The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Bimetallic cerium and ferric oxides nanoparticles embedded within mesoporous carbon matrix: Electrochemical immunosensor for sensitive detection of carbohydrate antigen 19-9
Abstract
A label-free electrochemical immunosensor was successfully developed for sensitively detecting carbohydrate antigen 19-9 (CA19-9) as a cancer marker. To achieve this, a series of bimetallic cerium and ferric oxide nanoparticles embedded within the mesoporous carbon matrix (represented by CeO2/FeOx@mC) was obtained from the bimetallic CeFe-based metal organic framework (CeFe-MOF) by calcination at different high temperatures. The formed CeO2 or FeOx nanoparticles were uniformly distributed within the highly graphitized mesoporous carbon matrix at the calcination temperature of 500 °C (represented by CeO2/FeOx@mC500). However, the obtained nanoparticles were aggregated into large size when calcined at the temperatures of 700 and 900 °C. The CA 19-9 antibody can be anchored to the CeO2/FeOx@mC network through chemical absorption between carboxylic groups of antibody and CeO2 or FeOx by ester-like bridging. The CeO2/FeOx@mC500-based immunosensor displayed superior sensing performance to the pristine CeFe-MOF, CeO2/FeOx@mC700- and CeO2/FeOx@mC900-based ones. Electrochemical impedance spectroscopy results showed that the developed immunosensor exhibited an extremely low detection limit of 10 μU·mL-1 (S/N = 3) within a wide range from 0.1 mU·mL-1 to 10 U·mL-1 toward CA 19-9. It also illustrated excellent specificity, good reproducibility and stability, and acceptable application analysis in the human serum solution which was diluted 100-fold with 0.01 M PBS solution (pH 7.4) and spiked with different amounts of CA19-9. Consequently, the proposed electrochemical immunosensor is capable enough of determining CA 19-9 in clinical diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hidalgo, M. (2010) · New England Journal of Medicine · doi:10.1056/nejmra0901557 · Cited by 2,570
Cited by
Nano Biosensors: Properties, applications and electrochemical techniques
Huang, X., Zhu, Y., & Kianfar, E. (2021) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2021.03.048 · Cited by 489
Metal-organic frameworks (MOFs) and MOF composites based biosensors
Mohanty, B., Kumari, S., Yadav, P., Kanoo, P., & Chakraborty, A. (2024) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2024.216102 · Cited by 440
Metadata
- Authors
- Wang, M., Hu, M., Hu, B., Guo, C., Song, Y., Jia, Q., He, L., Zhang, Z., & Fang, S.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2019-06
- Volume
- 135
- Pages
- 22-29
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2940339923
- Cited by
- 194
- References
- 1
- FWCI
- 11.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bimetallic cerium and ferric oxides nanoparticles embedded within mesoporous carbon matrix: Electrochemical immunosensor for sensitive detection of carbohydrate antigen 19-9. https://app.cochat.ai/papers/10.1016/j.bios.2019.04.018
- The paper
- Wang, M., Hu, M., Hu, B., Guo, C., Song, Y., Jia, Q., He, L., Zhang, Z., & Fang, S. (2019). Bimetallic cerium and ferric oxides nanoparticles embedded within mesoporous carbon matrix: Electrochemical immunosensor for sensitive detection of carbohydrate antigen 19-9. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2019.04.018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.