The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A ratiometric fluorescence platform based on boric-acid-functional Eu-MOF for sensitive detection of H2O2 and glucose
Abstract
A Eu-metal organic framework (Eu-MOF) probe with dual-emission was reported for the ratiometric fluorescence detection of H2O2 and glucose. Because of the special nucleophilic reaction between boric group and H2O2, Eu3+ and 5-boronobenzene-1,3-dicarboxylic acid (BBDC) were selected to synthesize the functional MOF probe via a simple one-pot solvothermal method. The Eu-MOF shows dual-emission at 370 and 623 nm with the single excitation at 270 nm due to the energy transfer efficiency change for antenna effect procedure. After addition of H2O2, the red emission of Eu-MOF weakened and the blue emission enhances immediately under 270 nm irradiation, so the ratiometric fluorescence detection is established. Moreover, the obvious color change for visual measuring of H2O2 and glucose is illustrated to reveal the merit of Eu-MOF probe. The proposed method was demonstrated to be highly sensitive and selective for H2O2 and glucose, with the low detection limits of 0.0335 and 0.0643 μM, respectively. The established boric-acid-functional Eu-MOF sensing platform was proved as the powerful probe for H2O2 and the metabolites involved in H2O2-generating reaction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mitochondrial Dysfunction and Oxidative Stress in Neurodegenerative Diseases
Lin, M. T., & Beal, M. F. (2006) · Nature · doi:10.1038/nature05292 · Cited by 6,455
Cited by
Fe–N–C Single-Atom Nanozymes for the Intracellular Hydrogen Peroxide Detection
Jiao, L., Xu, W., Yan, H., Wu, Y., Liu, C., Du, D., Lin, Y., & Zhu, C. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02901 · Cited by 364
Energy Transfer in Metal–Organic Frameworks for Fluorescence Sensing
Wang, J.-X., Yin, J., Shekhah, O., Bakr, O. M., Eddaoudi, M., & Mohammed, O. F. (2022) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c24759 · Cited by 300
Metadata
- Authors
- Cui, Y., Chen, F., & Yin, X.-B.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2019-06
- Volume
- 135
- Pages
- 208-215
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2937094577
- Cited by
- 296
- References
- 1
- FWCI
- 12.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A ratiometric fluorescence platform based on boric-acid-functional Eu-MOF for sensitive detection of H2O2 and glucose. https://app.cochat.ai/papers/10.1016/j.bios.2019.04.008
- The paper
- Cui, Y., Chen, F., & Yin, X.-B. (2019). A ratiometric fluorescence platform based on boric-acid-functional Eu-MOF for sensitive detection of H2O2 and glucose. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2019.04.008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.