Size-controlled preparation of peroxidase-like graphene-gold nanoparticle hybrids for the visible detection of norovirus-like particles
Open accessAbstract
A hybrid structure of graphene-gold nanoparticles (Grp-Au NPs) was designed as a new nanoprobe for colorimetric immunoassays. This hybrid structure was prepared using chloroauric acid, sodium formate and Grp flakes at room temperature. Au NPs attached strongly onto the Grp surface, and their size was controlled by varying the sodium formate concentration. The Raman intensity of the Grp-Au NP hybrids was significantly enhanced at 1567cm-1 and 2730cm-1 compared with those of pristine Grp because of the electronic interaction between Au NPs and Grp. The Grp-Au NPs with a hybrid structure catalyzed the oxidation of the peroxidase substrate 3,3,5,5-tetramethylbenzidine (TMB) with H2O2, developing a blue color in aqueous solution. This catalytic activity was utilized to detect norovirus-like particles (NoV-LPs) in human serum. The enhanced colorimetric response was monitored using Ab-conjugated-Grp-Au NPs and found to depend on the NoV-LP concentration, exhibiting a linear response from 100pg/mL to 10μg/mL. The limit of detection (LOD) of this proposed method was 92.7pg/mL, 112 times lower than that of a conventional enzyme-linked immunosorbent assay (ELISA). The sensitivity of this test was also 41 times greater than that of a commercial diagnostic kit. The selectivity of the Grp-Au NPs was tested with other viruses, and no color changes were observed. Therefore, the proposed system will facilitate the utilization of the intrinsic peroxidase-like activity of Grp-Au NPs in medical diagnostics. We believe that the engineered catalytic Grp-Au NP hybrids could find potential applications in the future development of biocatalysts and bioassays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intrinsic peroxidase-like activity of ferromagnetic nanoparticles
Gao, L., Zhuang, J., Nie, L., Zhang, J., Zhang, Y., Gu, N., Wang, T., Feng, J., Yang, D., Perrett, S., et al. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.260 · Cited by 7,483
Cited by
Nanomaterials with enzyme-like characteristics (nanozymes): next-generation artificial enzymes (II)
Wu, J., Wang, X., Wang, Q., Lou, Z., Li, S., Zhu, Y., Qin, L., & Wei, H. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00457a · Cited by 4,108
Structure and activity of nanozymes: Inspirations for de novo design of nanozymes
Wang, Z., Zhang, R., Yan, X., & Fan, K. (2020) · Materials Today · doi:10.1016/j.mattod.2020.08.020 · Cited by 898
Carbon Nanozymes: Enzymatic Properties, Catalytic Mechanism, and Applications
Sun, H., Zhou, Y., Ren, J., & Qu, X. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201712469 · Cited by 648
Multienzyme‐Like Nanozymes: Regulation, Rational Design, and Application
Sheng, J., Wu, Y., Ding, H., Feng, K., Shen, Y., Zhang, Y., & Gu, N. (2024) · Advanced Materials · doi:10.1002/adma.202211210 · Cited by 475
Ganganboina, A. B., Chowdhury, A. D., Khoris, I. M., Nasrin, F., Takemura, K., Hara, T., Abe, F., Suzuki, T., & Park, E. Y. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112169 · Cited by 68
Self-citation
Metadata
- Authors
- Ahmed, S. R., Takemeura, K., Li, T.-C., Kitamoto, N., Tanaka, T., Suzuki, T., & Park, E. Y.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2017-01
- Volume
- 87
- Pages
- 558-565
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2517418764
- Cited by
- 159
- References
- 1
- FWCI
- 6.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.