The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Smartphone-assisted robust enzymes@MOFs-based paper biosensor for point-of-care detection
Abstract
Portable devices featured with fast analysis and affordable methodologies for clinical diagnostics have stimulated the rapid development of point-of-care (POC) technologies, potentially lowering the mortality rate. Herein, we demonstrated a portable, robust, and user-friendly intelligent metal-organic frameworks (MOFs) paper device, called smartphone-assisted biomimetic MOFs nanoreactor colorimetric paper (SBMCP), for on-demand POC detection of endogenous biomolecules. The concept of this paper platform was analogous to the intracellular cascades signal transduction, wherein the single/multiple enzymes components trapped within a ZIF-8 exoskeleton allowed the sensitive and selective recognition of target analyte via the accessible micropores network of ZIF-8, and then transferred the recognition event to a visual color signal based on the cascade reaction. Meanwhile, the ZIF-8 exoskeleton also endowed the enzymes with significantly elevated stability. As a result, this robust and portable SBMCP sensor enabled the on-site analysis of different important disease-related biomolecules through modulating the enzyme cascades, combining with a custom-designed smartphone application for signal readout. In the SBMCP assay, no sophisticated instruments or professional skill of the user was required, only 5 μL sample volume was needed, and the whole analysis process could be achieved within a portable MOFs paper and pervasive smartphone, endowing this new assay with the merits of low-cost, time-saving and easy-to-use. We demonstrated this SBMCP sensor was capable of real-time colorimetric detection of glucose and uric acid in diabetes and gout events. It is believed that this portable biosensor platform proposed herein potentially represents promising alternatives for POC diagnosis, especially applicable in developing world and resource-limited settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wasserman, D. H. (2009) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.90563.2008 · Cited by 384
Cited by
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
Abdelhamid, H. N., & Mathew, A. P. (2022) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214263 · Cited by 341
Metal–organic frameworks for chemical sensing devices
Olorunyomi, J. F., Geh, S. T., Caruso, R. A., & Doherty, C. M. (2021) · Materials Horizons · doi:10.1039/d1mh00609f · Cited by 327
Huang, S., Chen, G., & Ouyang, G. (2022) · Chemical Society Reviews · doi:10.1039/d1cs01011e · Cited by 311
Self-citationYan, T., Zhang, G., Chai, H., Qu, L., & Zhang, X. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.753692 · Cited by 59
Metadata
- Authors
- Kou, X., Tong, L., Shen, Y., Zhu, W., Yin, L., Huang, S., Zhu, F., Chen, G., & Ouyang, G.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2020-05
- Volume
- 156
- Pages
- 112095
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3007398514
- Cited by
- 161
- References
- 1
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Smartphone-assisted robust enzymes@MOFs-based paper biosensor for point-of-care detection. https://app.cochat.ai/papers/10.1016/j.bios.2020.112095
- The paper
- Kou, X., Tong, L., Shen, Y., Zhu, W., Yin, L., Huang, S., Zhu, F., Chen, G., & Ouyang, G. (2020). Smartphone-assisted robust enzymes@MOFs-based paper biosensor for point-of-care detection. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2020.112095
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.