The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
Strategies of molecular imprinting-based fluorescence sensors for chemical and biological analysis
Open accessAbstract
One pressing concern today is to construct sensors that can withstand various disturbances for highly selective and sensitive detecting trace analytes in complicated samples. Molecularly imprinted polymers (MIPs) with tailor-made binding sites are preferred to be recognition elements in sensors for effective targets detection, and fluorescence measurement assists in highly sensitive detection and user-friendly control. Accordingly, molecular imprinting-based fluorescence sensors (MI-FL sensors) have attracted great research interest in many fields such as chemical and biological analysis. Herein, we comprehensively review the recent advances in MI-FL sensors construction and applications, giving insights on sensing principles and signal transduction mechanisms, focusing on general construction strategies for intrinsically fluorescent or nonfluorescent analytes and improvement strategies in sensing performance, particularly in sensitivity. Construction strategies are well overviewed, mainly including the traditional indirect methods of competitive binding against pre-bound fluorescent indicators, employment of fluorescent functional monomers and embedding of fluorescence substances, and novel rational designs of hierarchical architecture (core-shell/hollow and mesoporous structures), post-imprinting modification, and ratiometric fluorescence detection. Furthermore, MI-FL sensor based microdevices are discussed, involving micromotors, test strips and microfluidics, which are more portable for rapid point-of-care detection and in-field diagnosing. Finally, the current challenges and future perspectives of MI-FL sensors are proposed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electric Field Effect in Atomically Thin Carbon Films
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Zhang, Y., Dubonos, S. V., Grigorieva, I. V., & Firsov, A. A. (2004) · Science · doi:10.1126/science.1102896 · Cited by 66,834
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Zwischenmolekulare Energiewanderung und Fluoreszenz
Förster, T. (1948) · Annalen der Physik · doi:10.1002/andp.19484370105 · Cited by 8,285
Electrophoretic Analysis and Purification of Fluorescent Single-Walled Carbon Nanotube Fragments
Xu, X., Ray, R., Gu, Y., Ploehn, H. J., Gearheart, L., Raker, K., & Scrivens, W. A. (2004) · Journal of the American Chemical Society · doi:10.1021/ja040082h · Cited by 5,323
Upconversion and Anti-Stokes Processes with f and d Ions in Solids
Auzel, F. (2004) · Chemical Reviews · doi:10.1021/cr020357g · Cited by 5,098
Carbon quantum dots and their applications
Lim, S. Y., Shen, W., & Gao, Z. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00269e · Cited by 4,976
Fluorogenic and Chromogenic Chemosensors and Reagents for Anions
Martínez-Máñez, R., & Sancenón, F. (2003) · Chemical Reviews · doi:10.1021/cr010421e · Cited by 3,076
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
Carbon quantum dots: synthesis, properties and applications
Wang, Y., & Hu, A. (2014) · Journal of Materials Chemistry C · doi:10.1039/c4tc00988f · Cited by 2,597
Molecular imprinting: perspectives and applications
Chen, L., Wang, X., Lu, W., Wu, X., & Li, J. (2016) · Chemical Society Reviews · doi:10.1039/c6cs00061d · Cited by 2,460
Self-citation
Cited by
Strategies of molecular imprinting-based solid-phase extraction prior to chromatographic analysis
Arabi, M., Ostovan, A., Bagheri, A. R., Guo, X., Wang, L., Li, J., Wang, X., Li, B., & Chen, L. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.115923 · Cited by 463
Self-citationArabi, M., Ostovan, A., Zhang, Z., Wang, Y., Mei, R., Fu, L., Wang, X., Ma, J., & Chen, L. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112825 · Cited by 404
Self-citation
Metadata
- Authors
- Yang, Q., Li, J., Wang, X., Peng, H., Xiong, H., & Chen, L.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2018-07
- Volume
- 112
- Pages
- 54-71
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2802823174
- Cited by
- 369
- References
- 64
- FWCI
- 24.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.