Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 212

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Facile synthesis of magnetic hierarchical flower-like Co3O4 spheres: Mechanism, excellent tetra-enzyme mimics and their colorimetric biosensing applications

Liu, Xuan, Yan, Lu, Ren, Han, Cai, Yuanyuan, Liu, Chongyang, Zeng, Lingxing, Guo, Jing, Liu, Aihua · 2020 · Biosensors and Bioelectronics

Abstract

Magnetic hierarchical flower-like Co3O4 spheres (Co3O4 nanoflowers) were facilely prepared via one-step surfactant-free and template-free wet chemical route at room temperature. The formation mechanism of Co3O4 nanoflowers was explored. The as-prepared Co3O4 nanoflowers exhibited excellent tetra-enzyme mimetic activities, including oxidase-like, peroxidase-like, catalase-like and superoxide dismutase (SOD)-like activity. The catalytic mechanism of the Co3O4 nanoflowers was studied in detail. The oxidase-like catalytic activity of Co3O4 nanoflowers was derived from the inherent oxygen vacancies of Co3O4, while the peroxidase-like catalytic activity originated from the •OH radical generated by hydrogen peroxide (H2O2). Only one specific enzyme mimics reaction with Co3O4 nanoflowers can be obtained by inhibiting specifically other nanozymes via varying pH, adding appropriate scavengers or selecting its specific substrate. Further, the steady-state kinetic and catalytic performance of the oxidase-, peroxidase- and catalase mimics of Co3O4 nanoflowers were studied. Based on the oxidase-like and peroxidase-like activities of Co3O4 nanoflowers, bifunctional colorimetric sensing platforms were constructed for the sensitive detection of acid phosphatase (ACP) with the linear range of 0.1-25 U L-1 and H2O2 with the linear range of 4-400 μM. Further, it is capable of detecting ACP in serum samples and H2O2 in water samples, respectively. Thus, the tetra-enzyme mimetic Co3O4 nanoflowers show broad prospects in the fields of biosensors, tumor therapy, environmental monitoring and biocatalysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2020.112342

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 212

Metadata

Authors
Liu, X., Yan, L., Ren, H., Cai, Y., Liu, C., Zeng, L., Guo, J., & Liu, A.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2020-10
Volume
165
Pages
112342
ISSN
0956-5663 (ISSN-L)
OpenAlex
W3034398521
Cited by
212
References
1
FWCI
9.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Facile synthesis of magnetic hierarchical flower-like Co3O4 spheres: Mechanism, excellent tetra-enzyme mimics and their colorimetric biosensing applications. https://app.cochat.ai/papers/10.1016/j.bios.2020.112342
The paper
Liu, X., Yan, L., Ren, H., Cai, Y., Liu, C., Zeng, L., Guo, J., & Liu, A. (2020). Facile synthesis of magnetic hierarchical flower-like Co3O4 spheres: Mechanism, excellent tetra-enzyme mimics and their colorimetric biosensing applications. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2020.112342

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.