Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 201

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Molecularly imprinted polymer-decorated signal on-off ratiometric electrochemical sensor for selective and robust dopamine detection

Yang, Jiao, Hu, Yue, Li, Yingchun · 2019 · Biosensors and Bioelectronics

Abstract

Dopamine (DA), as one of the central neurotransmitters, plays an important role in many physiological and pathological processes. Detection of DA is critical to diagnose and monitor some neurological diseases. In this work, a novel on-off ratiometric electrochemical sensor with molecularly imprinted polymers (MIPs) as target molecule recognizer has been developed for selective and accurate detection of DA. Nanoporous gold (NPG) was electrodeposited on bare gold electrode, which not only benefited the output signal amplification, but also provided enlarged surface for immobilization of polythionine (pThi) and MIPs. Oxidation of DA and pThi served as response signal and internal reference signal, respectively. The oxidation peak currents of DA at +0.12 V increased with increasing the concentration of DA, while the peak currents of pThi at -0.2 V decreased simultaneously. Due to the specificity from MIPs and the built-in correction from pThi, the fabricated sensor showed excellent performance in view of selectivity and reproducibility. It's worth to mention that even if the surface area and morphology of working electrode underwent huge variation deliberately, the assay deviation among these ratiometric sensors was largely reduced around 10 times. The proposed sensor demonstrated a broad dynamic range of 0.3-100 μM, as well as a low detection limit of 0.1 μM (S/N = 3). Moreover, superior anti-interfering ability toward DA detection was obtained despite the presence of interferents at high concentration in artificial cerebrospinal fluid (aCSF). Therefore, this work is expected to provide an alternative pathway for constructing ratiometric electrochemical sensor and offer reliable determination of small molecules with high selectivity and stability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2019.03.054

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 201

Metadata

Authors
Yang, J., Hu, Y., & Li, Y.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2019-06
Volume
135
Pages
224-230
ISSN
0956-5663 (ISSN-L)
OpenAlex
W2927450337
Cited by
201
References
1
FWCI
8.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.