Use of electric cell–substrate impedance sensing to assess in vitro cytotoxicity
Open accessThe DOI matches its Crossref record.
Abstract
In vitro assessment of cytotoxicity based on electrochemical impedance spectroscopy (EIS) needs more quantitative methods to analyze the alteration of cell morphology and motility, and hence the potential risk to human health. Here, we applied electric cell-substrate impedance sensing (ECIS) to evaluate dose-dependent responses of human umbilical vein endothelial cells exposed to cytochalasin B. To detect subtle changes in cell morphology, the frequency-dependent impedance data of the cell monolayer were measured and analyzed with a theoretical cell-electrode model. To detect the alternation of cell micromotion in response to cytochalasin B challenge, time-series impedance fluctuations of cell-covered electrodes were monitored and the values of power spectrum, variance, and variance of the increments were calculated to verify the difference. While a dose-dependent relationship was generally observed from the overall resistance of the cell monolayer, the analysis of frequency-dependent impedance and impedance fluctuations distinguished cytochalasin B levels as low as 0.1 μM. Our results show that cytochalasin B causes a decrease of junctional resistance between cells, an increase of membrane capacitance, and the reduction in micromotion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Maoz, B. M., Herland, A., Henry, O. Y. F., Leineweber, W. D., Yadid, M., Doyle, J., Mannix, R., Kujala, V. J., FitzGerald, E. A., Parker, K. K., et al. (2017) · Lab on a Chip · doi:10.1039/c7lc00412e · Cited by 266
Xiao, B., Han, M. K., Viennois, E., Wang, L., Zhang, M., Si, X., & Merlin, D. (2015) · Nanoscale · doi:10.1039/c5nr04831a · Cited by 152
Koo, Y., & Yun, Y. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2016.06.094 · Cited by 37
Metadata
- Authors
- Opp, D., Wafula, B., Lim, J., Huang, E., Lo, J.-C., & Lo, C.-M.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2009-04
- Volume
- 24
- Issue
- 8
- Pages
- 2625-2629
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2050662100
- Cited by
- 125
- References
- 0
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of electric cell–substrate impedance sensing to assess in vitro cytotoxicity. https://app.cochat.ai/papers/10.1016/j.bios.2009.01.015
- The paper
- Opp, D., Wafula, B., Lim, J., Huang, E., Lo, J.-C., & Lo, C.-M. (2009). Use of electric cell–substrate impedance sensing to assess in vitro cytotoxicity. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2009.01.015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.