A Flexible Electrochemical Biosensor Based on NdNiO3 Nanotubes for Ascorbic Acid Detection
Abstract
Flexible and wearable electrochemical biosensors are considered a non-invasive tool for monitoring biological substances, thus attracting attention due to the simple assembly, fast response, ultra-sensitivity, and low cost. Among the substances detected by electrochemical methods, ascorbic acid (AA) stands out, as its presence in the body promotes adequate physiological functions of the immune, central nervous, and circulatory systems, thus preventing and treating various diseases. Herein, this work focuses on the use of nanostructured NdNiO 3 compounds in an alternative flexible biosensor for AA detection by electrochemical sensing. Here, 1D nanostructures of NdNiO 3 were obtained by wet pore filling of a mesoporous aluminum oxide template. To the best of our knowledge, no electrochemical biosensors using NdNiO 3 nanotubes supported onto GO flexible electrodes have been reported for AA or other bioanalyte detection. Next, an electrochemical biosensor for AA was built using a laser-induced graphene (GO) electrode and two different NdNiO 3 (NNO) nanotubes, one with an external diameter of 20 nm (NNO20) and the other with 100 nm (NNO100). The size effect and Ni 3+ /Ni 2+ ratio influence on the sensing properties can be verified through electrochemical characterization. The GO/NNO20 and GO/NNO100 biosensors presented a detection range of 30 to 1100 μmol L –1, but the minimum detectable limit (3.8 μmol L –1 ) and sensitivity (0.031 μA μM –1 cm –2 ) are significantly better for the GO/NNO100 device. These outstanding results make both devices competitive with other AA devices listed in the literature. We also simulated the biosensors’ real application and verified that these biosensors could detect AA in synthetic sweat and under application of mechanical deformations. Thus, the GO/NNO biosensors showed a promising alternative to the development of real-time monitoring, POC devices, and flexible wearable electrochemical devices to use in AA detection. Future works should address the potential to detect other bioanalytes.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Spin-coating and annealing methods were used to prepare NdNiO3 nanotubes, which were then utilized to modify electrodes for electrochemical biosensors.
“Figure 5C presents the spin-coating and annealing methods used to prepare NdNiO 3 nanotubes, which were then utilized to modify electrodes for the fabrication of electrochemical biosensors [104].”
From Design Strategies and Emerging Applications of Perovskite-Based Sensors (2025) · cites this paper as [104]
The NdNiO3 nanotube method showcased benefits of simplicity, low cost, and mild conditions.
“This method showcased the benefits of simplicity, low cost, and mild conditions.”
From Design Strategies and Emerging Applications of Perovskite-Based Sensors (2025) · cites this paper as [104]
Electrochemical characterization revealed that both sensors had a detection range of 30-1100 μmol/L, with the GO/NNO100 sensor outperforming in terms of detection limit (3.8 μmol/L) and sensitivity [0.031 μA/(μM•cm2)].
“Electrochemical characterization revealed that both sensors had a detection range of 30-1100 μmol/L, with the GO/ NNO 100 sensor outperforming in terms of detection limit (3.8 μmol/L) and sensitivity [0.031 μA/(μM•cm 2 )].”
From Design Strategies and Emerging Applications of Perovskite-Based Sensors (2025) · cites this paper as [104]
Rossato et al. developed a flexible electrochemical biosensor for ascorbic acid (AA) detection using nanostructured NdNiO3 compounds supported on GO electrodes.
“Rossato et al. [104] developed a flexible electrochemical biosensor for ascorbic acid (AA) detection using nanostructured NdNiO 3 compounds supported on GO electrodes.”
From Design Strategies and Emerging Applications of Perovskite-Based Sensors (2025) · cites this paper as [104]
They synthesized NdNiO3 nanotubes with diameters of 20 nm (NNO20) and 100 nm (NNO100) for the biosensor.
“They synthesized NdNiO 3 nanotubes with diameters of 20 nm (NNO 20 ) and 100 nm (NNO 100 ) for the biosensor.”
From Design Strategies and Emerging Applications of Perovskite-Based Sensors (2025) · cites this paper as [104]
This biosensor demonstrated promising performance for AA detection in synthetic sweat and under mechanical stress, highlighting potential for real-time monitoring, point-of-care devices, and wearable electrochemical sensors.
“This biosensor demonstrated promising performance for AA detection in synthetic sweat and under mechanical stress, highlighting their potential for real-time monitoring, point-of-care devices, and wearable electrochemical sensors (Figure 15A) [104].”
From Design Strategies and Emerging Applications of Perovskite-Based Sensors (2025) · cites this paper as [104]
Cites
Rare-earth nickelates <i>R</i> NiO <sub>3</sub> : thin films and heterostructures
Catalano, S., Gibert, M., Fowlie, J., Íñiguez, J., Triscone, J.-M., & Kreisel, J. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aaa37a · Cited by 453 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Design Strategies and Emerging Applications of Perovskite-Based Sensors
Li, Y., Ding, Y., Sun, J., Tan, S., Li, Y., Wang, X., Cai, J., Bai, J., Lv, X., Guo, W., et al. (2025) · SmartMat · doi:10.1002/smm2.70022 · Cited by 41 · see citing works
- Authors
- Rossato, J. H. H., Oliveira, M. E., Lopes, B. V., Gallo, B. B., La Rosa, A. B., Piva, E., Barba, D., Rosei, F., Carreño, N. L. V., & Escote, M. T.
- Affiliations
- Universidade Federal do ABC (BR)
- Universidade Federal de Pelotas (BR)
- Graduate Program in Materials Science and Engineering, Technology Development Center, Federal University of Pelotas , Pelotas, RS 96010-000, Brazil
- Department of Restorative Dentistry, Graduate Program in Dentistry, Federal University of Pelotas, Rua Gonçalves Chaves 457, Pelotas, RS 96015-560, Brazil
- Institut National de la Recherche Scientifique (CA)
- Corresponding author
- Escote, Marcia T.
- ORCID
- Venue
- ACS Applied Nano Materials
- Publisher
- American Chemical Society (ACS)
- Published
- 2022-02-25
- Volume
- 5
- Issue
- 3
- Pages
- 3394-3405
- ISSN
- 2574-0970 (ISSN-L)
- OpenAlex
- W4214699961
- Cited by
- 29
- References
- 1
- Citations by year
- 2025: 8 · 2024: 10 · 2023: 8 · 2022: 3
- FWCI
- 1.99
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- ACS Applied Nano Materials (publishedVersion)
- ArTS Archivio della ricerca di Trieste (University of Trieste https://www.units.it/) (submittedVersion)
- Funders
- Canada Research Chairs
- Fundação de Amparo à Pesquisa do Estado do Rio Grande do Sul (17/2551-0001 157-0)
- Fundação de Amparo à Pesquisa do Estado de São Paulo (2016/3575-2)
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (88882.451560/2019-01, 88887.310585/2018-00, 88887.370699/2019-00)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Keywords
- ascorbic acid detection, wearable sensors, laser-induced graphene, graphene electrodes, Ni3+/Ni2+ ratio, nanotube size effects, synthetic sweat, point-of-care monitoring, non-invasive monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review