistry · doi:10.1021/ac015628m · Cited by 120 · see citing works
Protein interactions with subcutaneously implanted biosensors
Gifford, R., Kehoe, J. J., Barnes, S. L., Kornilayev, B. A., Alterman, M. A., & Wilson, G. S. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.033 · Cited by 117 · see citing works
ChemInform Abstract: Nitric Oxide Release. Part 2. Therapeutic Applications
Carpenter, A. W., & Schoenfisch, M. H. (2012) · ChemInform · doi:10.1002/chin.201231269 · Cited by 115 · see citing works
Self-citation*The Diabetes Research in Children Network (DirecNet) Study Group (2004) · Diabetes Care · doi:10.2337/diacare.27.3.722 · Cited by 114 · see citing works
Machein, Kullmer, Rönicke, Machein, Krieg, Damert, Breier, Risau, & Plate (1999) · Neuropathology and Applied Neurobiology · doi:10.1046/j.1365-2990.1999.00166.x · Cited by 113 · see citing works
Karp, R. D., Johnson, K. H., Buoen, L. C., Ghobrial, H. K. G., Brand, I., & Brand, K. G. (1973) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/51.4.1275 · Cited by 112 · see citing works
In vivo cytokine-associated responses to biomaterials
Schutte, R. J., Xie, L., Klitzman, B., & Reichert, W. M. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.09.026 · Cited by 111 · see citing works
Nitric oxide-releasing S-nitrosothiol-modified xerogels
Riccio, D. A., Dobmeier, K. P., Hetrick, E. M., Privett, B. J., Paul, H. S., & Schoenfisch, M. H. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.05.006 · Cited by 107 · see citing works
Self-citationLowry, J. P., O'Neill, R. D., Boutelle, M. G., & Fillenz, M. (1998) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.1998.70010391.x · Cited by 105 · see citing works
Modulus-dependent macrophage adhesion and behavior
Irwin, E. F., Saha, K., Rosenbluth, M., Gamble, L. J., Castner, D. G., & Healy, K. E. (2008) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856208786052407 · Cited by 105 · see citing works
Use of hydrogel coating to improve the performance of implanted glucose sensors
Yu, B., Wang, C., Ju, Y. M., West, L., Harmon, J., Moussy, Y., & Moussy, F. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.11.010 · Cited by 105 · see citing works
A glucose-sensing contact lens: from bench top to patient
Badugu, R., Lakowicz, J. R., & Geddes, C. D. (2005) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2004.12.007 · Cited by 105 · see citing works
S‐nitrosoglutathione‐containing hydrogel accelerates rat cutaneous wound repair
Amadeu, T. P., Seabra, A. B., Oliveira, M. D., & Monte‐Alto‐Costa, A. (2007) · Journal of the European Academy of Dermatology and Venereology · doi:10.1111/j.1468-3083.2006.02032.x · Cited by 105 · see citing works
Inorganic/Organic Hybrid Silica Nanoparticles as a Nitric Oxide Delivery Scaffold
Shin, J. H., & Schoenfisch, M. H. (2007) · Chemistry of Materials · doi:10.1021/cm702526q · Cited by 104 · see citing works
Self-citationPreparation of Nitric Oxide (NO)-Releasing Sol−Gels for Biomaterial Applications
Marxer, S. M., Rothrock, A. R., Nablo, B. J., Robbins, M. E., & Schoenfisch, M. H. (2003) · Chemistry of Materials · doi:10.1021/cm034347n · Cited by 104 · see citing works
Self-citationNorton, L. W., Tegnell, E., Toporek, S. S., & Reichert, W. M. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.069 · Cited by 104 · see citing works
Hetrick, E. M., & Schoenfisch, M. H. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.01.006 · Cited by 104 · see citing works
Self-citationHelton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500318 · Cited by 102 · see citing works
Monocyte, macrophage and foreign body giant cell interactions with molecularly engineered surfaces
Anderson, J. M., Defife, K., Mcnally, A., collier, T., & jenney, C. (1999) · Journal of Materials Science: Materials in Medicine · doi:10.1023/a:1008976531592 · Cited by 100 · see citing works
Diridollou, S., Black, D., Lagarde, J. M., Gall, Y., Berson, M., Vabre, V., Patat, F., & Vaillant, L. (2000) · International Journal of Cosmetic Science · doi:10.1111/j.1468-2494.2000.00037.x · Cited by 99 · see citing works
Bhardwaj, U., Sura, R., Papadimitrakopoulos, F., & Burgess, D. J. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100103 · Cited by 99 · see citing works
Pishko, M. V., Katakis, I., Lindquist, S., Ye, L., Gregg, B. A., & Heller, A. (1990) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199000821 · Cited by 99 · see citing works
Nitric Oxide Donor Improves Healing if Applied on Inflammatory and Proliferative Phase
Amadeu, T. P., Seabra, A. B., de Oliveira, M. G., & Monte‐Alto‐Costa, A. (2007) · Journal of Surgical Research · doi:10.1016/j.jss.2007.10.015 · Cited by 96 · see citing works
Mediation of <i>in vivo</i> glucose sensor inflammatory response via nitric oxide release
Gifford, R., Batchelor, M. M., Lee, Y., Gokulrangan, G., Meyerhoff, M. E., & Wilson, G. S. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30359 · Cited by 96 · see citing works
Shichiri, M., Asakawa, N., Yamasaki, Y., Kawamori, R., & Abe, H. (1986) · Diabetes Care · doi:10.2337/diacare.9.3.298 · Cited by 96 · see citing works
Nonenzymatic continuous glucose monitoring in human whole blood using electrified nanoporous Pt
Park, S., Park, S., Jeong, R.-A., Boo, H., Park, J., Kim, H. C., & Chung, T. D. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.10.033 · Cited by 96 · see citing works
A Novel Noninvasive Blood Glucose Monitor
Malchoff, C. D., Shoukri, K., Landau, J. I., & Buchert, J. M. (2002) · Diabetes Care · doi:10.2337/diacare.25.12.2268 · Cited by 96 · see citing works
Amperometric Glucose Sensors: Sources of Error and Potential Benefit of Redundancy
Castle, J. R., & Ward, W. K. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400127 · Cited by 95 · see citing works
Time‐dependent inactivation of immobilized glucose oxidase and catalase
Tse, P. H. S., & Gough, D. A. (1987) · Biotechnology and Bioengineering · doi:10.1002/bit.260290607 · Cited by 95 · see citing works
Stöber Synthesis of Nitric Oxide-Releasing S-Nitrosothiol-Modified Silica Particles
Riccio, D. A., Nugent, J. L., & Schoenfisch, M. H. (2011) · Chemistry of Materials · doi:10.1021/cm102510q · Cited by 93 · see citing works
Self-citationZhang, Y., & Wilson, G. S. (1993) · Analytica Chimica Acta · doi:10.1016/0003-2670(93)85009-9 · Cited by 92 · see citing works
Turner, R. F. B., Harrison, D. J., & Rojotte, R. V. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90003-s · Cited by 91 · see citing works
Pendra goes Dutch: lessons for the CE mark in Europe
Wentholt, I. M. E., Hoekstra, J. B. L., Zwart, A., & DeVries, J. H. (2005) · Diabetologia · doi:10.1007/s00125-005-1754-y · Cited by 90 · see citing works
Influence of inflammatory cells and serum on the performance of implantable glucose sensors
Gerritsen, M., Jansen, J. A., Kros, A., Vriezema, D. M., Sommerdijk, N. A. J. M., Nolte, R. J. M., Lutterman, J. A., van Hövell, S. W. F. M., & van der Gaag, A. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200101)54:1 · Cited by 89 · see citing works
Carreau, A., Kieda, C., & Grillon, C. (2011) · Experimental Cell Research · doi:10.1016/j.yexcr.2010.08.011 · Cited by 88 · see citing works
Klueh, U., Dorsky, D. I., & Kreutzer, D. L. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.04.017 · Cited by 87 · see citing works
Weiss, R., Yegorchikov, Y., Shusterman, A., & Raz, I. (2007) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.0059 · Cited by 86 · see citing works
Kao, W. J., Zhao, Q. H., Hiltner, A., & Anderson, J. M. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280110 · Cited by 85 · see citing works
A new amperometric glucose microsensor: in vitro and short-term in vivo evaluation
Ward, W. K., Jansen, L. B., Anderson, E., Reach, G., Klein, J.-C., & Wilson, G. S. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00268-8 · Cited by 81 · see citing works
In vivo glucose monitoring: Towards ‘Sense and Act’ feedback-loop individualized medical systems
Wang, J. (2007) · Talanta · doi:10.1016/j.talanta.2007.10.023 · Cited by 81 · see citing works
Kim, T.-K., & Burgess, D. J. (2002) · Journal of Pharmacy and Pharmacology · doi:10.1211/002235702760089009 · Cited by 79 · see citing works
Quantifying the Composition of Human Skin for Glucose Sensor Development
Groenendaal, W., von Basum, G., Schmidt, K. A., Hilbers, P. A. J., & van Riel, N. A. W. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400502 · Cited by 79 · see citing works
Antibacterial properties of nitric oxide–releasing sol‐gels
Nablo, B. J., & Schoenfisch, M. H. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.20030 · Cited by 78 · see citing works
Self-citationCold- and hot-pack contrast therapy: subcutaneous and intramuscular temperature change.
Myrer, J. W., Measom, G. J., Durrant, E., & Fellingham, G. W. (1997) · Europe PMC (PubMed Central) · Cited by 76 · see citing works
Bone morphogenetic protein encapsulated with a biodegradable and biocompatible polymer
Isobe, M., Amagasa, T., Oida, S., Yamazaki, Y., Ishihara, K., & Nakabayashi, N. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199611)32:3 · Cited by 76 · see citing works
Calibration of a subcutaneous amperometric glucose sensor implanted for 7 days in diabetic patients
Choleau, C., Klein, J. C., Reach, G., Aussedat, B., Demaria-Pesce, V., Wilson, G. S., Gifford, R., & Ward, W. K. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00304-9 · Cited by 76 · see citing works
In vitro and in vivo mineralization of Nafion membrane used for implantable glucose sensors
Mercado, R. C., & Moussy, F. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00112-7 · Cited by 73 · see citing works
In vitro platelet adhesion to nonionic and ionic hydrogels with different water contents
Kulik, E. A., & Ikada, Y. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199603)30:3 · Cited by 72 · see citing works
Modulation of corneal epithelial stratification by polymer surface topography
Dalton, B. A., Evans, M. D. M., McFarland, G. A., & Steele, J. G. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19990615)45:4 · Cited by 72 · see citing works
Continuous Glucose Sensors: Continuing Questions about Clinical Accuracy
Clarke, W. L., & Kovatchev, B. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100510 · Cited by 71 · see citing works
Feasibility of Continuous Long-Term Glucose Monitoring from a Subcutaneous Glucose Sensor in Humans
Gilligan, B. C., Shults, M., Rhodes, R. K., Jacobs, P. G., Brauker, J. H., Pintar, T. J., & Updike, S. J. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504774198089 · Cited by 71 · see citing works
Macrophage behavior on surface-modified polyurethanes
Jones, J. A., Dadsetan, M., Collier, T. O., Ebert, M., Stokes, K. S., Ward, R. S., Hiltner, P. A., & Anderson, J. M. (2004) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856204323046843 · Cited by 70 · see citing works
Ju, Y. M., Yu, B., Koob, T. J., Moussy, Y., & Moussy, F. G. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31756 · Cited by 70 · see citing works
Koschwanez, H. E., Yap, F. Y., Klitzman, B., & Reichert, W. M. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31824 · Cited by 69 · see citing works
A Miniaturized Nafion-Based Glucose Sensor: in vitro and in vivo evaluation in dogs
Moussy, F., Harrison, D. J., & Rajotte, R. V. (1994) · The International Journal of Artificial Organs · doi:10.1177/039139889401700206 · Cited by 67 · see citing works
The effect of nitric oxide surface flux on the foreign body response to subcutaneous implants
Nichols, S. P., Koh, A., Brown, N. L., Rose, M. B., Sun, B., Slomberg, D. L., Riccio, D. A., Klitzman, B., & Schoenfisch, M. H. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.05.053 · Cited by 67 · see citing works
Self-citationIn vivo glucose sensing for diabetes management: progress towards non-invasive monitoring
Pickup, J., McCartney, L., Rolinski, O., & Birch, D. (1999) · BMJ · doi:10.1136/bmj.319.7220.1289 · Cited by 66 · see citing works
Synthesis and Performance of Novel Hydrogels Coatings for Implantable Glucose Sensors
Wang, C., Yu, B., Knudsen, B., Harmon, J., Moussy, F., & Moussy, Y. (2008) · Biomacromolecules · doi:10.1021/bm701102y · Cited by 63 · see citing works
Metabolic Biofouling of Glucose Sensors <i>in Vivo</i> : Role of Tissue Microhemorrhages
Klueh, U., Liu, Z., Feldman, B., Henning, T. P., Cho, B., Ouyang, T., & Kreutzer, D. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500313 · Cited by 63 · see citing works
Barman, I., Kong, C.-R., Singh, G., Dasari, R. R., & Feld, M. S. (2010) · Analytical Chemistry · doi:10.1021/ac100810e · Cited by 62 · see citing works
Linke, B., Kerner, W., Kiwit, M., Pishko, M. V., & Heller, A. (1994) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(94)80107-x · Cited by 61 · see citing works
Calibration of a subcutaneous amperometric glucose sensor
Choleau, C., Klein, J. C., Reach, G., Aussedat, B., Demaria-Pesce, V. H., Wilson, G. S., Gifford, R., & Ward, W. K. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00306-2 · Cited by 60 · see citing works
Gourzi, M., Rouane, A., Guelaz, R., Alavi, M., McHugh, M. B., Nadi, M., & Roth, P. (2004) · Journal of Medical Engineering & Technology · doi:10.1080/03091900410001720247 · Cited by 60 · see citing works
Ward, W. K., Quinn, M. J., Wood, M. D., Tiekotter, K. L., Pidikiti, S., & Gallagher, J. A. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00180-5 · Cited by 55 · see citing works
Pfützner, A., Caduff, A., Larbig, M., Schrepfer, T., & Forst, T. M. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/1520915041705839 · Cited by 55 · see citing works
Novak, M. T., Yuan, F., & Reichert, W. M. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4097-6 · Cited by 55 · see citing works
Photoinitiated Nitric Oxide-Releasing Tertiary S-Nitrosothiol-Modified Xerogels
Riccio, D. A., Coneski, P. N., Nichols, S. P., Broadnax, A. D., & Schoenfisch, M. H. (2012) · ACS Applied Materials & Interfaces · doi:10.1021/am201443r · Cited by 53 · see citing works
Self-citationErtefai, S., & Gough, D. A. (1989) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(89)90097-6 · Cited by 52 · see citing works
Ju, Y. M., Yu, B., West, L., Moussy, Y., & Moussy, F. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32400 · Cited by 52 · see citing works
Implant Healing in Experimental Animal Models of Diabetes
Le, N. N., Rose, M. B., Levinson, H., & Klitzman, B. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500315 · Cited by 52 · see citing works
Wagner, J. G., Schmidtke, D. W., Quinn, C. P., Fleming, T. F., Bernacky, B. J., & Heller, A. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.11.6379 · Cited by 51 · see citing works
Wisniewski, N., Rajamand, N., Adamsson, U., Lins, P. E., Reichert, W. M., Klitzman, B., & Ungerstedt, U. (2002) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00259.2001 · Cited by 50 · see citing works
Critical role of tissue mast cells in controlling long-term glucose sensor function in vivo
Klueh, U., Kaur, M., Qiao, Y., & Kreutzer, D. L. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.02.023 · Cited by 48 · see citing works
Flagged first, then by citations
2 of the 246 references couldn’t be matched to a known paper.
Research works printed but not linked: 14
- 2012, World Health Statistics 2012
- Wang J., 2008, Chem. Rev., 108, 814, 10.1021/cr068123a · DOI · Paper page
- Arnold M. A., 2010, In Vivo Glucose Sensing
- Vashist S. K., 2012, Anal. Chim. Acta, 750, 16, 10.1016/j.aca.2012.03.043 · DOI · Paper page
- 2012, Continuous Glucose Monitoring (CGM) Systems - Global Pipeline Analysis, Competitive Landscape and Market Forecasts to 2017
- Henning T., 2010, In Vivo Glucose Sensing
- Myrer J. W., 1997, J. Athletic Training, 32, 238
- Wilson G. S., 2009, In Vivo Glucose Sensing
- Thomé-Duret V., 1996, Diabetes Metab., 22, 174
- Helton K. L., 2011, J. Diabetes Sci. Technol., 5, 647, 10.1177/193229681100500318 · DOI · Paper page
- Sharkawy A. A., 1998, J. Biomed. Mater. Res., 40, 598, 10.1002/(sici)1097-4636(19980615)40:4 · DOI
- Marshall A. J., 2004, ACS Polym. Prepr., 45, 100
- Ratner B. D., 2009, ACS Polym. Prepr., 50, 286
- Ward W. K., 2004, Diabetes Technol. Ther., 19, 155
Cited by
Sorted by citations
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 931 · see citing works
Veiseh, O., Doloff, J. C., Ma, M., Vegas, A. J., Tam, H. H., Bader, A. R., Li, J., Langan, E., Wyckoff, J., Loo, W. S., et al. (2015) · Nature Materials · doi:10.1038/nmat4290 · Cited by 897 · see citing works
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 890 · see citing works
Design of biodegradable, implantable devices towards clinical translation
Li, C., Guo, C., Fitzpatrick, V., Ibrahim, A. G. A., Zwierstra, M. J., Hanna, P. C., Lechtig, A., Nazarian, A., Lin, S. J., & Kaplan, D. L. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0150-z · Cited by 819 · see citing works
Yetisen, A. K., Martinez‐Hurtado, J. L., Ünal, B., Khademhosseini, A., & Butt, H. (2018) · Advanced Materials · doi:10.1002/adma.201706910 · Cited by 569 · see citing works
A review of recent advances in nonenzymatic glucose sensors
Tian, K., Prestgard, M. C., & Tiwari, A. (2014) · Materials Science and Engineering C · doi:10.1016/j.msec.2014.04.013 · Cited by 547 · see citing works
Photonic crystals: emerging biosensors and their promise for point-of-care applications
Inan, H., Poyraz, M., İnci, F., Lifson, M. A., Baday, M., Cunningham, B. T., & Demirci, U. (2016) · Chemical Society Reviews · doi:10.1039/c6cs00206d · Cited by 483 · see citing works
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442 · see citing works
Carbon nanotubes as optical biomedical sensors
Kruss, S., Hilmer, A. J., Zhang, J., Reuel, N. F., Mu, B., & Strano, M. S. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.015 · Cited by 409 · see citing works
Zhang, L., Zhang, Z., Liang, R., Li, Y.-H., & Qiu, J. (2014) · Analytical Chemistry · doi:10.1021/ac500289c · Cited by 383 · see citing works
Wearable Contact Lens Biosensors for Continuous Glucose Monitoring Using Smartphones
Elsherif, M., Hassan, M. U., Yetisen, A. K., & Butt, H. (2018) · ACS Nano · doi:10.1021/acsnano.8b00829 · Cited by 371 · see citing works
Glucose‐Sensitive Hydrogel Optical Fibers Functionalized with Phenylboronic Acid
Yetisen, A. K., Jiang, N., Fallahi, A., Montelongo, Y., Ruiz‐Esparza, G. U., Tamayol, A., Zhang, Y. S., Mahmood, I., Yang, S., Kim, K. S., et al. (2017) · Advanced Materials · doi:10.1002/adma.201606380 · Cited by 310 · see citing works
Functional Fiber Materials to Smart Fiber Devices
Chen, C., Feng, J., Li, J., Guo, Y., Shi, X., & Peng, H. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00192 · Cited by 312 · see citing works
Ma, W., Jiang, Q., Yu, P., Yang, L., & Mao, L. (2013) · Analytical Chemistry · doi:10.1021/ac401576u · Cited by 307 · see citing works
Zhang, D., Chen, Q., Shi, C., Chen, M., Ma, K., Wan, J., & Liu, R. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202007226 · Cited by 304 · see citing works
Mayer, M., & Baeumner, A. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00719 · Cited by 306 · see citing works
Electrochemical Glucose Sensing: Is There Still Room for Improvement?
Nery, E. W., Kundys, M., Jeleń, P. S., & Jönsson‐Niedziółka, M. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03151 · Cited by 292 · see citing works
Functional nanocomposites and their potential applications: A review
Hassan, T., Salam, A., Khan, A., Khan, S. U., Khanzada, H., Wasim, M., Khan, M. Q., & Kim, I. S. (2021) · Journal of Polymer Research · doi:10.1007/s10965-021-02408-1 · Cited by 291 · see citing works
Doloff, J. C., Veiseh, O., Vegas, A. J., Tam, H. H., Farah, S., Ma, M., Li, J., Bader, A., Chiu, A., Sadraei, A., et al. (2017) · Nature Materials · doi:10.1038/nmat4866 · Cited by 283 · see citing works
Recent developments in nanostructure based electrochemical glucose sensors
Zaidi, S. A., & Shin, J. H. (2015) · Talanta · doi:10.1016/j.talanta.2015.11.033 · Cited by 282 · see citing works
Self-citationXie, X., Doloff, J. C., Yesilyurt, V., Sadraei, A., McGarrigle, J. J., Omami, M., Veiseh, O., Farah, S., Isa, D., Ghani, S., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0273-3 · Cited by 235 · see citing works
Zarus, G. M., Muianga, C. V., Hunter, C. M., & Pappas, R. S. (2020) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2020.144010 · Cited by 227 · see citing works
Kong, F., Gu, S.-X., Li, W., Chen, T., Xu, Q. H., & Wang, W. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.12.067 · Cited by 217 · see citing works
“This process can result in a local pH0s dropping and disrupting biosensor performance (Baylis and Till, 2009; Nichols et al., 2013).”
BackgroundPullano, S. A., Greco, M., Bianco, M. G., Foti, D., Brunetti, A., & Fiorillo, A. S. (2022) · Theranostics · doi:10.7150/thno.64035 · Cited by 210 · see citing works
“The latter, generally requires 2-3 weeks stabilization period after surgery and are larger than the subcutaneous counterparts [88].”
BackgroundMa, J., Yin, B., Wu, X., & Ye, B. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04259 · Cited by 190 · see citing works
Wu, Z., Qiao, Z., Chen, S., Fan, S., Liu, Y., Qi, J., & Lim, C. T. (2024) · Communications Materials · doi:10.1038/s43246-024-00468-6 · Cited by 197 · see citing works
Farah, S., Doloff, J. C., Müller, P., Sadraei, A., Han, H. J., Olafson, K., Vyas, K., Tam, H. H., Hollister-Lock, J., Kowalski, P. S., et al. (2019) · Nature Materials · doi:10.1038/s41563-019-0377-5 · Cited by 181 · see citing works
Ma, L., Qin, H.-H., Cheng, C., Xia, Y., He, C., Nie, C.-X., Wang, L.-R., & Zhao, C.-S. (2014) · Journal of materials chemistry. B · doi:10.1039/c3tb21388a · Cited by 157 · see citing works
Renewable‐Biomolecule‐Based Full Lithium‐Ion Batteries
Hu, P., Wang, H., Yang, Y. K., Yang, J. R., Lin, J., & Guo, L. (2016) · Advanced Materials · doi:10.1002/adma.201505917 · Cited by 177 · see citing works
Bilal, M., Nguyen, T. A., & Iqbal, H. M. N. (2020) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213475 · Cited by 158 · see citing works
Didyuk, O., Econom, N., Guardia, A., Livingston, K., & Klueh, U. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819899394 · Cited by 175 · see citing works
Recent advances in optical sensors for continuous glucose monitoring
Ahmed, I., Jiang, N., Shao, X., Elsherif, M., Alam, F., Salih, A. E., Butt, H., & Yetisen, A. K. (2022) · Sensors & Diagnostics · doi:10.1039/d1sd00030f · Cited by 136 · see citing works
Wang, H., Yi, J., Velado, D., Yu, Y., & Zhou, S. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b04744 · Cited by 137 · see citing works
Zhang, P., Zhao, X., Zhang, X. K., Lai, Y., Wang, X., Li, J., Wei, G., & Su, Z. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am500908v · Cited by 126 · see citing works
Ultrabright Polymer-Dot Transducer Enabled Wireless Glucose Monitoring via a Smartphone
Sun, K., Yang, Y., Zhou, H., Yin, S., Qin, W., Yu, J., Chiu, D. T., Yuan, Z., Zhang, X., & Wu, C. (2018) · ACS Nano · doi:10.1021/acsnano.8b02188 · Cited by 126 · see citing works
IoMT-Based Wearable Body Sensors Network Healthcare Monitoring System
Adeniyi, A. E., Ogundokun, R. O., & Awotunde, J. B. (2021) · Studies in computational intelligence · doi:10.1007/978-981-15-9897-5_6 · Cited by 123 · see citing works
Niu, X., Li, Y., Tang, J., Hu, Y., Zhao, H., & Lan, M. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.07.032 · Cited by 114 · see citing works
“Note that although the concentration of these interfering species in blood samples and other environments may be far less than that of glucose, (Nichols et al. 2013) the same level of all species is still utilized in the test to ensure the selectivity of the assembled electrochemical interface for…”
BackgroundArtificial intelligence biosensors for continuous glucose monitoring
Jin, X., Cai, A., Xu, T., & Zhang, X. (2023) · Interdisciplinary materials · doi:10.1002/idm2.12069 · Cited by 121 · see citing works
Wang, L., Zheng, J., Li, Y., Yang, S., Liu, C., Xiao, Y., Li, J., Cao, Z. Y., & Yang, R. (2014) · Analytical Chemistry · doi:10.1021/ac503653c · Cited by 109 · see citing works
Towards wearable and implantable continuous drug monitoring: A review
Bian, S., Zhu, B., Rong, G., & Sawan, M. (2020) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2020.08.001 · Cited by 105 · see citing works
Blood glucose sensors and recent advances: A review
Peng, Z., Xie, X., Tan, Q., Hu, K., Cui, J., Zhang, X., Li, W., & Feng, G. (2022) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545822300038 · Cited by 102 · see citing works
Enzymatic glucose sensor based on Au nanoparticle and plant-like ZnO film modified electrode
Tian, K., Alex, S., Siegel, G., & Tiwari, A. (2014) · Materials Science and Engineering C · doi:10.1016/j.msec.2014.10.064 · Cited by 99 · see citing works
Methylglyoxal – An emerging biomarker for diabetes mellitus diagnosis and its detection methods
Ramachandra, B. L., Vedantham, S., Krishnan, U. M., & Rayappan, J. B. B. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.03.010 · Cited by 100 · see citing works
Osmium nanozyme as peroxidase mimic with high performance and negligible interference of O 2
He, S., Yang, L. S., Balasubramanian, P., Li, S., Peng, H., Kuang, Y., Deng, H., & Chen, W. (2020) · Journal of Materials Chemistry A · doi:10.1039/d0ta09247a · Cited by 96 · see citing works
Silk‐Inspired β‐Peptide Materials Resist Fouling and the Foreign‐Body Response
Zhang, D., Chen, Q., Zhang, W., Liu, H., Wan, J., Qian, Y., Li, B., Tang, S., Liu, Y., Chen, S., et al. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.202000416 · Cited by 95 · see citing works
Lee, S. J., Yoon, H. S., Xuan, X., Park, J. Y., Paik, S., & Allen, M. G. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.08.013 · Cited by 94 · see citing works
Hu, Y., Liang, B., Lü, F., Ma, G., Yang, G. Y., Zhu, Q. Y., Chen, S., & Ye, X. (2016) · Langmuir · doi:10.1021/acs.langmuir.6b03016 · Cited by 93 · see citing works
Review of present method of glucose from human blood and body fluids assessment
Fiedorova, K., Augustýnek, M., Kubíček, J., Kudrna, P., & Bibbo, D. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114348 · Cited by 93 · see citing works
Wearable strain sensors: state-of-the-art and future applications
Yadav, A. K., Yadav, N., Wu, Y., Ramakrishna, S., & Zheng, H. Y. (2023) · Materials Advances · doi:10.1039/d2ma00818a · Cited by 85 · see citing works
In Vivo Chemical Sensors: Role of Biocompatibility on Performance and Utility
Soto, R. J., Hall, J. R., Brown, M. D., Taylor, J. B., & Schoenfisch, M. H. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04251 · Cited by 85 · see citing works
Self-citationImplantable Nanosensors: Toward Continuous Physiologic Monitoring
Ruckh, T. T., & Clark, H. A. (2013) · Analytical Chemistry · doi:10.1021/ac402688k · Cited by 84 · see citing works
Li, J., Li, Y., Shahzad, S. A., Chen, J., Yang, C., Wang, Y., Yang, M., & Yu, C. (2015) · Chemical Communications · doi:10.1039/c4cc10381e · Cited by 83 · see citing works
A smart hydrogel system for visual detection of glucose
Wu, M., Zhang, Y., Liu, Q., Huang, H., Wang, X., Shi, Z., Li, Y., Liu, S., Xue, L., & Lei, Y. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111547 · Cited by 83 · see citing works
Chen, D., Pang, D., Zhang, S., Song, H., Zhu, W., & Zhu, J. (2019) · Electrochimica Acta · doi:10.1016/j.electacta.2019.135326 · Cited by 83 · see citing works
Modulating the foreign body response of implants for diabetes treatment
Kharbikar, B. N., Chendke, G. S., & Desai, T. A. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.01.011 · Cited by 83 · see citing works
Technological Advances of Wearable Device for Continuous Monitoring of In Vivo Glucose
Huang, X., Yao, C., Huang, S., Zheng, S., Liu, Z., Liu, J., Wang, J., Chen, H., & Xie, X. (2024) · ACS Sensors · doi:10.1021/acssensors.3c01947 · Cited by 81 · see citing works
Xiong, Y., Zhang, Y., Rong, P., Yang, J. A., Wang, W., & Liu, D. (2015) · Nanoscale · doi:10.1039/c5nr03758a · Cited by 81 · see citing works
Organs-on-chip monitoring: sensors and other strategies
Kilic, T., Navaee, F., Stradolini, F., Renaud, P., & Carrara, S. (2018) · Microphysiological Systems · doi:10.21037/mps.2018.01.01 · Cited by 96 · see citing works
“For development of such sensors, fluorescent dyes, quantum dots, crystalline colloidal arrays, plasmonic nanoantennas are incorporated (106).”
BackgroundIlango, P. R., Prasanna, K., Do, S. J., Jo, Y. N., & Lee, C. W. (2016) · Scientific Reports · doi:10.1038/srep29826 · Cited by 76 · see citing works
Nanopatterned bulk metallic glass-based biomaterials modulate macrophage polarization
Shayan, M., Padmanabhan, J., Morris, A. H., Cheung, B. H., Smith, R., Schroers, J., & Kyriakides, T. R. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.05.051 · Cited by 75 · see citing works
Wu, H., Lee, C.-J., Wang, H.-F., Hu, Y., Young, M., Han, Y., Xu, F., Cong, H., & Cheng, G. (2018) · Chemical Science · doi:10.1039/c7sc05104b · Cited by 74 · see citing works
Recent advances in carbon nanotubes-based biocatalysts and their applications
Kumari, A., Rajeev, R., Benny, L., Sudhakar, Y. N., Varghese, A., & Hegde, G. (2021) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2021.102542 · Cited by 71 · see citing works
A novel multicomponent redox polymer nanobead based high performance non-enzymatic glucose sensor
Gopalan, A., Nallal, M., Komathi, S., & Lee, K.-P. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.079 · Cited by 68 · see citing works
Liu, W., Wang, N., Lin, X., Ma, Y., & Lin, J. (2014) · Analytical Chemistry · doi:10.1021/ac501678q · Cited by 68 · see citing works
Hydrogel‐based composites: Unlimited platforms for biosensors and diagnostics
Wang, Z., Liu, Y., Wang, Z., Huang, X. B., & Huang, W. (2021) · Open Research (University of Surrey) · doi:10.1002/viw.20200165 · Cited by 68 · see citing works
Ophthalmic Sensors and Drug Delivery
Savariraj, A. D., Salih, A. E., Alam, F., Elsherif, M., AlQattan, B., Khan, A. A., Yetisen, A. K., & Butt, H. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00370 · Cited by 68 · see citing works
Gupta, S., & Tai, N. (2023) · Journal of the Taiwan Institute of Chemical Engineers · doi:10.1016/j.jtice.2023.104957 · Cited by 69 · see citing works
Magnetic Fe3O4-Reduced Graphene Oxide Nanocomposites-Based Electrochemical Biosensing
Yu, L., Wu, H., Wu, B., Wang, Z., Cao, H., Fu, C., & Jia, N. (2014) · Nano-Micro Letters · doi:10.1007/bf03353790 · Cited by 68 · see citing works
Optical sensors for continuous glucose monitoring
Yu, Z., Jiang, N., Kazarian, S. G., Taşoğlu, S., & Yetisen, A. K. (2021) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/abe6f8 · Cited by 67 · see citing works
“The electrochemical sensors could easily achieve continuous monitoring by transmitting the real-time data to wireless electronics, while colorimetric sensors could be directly read by the naked eye without the aid of additional equipment [28].”
InfluentialKore, R., Srivastava, R., & Satpati, B. (2014) · Chemistry - A European Journal · doi:10.1002/chem.201402665 · Cited by 66 · see citing works
Implantable application of polymer‐based biosensors
Mei, X., Ye, D., Zhang, F., & Di, C. (2021) · Journal of Polymer Science · doi:10.1002/pol.20210543 · Cited by 64 · see citing works
Immunomodulation Effect of Biomaterials on Bone Formation
Zhao, T., Chu, Z., Ma, J., & Ouyang, L. (2022) · Journal of Functional Biomaterials · doi:10.3390/jfb13030103 · Cited by 64 · see citing works
Bioresponsive controlled release from mesoporous silica nanocontainers with glucometer readout
Hou, L., Zhu, C., Wu, X., Chen, G., & Tang, D. (2013) · Chemical Communications · doi:10.1039/c3cc48453j · Cited by 65 · see citing works
Zhou, Z., Xu, L., Wu, S., & Su, B. (2014) · The Analyst · doi:10.1039/c4an00687a · Cited by 65 · see citing works
Hao, T., Xiao, W., Nie, Y., Xu, Y., Lu, K. J., Yan, Y., & Zhou, Z. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.02.002 · Cited by 64 · see citing works
Du, Q., Wu, P., Dramou, P., Chen, R., & He, H. (2018) · New Journal of Chemistry · doi:10.1039/c8nj05318a · Cited by 64 · see citing works
Glucose Concentration Measurement in Human Blood Plasma Solutions with Microwave Sensors
Juan, C. G., Bronchalo, E., Potelon, B., Quendo, C., & Sabater-Navarro, J. M. (2019) · Sensors · doi:10.3390/s19173779 · Cited by 63 · see citing works
Thermal Detection of Glucose in Urine Using a Molecularly Imprinted Polymer as a Recognition Element
Caldara, M., Lowdon, J. W., Rogosic, R., Arreguin-Campos, R., Jiménez-Monroy, K. L., Heidt, B., Tschulik, K., Cleij, T. J., Diliën, H., Eersels, K., et al. (2021) · ACS Sensors · doi:10.1021/acssensors.1c02223 · Cited by 63 · see citing works
Sui, Y., Cui, Y. H., Meng, X., & Zhou, Q. (2021) · Journal of Applied Polymer Science · doi:10.1002/app.52096 · Cited by 62 · see citing works
Qureshi, A., & Niazi, J. H. (2023) · Materials Horizons · doi:10.1039/d2mh01517j · Cited by 62 · see citing works
Koh, A., Lu, Y., & Schoenfisch, M. H. (2013) · Analytical Chemistry · doi:10.1021/ac402312b · Cited by 61 · see citing works
Self-citationPlasma assisted surface treatments of biomaterials
Minati, L., Migliaresi, C., Lunelli, L., Viero, G., Serra, M. D., & Speranza, G. (2017) · Biophysical Chemistry · doi:10.1016/j.bpc.2017.07.003 · Cited by 62 · see citing works
Continuous Glucose Monitoring Enabled by Fluorescent Nanodiamond Boronic Hydrogel
Zhang, J., Zheng, Y., Lee, J., Hoover, A., King, S. A., Chen, L., Zhao, J., Lin, Q., Yu, C., Zhu, L., et al. (2023) · Advanced Science · doi:10.1002/advs.202203943 · Cited by 63 · see citing works
Xiao, Y., Xu, L., & Qi, L. (2017) · Talanta · doi:10.1016/j.talanta.2017.01.019 · Cited by 61 · see citing works
Microneedle-based glucose monitoring: a review from sampling methods to wearable biosensors
Wang, Y., Wu, Y., & Lei, Y. (2023) · Biomaterials Science · doi:10.1039/d3bm00409k · Cited by 60 · see citing works
“9,114 The first generation of enzymatic glucose sensors immobilized the enzyme (such as GOx) on the electrode surfaces, upon which oxygen was used as oxidation mediator, 115 and the consumption of oxygen or the generation of peroxide was measured during the enzymatic reaction (Fig.”
Glucose‐Sensing Photonic Nanochain Probes with Color Change in Seconds
Cai, J., Luo, W. J., Pan, J., Li, G., Pu, Y., Si, L., Shi, G., Shao, Y., Ma, H., & Guan, J. (2022) · Advanced Science · doi:10.1002/advs.202105239 · Cited by 58 · see citing works
Biosensors for Blood Glucose and Diabetes Diagnosis: Evolution, Construction, and Current Status
Martinková, P., & Pohanka, M. (2015) · Analytical Letters · doi:10.1080/00032719.2015.1043661 · Cited by 60 · see citing works
“O2 þ 2Hþ þ 2e ð3Þ The first device allowing glucose measurement in whole blood was constructed in 1975 and was based on electrodes with immobilized glucose oxidase and an electrochemical transducer (Nichols et al. 2013).”
MethodZhou, H., Cheng, C., Qin, H., Ma, L., He, C. H., Nie, S., Zhang, X., Fu, Q., & Zhao, C. (2014) · Polymer Chemistry · doi:10.1039/c4py00136b · Cited by 59 · see citing works
MoS2 as connector inspired high electrocatalytic performance of NiCo2O4 nanoplates towards glucose
Wang, S., Zhang, S., Liu, M., Song, H., Gao, J., & Qian, Y. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.08.011 · Cited by 58 · see citing works
PUVA therapy for drug-resistant graft-versus-host disease.
Atkinson, K., Weller, P., Ryman, W. J., & Biggs, J. C. (1986) · PubMed · Cited by 58 · see citing works
All‐Polymer Fiber Organic Electrochemical Transistor for Chronic Chemical Detection in the Brain
Feng, J., Fang, Y., Wang, C., Chen, C., Tang, C., Guo, Y., Wang, L., Yang, Y., Zhang, K., Wang, J., et al. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202214945 · Cited by 57 · see citing works
Subcutaneously implantable electromagnetic biosensor system for continuous glucose monitoring
Kim, S., Malik, J., Seo, J. M., Cho, Y. M., & Bien, F. D. (2022) · Scientific Reports · doi:10.1038/s41598-022-22128-w · Cited by 57 · see citing works
Heyser, C. A., Schrebler, R., & Grez, P. (2018) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2018.10.054 · Cited by 55 · see citing works
Role of dendritic cells in the host response to biomaterials and their signaling pathways
Zhu, F., Tong, Y., Sheng, Z.-Y., & Yao, Y.-M. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.05.038 · Cited by 56 · see citing works
Activation of Macrophages in Response to Biomaterials
Rayahin, J., & Gemeinhart, R. A. (2017) · Results and problems in cell differentiation · doi:10.1007/978-3-319-54090-0_13 · Cited by 55 · see citing works
MOMSense: Metal-Oxide-Metal Elementary Glucose Sensor
Abunahla, H., Mohammad, B. S., Alazzam, A., Jaoudé, M. A., Al‐Qutayri, M., Hadi, S. A., & Al-Sarawi, S. F. (2019) · Scientific Reports · doi:10.1038/s41598-019-41892-w · Cited by 54 · see citing works
Glucose Sensing Using Functionalized Amorphous In–Ga–Zn–O Field-Effect Transistors
Du, X., Li, Y., Motley, J. R., Stickle, W. F., & Herman, G. S. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b12058 · Cited by 53 · see citing works
Polymeric Micellar Structures for Biosensor Technology
Shukla, S. K., Govender, P. P., & Tiwari, A. (2016) · Advances in biomembranes and lipid self-assembly · doi:10.1016/bs.abl.2016.04.005 · Cited by 53 · see citing works
Li, Y., Luo, S., Gui, Y., Wang, X., Tian, Z., & Yu, H. (2023) · Biosensors · doi:10.3390/bios13020287 · Cited by 50 · see citing works
“Continuous glucose monitoring (CGM) is a feasible method for real-time and dynamic detection of glucose concentration by implanting glucose sensors into the subcutaneous tissue, which can be used in combination with an insulin injection pump to help people with diabetes with treatment [4].”
MethodVallejo-Heligon, S. G., Brown, N. L., Reichert, W. M., & Klitzman, B. M. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.10.045 · Cited by 50 · see citing works
“The commercial success of implantable glucose sensors has been hindered by their premature failure that has been attributed largely to the deleterious tissue effects such as biofouling, the immune response, and fibrous encapsulation [7, 9, 10, 12].”
BackgroundInfluential
- Authors
- Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H.
- Affiliations
- University of North Carolina at Chapel Hill (US)
- Kwangwoon University (KR)
- Corresponding author
- Schoenfisch, Mark H.
- Venue
- Chemical Reviews
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-02-07
- Volume
- 113
- Issue
- 4
- Pages
- 2528-2549
- ISSN
- 0009-2665 (ISSN-L)
- 1520-6890
- PMC
- PMC3624030
- OpenAlex
- W1993893772
- Semantic Scholar
- 15d86c3915bf4d8443f91beee6a62f80dcdc9ac4
- Cited by
- 347
- References
- 246
- Citations by year
- 2026: 20 · 2025: 25 · 2024: 26 · 2023: 26 · 2022: 28 · 2021: 31 · 2020: 23 · 2019: 23 · 2018: 31 · 2017: 20 · 2016: 37 · 2015: 21 · 2014: 20 · 2013: 14
- FWCI
- 2.55
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Chemical Reviews (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of Biomedical Imaging and Bioengineering (EB 000708, R01EB000708)
- Topics
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Keywords
- biomaterials, continuous glucose monitoring, biomedical implants, diabetes mellitus, biocompatibility, glucose sensor, tissue response to implants, inflammation, diabetes complications, diabetes management, diabetes prevention
- MeSH terms
- Animals, Biocompatible Materials, Blood Glucose, Diabetes Mellitus, Disease Models, Animal, Humans, Polymers, Blood Glucose Self-Monitoring, Biosensing Techniques, Porosity, Elastic Modulus, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-06.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-06.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review