The DOI matches its Crossref record.
Laser-induced noble metal nanoparticle-graphene composites enabled flexible biosensor for pathogen detection
Abstract
Noble metal nanoparticle-3D graphene hybrid nanocomposites possess the advantage of nanoparticles and graphene, which have attracted extensive interest. Here we developed a one-step laser induction method to prepare various noble metal nanoparticle-3D graphene nanocomposites. The nanocomposites were converted from polyimide film coated with the corresponding metal precursor-chitosan hydrogel ink. These nanoparticles including gold nanoparticles (AuNPs), silver nanoparticles (AgNPs), and platinum nanoparticles (PtNPs), were evenly distributed on the surface of porous 3D graphene. Furthermore, we prepared an AuNPs-3D graphene interdigitated array electrode using the one-step laser induction method, which was used to fabricate a flexible impedimetric immunosensor for the detection of Escherichia coli O157:H7. The immunosensor shows excellent performance including low detection limit, high selectivity, and great flexibility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kumar, R., Pérez del Pino, A., Sahoo, S., Singh, R. K., Tan, W. K., Kar, K. K., Matsuda, A., & Joanni, E. (2022) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2021.100981 · Cited by 275
Smart plant-wearable biosensor for in-situ pesticide analysis
Zhao, F., He, J., Li, X., Bai, Y., Ying, Y., & Ping, J. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112636 · Cited by 258
Self-citationPeng, B., Zhao, F., Ping, J., & Ying, Y. (2020) · Small · doi:10.1002/smll.202002681 · Cited by 224
Self-citationRecent Advancements of LSPR Fiber‐Optic Biosensing: Combination Methods, Structure, and Prospects
Zhang, H., Zhou, X., Li, X., Gong, P., Zhang, Y., & Zhao, Y. (2023) · Biosensors · doi:10.3390/bios13030405 · Cited by 99
“Variations in the size and shape of metal nanoparticles (NPs) lead to exhibiting different properties making LSPR fiber-optic biosensing highly flexible [15].”
BackgroundA Flexible Electrochemical Biosensor Based on NdNiO3 Nanotubes for Ascorbic Acid Detection
Rossato, J. H. H., Oliveira, M. E., Lopes, B. V., Gallo, B. B., La Rosa, A. B., Piva, E., Barba, D., Rosei, F., Carreño, N. L. V., & Escote, M. T. (2022) · ACS Applied Nano Materials · doi:10.1021/acsanm.1c03992 · Cited by 29
Metadata
- Authors
- You, Z., Qiu, Q., Chen, H., Feng, Y., Wang, X., Wang, Y., & Ying, Y.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2020-02
- Volume
- 150
- Pages
- 111896
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2989650681
- Cited by
- 161
- References
- 0
- FWCI
- 6.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Laser-induced noble metal nanoparticle-graphene composites enabled flexible biosensor for pathogen detection. https://app.cochat.ai/papers/10.1016/j.bios.2019.111896
- The paper
- You, Z., Qiu, Q., Chen, H., Feng, Y., Wang, X., Wang, Y., & Ying, Y. (2020). Laser-induced noble metal nanoparticle-graphene composites enabled flexible biosensor for pathogen detection. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2019.111896
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.