The interplay between pH sensitivity and label-free protein detection in immunologically modified nano-scaled field-effect transistor
Abstract
We present experimental results in order to establish a correlation between pH sensitivity of immunologically modified nano-scaled field-effect transistor (NS-ImmunoFET) with their sensing capacity for label-free detection. The NS-ImmunoFETs are fabricated from silicon-on-insulator (SOI) wafers and are fully-depleted with thickness of ~20 nm. The data shows that higher sensitivity to pH entails enhanced sensitivity to analyte detection. This suggests that the mechanism of analyte detection as pure electrostatic perturbation induced by antibody-analyte interaction is over simplified. The fundamental assumption, in existing models for field-effect sensing mechanism assumes that the analyte molecules do not directly interact with the surface but rather stand 'deep' in the solution and away from the dielectric surface. Recent studies clearly provide contradicting evidence demonstrating that antibodies lie down flat on the surface. These observations led us to propose that the proteins that cover the gate area intimately interact with active sites on the surface thus forming a network of interacting sites. Since sensitivity to pH is directly correlated with the amount of amphoteric sites, we witness a direct correlation between sensitivity to pH and analyte detection. The highest and lowest threshold voltage shift for a label-free and specific detection of 6.5 nM IgG were 40 mV and 2.3 mV for NS-ImmunoFETs with pH sensitivity of 35 mV/decade and 15 mV/decade, respectively. Finally, physical modeling of the NS-ImmunoFET is presented and charge of a single IgG protein at pH 6 is calculated. The obtained value is consistent with charge of IgG protein cited in literature.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Using the above assumptions, the shift in front threshold voltage is given by ΔV_Tf = -Q_cTnI/C_cTnI = -Q*_cTnI t_cTnI / ε_cTnI.
“It was previously demonstrated À that using the above assumptions, the shift in front threshold voltage (DV Tf ) is 37 :”
From Specific and label-free femtomolar biomarker detection with an electrostatically formed nanowire biosensor (2013) · cites this paper as [37]
Cites
van Hal, R. E. G., Eijkel, J. C. T., & Bergveld, P. (1995) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(95)85043-0 · Cited by 311 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Shalev, G., Landman, G., Amit, I., Rosenwaks, Y., & Levy, I. (2013) · NPG Asia Materials · doi:10.1038/am.2012.75 · Cited by 61 · see citing works
Self-citation
- Authors
- Shalev, G., Rosenwaks, Y., & Levy, I.
- Affiliations
- Tel Aviv University (IL)
- Soroka Medical Center (IL)
- Corresponding author
- Rosenwaks, Yossi
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2012-01
- Volume
- 31
- Issue
- 1
- Pages
- 510-515
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2006444815
- Cited by
- 28
- References
- 1
- Citations by year
- 2025: 3 · 2024: 2 · 2023: 2 · 2022: 2 · 2021: 1 · 2020: 1 · 2019: 2 · 2018: 3 · 2017: 4 · 2016: 1 · 2014: 4 · 2013: 3
- FWCI
- 1.69
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Biosensors and Bioelectronics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Nanowire Synthesis and Applications
- Keywords
- immunosensor, label-free protein detection, pH sensitivity, IgG detection, threshold voltage shift, protein surface charge, silicon-on-insulator, fully depleted SOI
- MeSH terms
- Amplifiers, Electronic, Conductometry, Equipment Design, Hydrogen-Ion Concentration, Immunoglobulin G, Immunoassay, Sensitivity and Specificity, Transistors, Electronic, Reproducibility of Results, Biosensing Techniques, Equipment Failure Analysis, Nanotechnology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review