The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Molecularly-imprinted chloramphenicol sensor with laser-induced graphene electrodes
Open accessAbstract
Graphene has emerged as a novel material with enhanced electrical and structural properties that can be used for a multitude of applications from super-capacitors to biosensors. In this context, an ultra-sensitive biosensor was developed using a low-cost, simple and mask-free method based on laser-induced graphene technique for electrodes patterning. The graphene was produced on a polyimide substrate, showing a porous multi-layer structure with a resistivity of 102.4 ± 7.3 Ω/square. The biosensor was designed as a 3-electrode system. Auxiliary and working electrodes were made of graphene by laser patterning and the reference electrode was handmade by casting a silver ink. A molecularly-imprinted polymer (MIP) was produced at the working electrode by direct electropolymerization of eriochrome black T (EBT). As proof-of-concept, the MIP film was tailored for chloramphenicol (CAP), a common contaminant in aquaculture. The resulting device was evaluated by cyclic voltammetry and electrochemical impedance spectroscopy readings against a redox standard probe. The limit of detection (LOD) was 0.62 nM and the linear response ranged from 1 nM to 10 mM. These analytical features were better than those produced by assembling the same biorecognition element on commercial graphene- and carbon-based screen-printed electrodes. Overall, the simplicity and quickness of the laser-induced graphene technique, along with the better analytical features obtained with the graphene-based electrodes, shows the potential to become a commercial approach for on-site sensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137
Cited by
Laser Fabrication of Graphene‐Based Flexible Electronics
You, R., Liu, Y., Hao, Y., Han, D., Zhang, Y., & You, Z. (2020) · Advanced Materials · doi:10.1002/adma.201901981 · Cited by 542
Vivaldi, F. M., Dallinger, A., Bonini, A., Poma, N., Sembranti, L., Biagini, D., Salvo, P., Greco, F., & Di Francesco, F. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c05614 · Cited by 364
Metadata
- Authors
- Cardoso, A. R., Marques, A. C., Santos, L., Carvalho, A. F., Costa, F. M., Martins, R., Sales, M. G. F., & Fortunato, E.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 124-125
- Pages
- 167-175
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2896735200
- Cited by
- 205
- References
- 1
- FWCI
- 7.53
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Molecularly-imprinted chloramphenicol sensor with laser-induced graphene electrodes. https://app.cochat.ai/papers/10.1016/j.bios.2018.10.015
- The paper
- Cardoso, A. R., Marques, A. C., Santos, L., Carvalho, A. F., Costa, F. M., Martins, R., Sales, M. G. F., & Fortunato, E. (2019). Molecularly-imprinted chloramphenicol sensor with laser-induced graphene electrodes. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2018.10.015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.