The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
An ultrasensitive electrochemical aptasensor for the determination of tumor exosomes based on click chemistry
Abstract
Exosomes, lipid bilayer membrane vesicles, can guide various pathological and physiological processes. However, reliable, convenient and sensitive methods for exosome determination for early cancer diagnosis are still technically challenging. Herein, an electrochemical aptasensor based on click chemistry and the DNA hybridization chain reaction (HCR) for signal amplification has been developed for the ultrasensitive detection of tumor exosomes. CD63 aptamer was first immobilized on a glassy carbon electrode for capturing exosomes, and 4-oxo-2-nonenal alkyne (alkynyl-4-ONE) molecules, functionalized lipid electrophiles, were conjugated to the exosomes via the reaction of amino and aldehyde groups. Azide-labeled DNA probe as an anchor was then connected to the exosomes by copper (I)-catalyzed click chemistry. Signal amplification was achieved by HCR, and the numerous linked horseradish peroxidase (HRP) molecules could catalyze the reaction of o-phenylenediamine (OPD) and H2O2. The concentration of exosomes could be quantified by monitoring the electrochemical reduction current of 2,3-diaminophenazine (DAP). Under the optimal conditions, this method allowed the sensitive detection of exosomes in the range of 1.12 × 102 to 1.12 × 108 particles/μL with a limit of detection (LOD) of 96 particles/μL. Furthermore, the present assay enabled sensitive and accurate quantification of exosomes in human serum, and it has high potential for exosome analysis in clinical samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Extracellular vesicles: Exosomes, microvesicles, and friends
Raposo, G., & Stoorvogel, W. (2013) · Journal of Cell Biology · doi:10.1083/jcb.201211138 · Cited by 8,099
Surface Functionalization of Exosomes Using Click Chemistry
Smyth, T., Petrova, K., Payton, N. M., Persaud, I., Redzic, J. S., Graner, M. W., Smith-Jones, P., & Anchordoquy, T. J. (2014) · Bioconjugate Chemistry · doi:10.1021/bc500291r · Cited by 532
Cited by
Aptamer-Based Detection of Circulating Targets for Precision Medicine
Wu, L., Wang, Y., Xu, X., Liu, Y., Lin, B., Zhang, M., Zhang, J., Wan, S., Yang, C., & Tan, W. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01140 · Cited by 705
Review on Strategies and Technologies for Exosome Isolation and Purification
Chen, J., Li, P., Zhang, T., Xu, Z., Huang, X., Wang, R., & Du, L. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.811971 · Cited by 585
Biogenesis, Isolation, and Detection of Exosomes and Their Potential in Therapeutics and Diagnostics
Sonbhadra, S., Mehak, & Pandey, L. M. (2023) · Biosensors · doi:10.3390/bios13080802 · Cited by 97
Analysis of extracellular vesicles as emerging theranostic nanoplatforms
Xing, Y., Cheng, Z., Wang, R., Lv, C., James, T. D., & Yu, F. (2020) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213506 · Cited by 67
Metadata
- Authors
- An, Y., Jin, T., Zhu, Y., Zhang, F., & He, P.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2019-10
- Volume
- 142
- Pages
- 111503
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2961148088
- Cited by
- 168
- References
- 2
- FWCI
- 6.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.