The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Electrochemical biosensor for ultrasensitive exosomal miRNA analysis by cascade primer exchange reaction and MOF@Pt@MOF nanozyme
Abstract
Exosomal miRNAs have been discovered as important and reliable biomarkers for early diagnosis of tumors. However, it is still challenging to achieve accurate determination of trace exosomal miRNAs in real samples. Herein, we report an electrochemical strategy based on the cascade primer exchange reaction (PER) with MOF@Pt@MOF nanozyme for ultrasensitive detection of exosomal miRNA. Target-triggered PER that only includes a gated hairpin, a primer, and DNA polymerase can produce a long single strand in an autonomous and isothermal manner. Then, the nascent strand releases the protector B used to blockade capture probes, resulting in the binding of the nanozyme to sensing interface. Under the catalysis of the nanozyme, hydrogen peroxide (H2O2) is decomposed into H2O and O2, thus producing an amplified electrochemical signal. Benefiting from the cascade PER and the noticeable catalytic activity of the multiple-layered nanozyme, the established biosensor shows high sensitivity with limit of detection down to 0.29 fM and high specificity that can distinguish homologous miRNAs with single base mismatch. The developed strategy allows discrimination of tumor cells and breast cancer patients by detecting exosomal miRNA-21, and the results of this biosensor are consistent with qRT-PCR. Therefore, the electrochemical strategy has wide potential in the early screening of tumors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The biology , function , and biomedical applications of exosomes
Kalluri, R., & LeBleu, V. S. (2020) · Science · doi:10.1126/science.aau6977 · Cited by 10,770
Highly multiplexed in situ protein imaging with signal amplification by Immuno-SABER
Saka, S. K., Wang, Y., Kishi, J. Y., Zhu, A., Zeng, Y., Xie, W., Kirli, K., Yapp, C., Cicconet, M., Beliveau, B. J., et al. (2018) · doi:10.1101/507566 · Cited by 485
Cited by
Advances in metal–organic framework-based nanozymes and their applications
Huang, X., Zhang, S., Tang, Y., Zhang, X., Bai, Y., & Pang, H. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214216 · Cited by 342
Daniel, M., Mathew, G., Anpo, M., & Neppolian, B. (2022) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2022.214627 · Cited by 294
Metadata
- Authors
- Li, X., Li, X., Li, D., Zhao, M., Wu, H., Shen, B., Liu, P., & Ding, S.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2020-11
- Volume
- 168
- Pages
- 112554
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3080651407
- Cited by
- 216
- References
- 2
- FWCI
- 7.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemical biosensor for ultrasensitive exosomal miRNA analysis by cascade primer exchange reaction and MOF@Pt@MOF nanozyme. https://app.cochat.ai/papers/10.1016/j.bios.2020.112554
- The paper
- Li, X., Li, X., Li, D., Zhao, M., Wu, H., Shen, B., Liu, P., & Ding, S. (2020). Electrochemical biosensor for ultrasensitive exosomal miRNA analysis by cascade primer exchange reaction and MOF@Pt@MOF nanozyme. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2020.112554
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.