Bimetallic cerium and ferric oxides nanoparticles embedded within mesoporous carbon matrix: Electrochemical immunosensor for sensitive detection of carbohydrate antigen 19-9

Wang, Minghua, Hu, Mengyao, Hu, Bin, Guo, Chuanpan, Song, Yingpan, Jia, Qiaojuan, He, Linghao, Zhang, Zhihong, Fang, Shaoming · 2019 · Biosensors and Bioelectronics

Abstract

A label-free electrochemical immunosensor was successfully developed for sensitively detecting carbohydrate antigen 19-9 (CA19-9) as a cancer marker. To achieve this, a series of bimetallic cerium and ferric oxide nanoparticles embedded within the mesoporous carbon matrix (represented by CeO2/FeOx@mC) was obtained from the bimetallic CeFe-based metal organic framework (CeFe-MOF) by calcination at different high temperatures. The formed CeO2 or FeOx nanoparticles were uniformly distributed within the highly graphitized mesoporous carbon matrix at the calcination temperature of 500 °C (represented by CeO2/FeOx@mC500). However, the obtained nanoparticles were aggregated into large size when calcined at the temperatures of 700 and 900 °C. The CA 19-9 antibody can be anchored to the CeO2/FeOx@mC network through chemical absorption between carboxylic groups of antibody and CeO2 or FeOx by ester-like bridging. The CeO2/FeOx@mC500-based immunosensor displayed superior sensing performance to the pristine CeFe-MOF, CeO2/FeOx@mC700- and CeO2/FeOx@mC900-based ones. Electrochemical impedance spectroscopy results showed that the developed immunosensor exhibited an extremely low detection limit of 10 μU·mL-1 (S/N = 3) within a wide range from 0.1 mU·mL-1 to 10 U·mL-1 toward CA 19-9. It also illustrated excellent specificity, good reproducibility and stability, and acceptable application analysis in the human serum solution which was diluted 100-fold with 0.01 M PBS solution (pH 7.4) and spiked with different amounts of CA19-9. Consequently, the proposed electrochemical immunosensor is capable enough of determining CA 19-9 in clinical diagnostics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2019.04.018

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 194

Metadata

Authors
Wang, M., Hu, M., Hu, B., Guo, C., Song, Y., Jia, Q., He, L., Zhang, Z., & Fang, S.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2019-06
Volume
135
Pages
22-29
ISSN
0956-5663 (ISSN-L)
OpenAlex
W2940339923
Cited by
194
References
1
FWCI
11.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bimetallic cerium and ferric oxides nanoparticles embedded within mesoporous carbon matrix: Electrochemical immunosensor for sensitive detection of carbohydrate antigen 19-9. https://app.cochat.ai/papers/10.1016/j.bios.2019.04.018
The paper
Wang, M., Hu, M., Hu, B., Guo, C., Song, Y., Jia, Q., He, L., Zhang, Z., & Fang, S. (2019). Bimetallic cerium and ferric oxides nanoparticles embedded within mesoporous carbon matrix: Electrochemical immunosensor for sensitive detection of carbohydrate antigen 19-9. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2019.04.018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.