The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Origami multiple paper-based electrochemical biosensors for pesticide detection
Abstract
Herein, we propose the first three-dimensional origami paper-based device for the detection of several classes of pesticides by combining different enzyme-inhibition biosensors. This device was developed by integrating two different office paper-based screen-printed electrodes and multiple filter paper-based pads to load enzymes and enzymatic substrates. The versatile analysis of different pesticides was carried by folding and unfolding the filter paper-based structure, without any addition of reagents and any sample treatment (i.e. dilution, filtration, pH adjustment). The paper-based platform was employed to detect paraoxon, 2,4-dichlorophenoxyacetic acid, and atrazine by exploiting the capability of these different types of pesticides (i.e. organophosphorus insecticides, phenoxy-acid herbicides, and triazine herbicide) to inhibit butyrylcholinesterase, alkaline phosphatase, and tyrosinase, respectively. The degree of inhibition correlating to the quantity of pesticides was evaluated by chronoamperometrically monitoring the enzymatic activity in the absence and in the presence of pesticides by using a portable potentiostat. To improve the sensitivity, the paper-based electrodes were modified with carbon black alone in the case of platforms for 2,4-dichlorophenoxyacetic acid and atrazine detection, or decorated with Prussian blue nanoparticles for the detection of paraoxon. The paper-based device was applied for the detection of paraoxon, 2,4-dichlorophenoxyacetic acid, and atrazine at ppb level in both standard solutions and river water sample. The accuracy of this origami multiple paper-based electrochemical biosensor was evaluated in river water by recovery studies, obtaining satisfactory values (e.g. for paraoxon 90 ± 1% and 88 ± 2%, for 10 and 20 ppb, respectively). The proposed three-dimensional origami paper device allows for rapid, cost-effective and accurate pesticide detection in surface water as a result of combining filter and office papers, screen-printing, wax-printing and nanomaterial technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Green Chemistry: Theory and Practice
Anastas, P. T., & Warner, J. C. (1998) · Medical Entomology and Zoology · Cited by 8,599
Electrochemical Detection for Paper-Based Microfluidics
Dungchai, W., Chailapakul, O., & Henry, C. S. (2009) · Analytical Chemistry · doi:10.1021/ac9007573 · Cited by 1,224
Electrochemical sensing in paper-based microfluidic devices
Nie, Z., Nijhuis, C. A., Gong, J., Chen, X., Kumachev, A., Martinez, A. W., Narovlyansky, M., & Whitesides, G. M. (2010) · Lab Chip · doi:10.1039/b917150a · Cited by 929
Paper-based analytical devices for environmental analysis
Meredith, N. A., Quinn, C., Cate, D. M., Reilly, T. H., Volckens, J., & Henry, C. S. (2016) · The Analyst · doi:10.1039/c5an02572a · Cited by 299
Arduini, F., Ricci, F., Tuta, C. S., Moscone, D., Amine, A., & Palleschi, G. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.07.052 · Cited by 241
Self-citationKinetic characterization of the substrate specificity and mechanism of mushroom tyrosinase
Espı́n, J. C., Varón, R., Fenoll, L. G., Gilabert, M. A., Garcı́a-Ruiz, P. A., Tudela, J., & Garcı́a-Cánovas, F. (2000) · European Journal of Biochemistry · doi:10.1046/j.1432-1327.2000.01013.x · Cited by 230
Joshi, K. A., Tang, J. M., Haddon, R. C., et al. (2004) · Electroanalysis · doi:10.1002/elan.200403118 · Cited by 230
Novel reagentless paper-based screen-printed electrochemical sensor to detect phosphate
Cinti, S., Talarico, D., Palleschi, G., Moscone, D., & Arduini, F. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.03.011 · Cited by 195
Self-citationArduini, F., Cinti, S., Scognamiglio, V., Moscone, D., & Palleschi, G. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.12.035 · Cited by 177
Self-citationFrom the Bench to the Field in Low‐Cost Diagnostics: Two Case Studies
Kumar, A. A., Hennek, J. W., Smith, B. S., Kumar, S., Beattie, P., Jain, S., Rolland, J. P., Stossel, T. P., Chunda‐Liyoka, C., & Whitesides, G. M. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201411741 · Cited by 163
Cited by
Carbon black as an outstanding and affordable nanomaterial for electrochemical (bio)sensor design
Arduini, F., Cinti, S., Mazzaracchio, V., Scognamiglio, V., Amine, A., & Moscone, D. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112033 · Cited by 298
Self-citationBiotechnological Advances in the Design of Algae-Based Biosensors
Antonacci, A., & Scognamiglio, V. (2020) · Trends in Biotechnology · doi:10.1016/j.tibtech.2019.10.005 · Cited by 87
Metadata
- Authors
- Arduini, F., Cinti, S., Caratelli, V., Amendola, L., Palleschi, G., & Moscone, D.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2019-02
- Volume
- 126
- Pages
- 346-354
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2896409164
- Cited by
- 322
- References
- 20
- FWCI
- 11.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Origami multiple paper-based electrochemical biosensors for pesticide detection. https://app.cochat.ai/papers/10.1016/j.bios.2018.10.014
- The paper
- Arduini, F., Cinti, S., Caratelli, V., Amendola, L., Palleschi, G., & Moscone, D. (2019). Origami multiple paper-based electrochemical biosensors for pesticide detection. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2018.10.014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.