The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
3D-printed supercapacitor-powered electrochemiluminescent protein immunoarray
Open accessAbstract
Herein we report a low cost, sensitive, supercapacitor-powered electrochemiluminescent (ECL) protein immunoarray fabricated by an inexpensive 3-dimensional (3D) printer. The immunosensor detects three cancer biomarker proteins in serum within 35 min. The 3D-printed device employs hand screen printed carbon sensors with gravity flow for sample/reagent delivery and washing. Prostate cancer biomarker proteins, prostate specific antigen (PSA), prostate specific membrane antigen (PSMA) and platelet factor-4 (PF-4) in serum were captured on the antibody-coated carbon sensors followed by delivery of detection-antibody-coated Ru(bpy)32+ (RuBPY)-doped silica nanoparticles in a sandwich immunoassay. ECL light was initiated from RuBPY in the silica nanoparticles by electrochemical oxidation with tripropylamine (TPrA) co-reactant using supercapacitor power and ECL was captured with a CCD camera. The supercapacitor was rapidly photo-recharged between assays using an inexpensive solar cell. Detection limits were 300–500 fg mL−1 for the 3 proteins in undiluted calf serum. Assays of 6 prostate cancer patient serum samples gave good correlation with conventional single protein ELISAs. This technology could provide sensitive onsite cancer diagnostic tests in resource-limited settings with the need for only moderate-level training.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Where do batteries end and supercapacitors begin?
Simon, P., Gogotsi, Y., & Dunn, B. (2014) · Science · doi:10.1126/science.1249625 · Cited by 5,634
Evaluation of 3D Printing and Its Potential Impact on Biotechnology and the Chemical Sciences
Gross, B. C., Erkal, J. L., Lockwood, S. Y., Chen, C., & Spence, D. M. (2014) · Analytical Chemistry · doi:10.1021/ac403397r · Cited by 1,746
Cited by
The upcoming 3D-printing revolution in microfluidics
Bhattacharjee, N., Urrios, A., Kang, S., & Folch, A. (2016) · Lab on a Chip · doi:10.1039/c6lc00163g · Cited by 1,123
3D printed microfluidic devices: enablers and barriers
Waheed, S., Cabot, J. M., Macdonald, N. P., Lewis, T., Guijt, R. M., Paull, B., & Breadmore, M. C. (2016) · Lab on a Chip · doi:10.1039/c6lc00284f · Cited by 1,039
SERS-Activated Platforms for Immunoassay: Probes, Encoding Methods, and Applications
Wang, Z., Zong, S., Wu, L., Zhu, D., & Cui, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00027 · Cited by 614
Gale, B. K., Jafek, A. R., Lambert, C. J., Goenner, B. L., Moghimifam, H., Nze, U. C., & Kamarapu, S. K. (2018) · Inventions · doi:10.3390/inventions3030060 · Cited by 511
Recent Developments in Fused Deposition Modeling-Based 3D Printing of Polymers and Their Composites
Rahim, T. N. A. T., Abdullah, A. M., & Md Akil, H. (2019) · Polymer Reviews · doi:10.1080/15583724.2019.1597883 · Cited by 452
Metadata
- Authors
- Kadimisetty, K., Mosa, I. M., Malla, S., Satterwhite-Warden, J. E., Kuhns, T. M., Faria, R. C., Lee, N. H., & Rusling, J. F.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2016-03
- Volume
- 77
- Pages
- 188-193
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W1963428971
- Cited by
- 172
- References
- 2
- FWCI
- 7.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3D-printed supercapacitor-powered electrochemiluminescent protein immunoarray. https://app.cochat.ai/papers/10.1016/j.bios.2015.09.017
- The paper
- Kadimisetty, K., Mosa, I. M., Malla, S., Satterwhite-Warden, J. E., Kuhns, T. M., Faria, R. C., Lee, N. H., & Rusling, J. F. (2016). 3D-printed supercapacitor-powered electrochemiluminescent protein immunoarray. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2015.09.017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.