Enhancing the longevity of microparticle-based glucose sensors towards 1 month continuous operation

Open access
Singh, Saurabh, McShane, Mike·2010·Biosensors and Bioelectronics

Abstract

Luminescent microspheres encapsulating glucose oxidase have recently been reported as potential implantable sensors, but the operational lifetime of these systems has been limited by enzyme degradation. We report here that the longevity of these enzymatic microparticle-based sensors has been extended by the coimmobilization of glucose oxidase (GOx) and catalase (CAT) into the sensor matrix. A mathematical model was used to compare the response and longevity of the sensors with and without catalase. To experimentally test the longevity, sensors were continuously operated under normoglycemic dermal substrate concentrations and physiological conditions (5.5 mM glucose and 140 microM O(2), 37 degrees C and pH 7.4). The sensors incorporating CAT were experimentally shown to be approximately 5 times more stable than those without CAT; nevertheless, the response of sensors with CAT still changed by approximately 20%, when operated continuously for 7 days. The experimentally determined trends obtained for the variation in sensor response due to enzyme deactivation were in close agreement with modeling predictions, which also revealed a significant apparent loss in enzyme activity upon immobilization. It was further predicted via modeling that by incorporating 0.1 mM each of active GOx and CAT, the sensors will exhibit less than 2% variation in response over 1 month of continuous operation.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2009.09.026

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Singh, S., & McShane, M.
Affiliations
Texas A&M University (US)
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2010-01
Volume
25
Issue
5
Pages
1075-1081
ISSN
0956-5663 (ISSN-L)
OpenAlex
W1964611095
Cited by
35
References
22
Citations by year
2025: 1 · 2024: 2 · 2023: 2 · 2021: 2 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 3 · 2013: 4 · 2012: 5
FWCI
4.23
Type
journal article
Language
en
Open access
Locations
  • Biosensors and Bioelectronics (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Institutes of Health
  • National Institute of Biomedical Imaging and Bioengineering (R01EB000739)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Enzyme Catalysis and Immobilization
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
Keywords
glucose sensor, glucose oxidase, catalase, enzyme co-immobilization, enzyme degradation, implantable sensors, continuous glucose monitoring, oxygen scavenging
MeSH terms
Catalase, Computer Simulation, Equipment Design, Glucose, Glucose Oxidase, Luminescent Measurements, Microspheres, Models, Chemical, Sensitivity and Specificity, Reproducibility of Results, Biosensing Techniques, Computer-Aided Design, Equipment Failure Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review