Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 368

The DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.

Brief review of monitoring methods for loop-mediated isothermal amplification (LAMP)

Open access
Zhang, Xuzhi, Lowe, Stuart B., Gooding, John Justin·2014·Biosensors and Bioelectronics

Abstract

The loop-mediated isothermal amplification (LAMP) technique has the potential to revolutionize molecular biology because it allows DNA amplification under isothermal conditions and is highly compatible with point-of-care analysis. To achieve efficient genetic analysis of samples, the method of real-time or endpoint determination selected to monitor the biochemical reaction is of great importance. In this paper we briefly review progress in the development of monitoring methods for LAMP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2014.05.039

Cites

60 of 60 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 60 references

Cited by

See all 368

Metadata

Authors
Zhang, X., Lowe, S. B., & Gooding, J. J.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2014-11
Volume
61
Pages
491-499
ISSN
0956-5663 (ISSN-L)
OpenAlex
W2022800117
Cited by
368
References
60
FWCI
9.27
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Brief review of monitoring methods for loop-mediated isothermal amplification (LAMP). https://app.cochat.ai/papers/10.1016/j.bios.2014.05.039
The paper
Zhang, X., Lowe, S. B., & Gooding, J. J. (2014). Brief review of monitoring methods for loop-mediated isothermal amplification (LAMP). Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2014.05.039

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.