Electrochemical dual-aptamer-based biosensor for nonenzymatic detection of cardiac troponin I by nanohybrid electrocatalysts labeling combined with DNA nanotetrahedron structure

Sun, Duanping, Luo, Zibin, Lu, Jing, Zhang, Shangshi, Che, Tong, Chen, Zuanguang, Zhang, Luyong · 2019 · Biosensors and Bioelectronics

Abstract

The accurate detection of biomarkers for acute myocardial infarction (AMI) plays an important role in clinical diagnosis and management process. In this work, we developed an electrochemical biosensor by using magnetic metal organic framework (MMOF) nanocatalysts and DNA nanotetrahedron (NTH) based dual-aptamer probes for nonenzymatic detection of cardiac troponin I (cTnI), a gold standard biomarker for the early diagnosis of AMI. Firstly, the NTH-assisted dual-aptamer (Tro4 and Tro6) capture probes were immobilized on the screen-printed gold electrode (SPGE) for the highly enhanced capture the target cTnI with steady support and optimized interface density. Then, the MMOF Fe3O4@UiO-66 nanozymes were decorated by bimetallic Cu@Au nanoparticles and two kinds of aptamer. This fabricated nonenzymatic nanoprobe1 (NP1) can be applied for recognizing the cTnI specifically and amplifying the current signal by catalyzing the oxidation of hydroquinone (HQ) to benzoquinone (BQ) with H2O2. The target proteins were captured to fabricate a supersandwich-like structure on a SPGE interface. Furthermore, the nanoprobe2 (NP2) of Cu@Au nanozymes labeled with dual-complementary DNA (cDNA) to the dual-aptamer, were anchored on the NP1 through DNA hybridization, leading to the formation of cluster-based nanoprobes for further enhancing detection sensitivity. Finally, this enzyme-free electrochemical aptasensor exhibited great analytical performance with a dynamic range of 0.05-100 ng/mL, a low detection limit of 16 pg/mL, high selectivity and good repeatability. The fabricated aptasensor has great potential development in the field of clinic disease diagnostics for AMI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2019.03.049

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 177

Metadata

Authors
Sun, D., Luo, Z., Lu, J., Zhang, S., Che, T., Chen, Z., & Zhang, L.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2019-06
Volume
134
Pages
49-56
ISSN
0956-5663 (ISSN-L)
OpenAlex
W2925756087
Cited by
177
References
1
FWCI
6.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrochemical dual-aptamer-based biosensor for nonenzymatic detection of cardiac troponin I by nanohybrid electrocatalysts labeling combined with DNA nanotetrahedron structure. https://app.cochat.ai/papers/10.1016/j.bios.2019.03.049
The paper
Sun, D., Luo, Z., Lu, J., Zhang, S., Che, T., Chen, Z., & Zhang, L. (2019). Electrochemical dual-aptamer-based biosensor for nonenzymatic detection of cardiac troponin I by nanohybrid electrocatalysts labeling combined with DNA nanotetrahedron structure. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2019.03.049

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.