The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Rapid detection of SARS-CoV-2 antibodies using electrochemical impedance-based detector
Open accessAbstract
Emerging novel human contagious viruses and pathogens put humans at risk of hospitalization and possibly death due to the unavailability of vaccines and drugs which may take years to develop. Coronavirus disease (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was classified as a pandemic by the World Health Organization and has caused over 550,000 deaths worldwide as of July 2020. Accurate and scalable point-of-care devices would increase screening, diagnosis, and monitoring of COVID-19 patients. Here, we demonstrate rapid label-free electrochemical detection of SARS-CoV-2 antibodies using a commercially available impedance sensing platform. A 16-well plate containing sensing electrodes was pre-coated with receptor binding domain (RBD) of SARS-CoV-2 spike protein, and subsequently tested with samples of anti-SARS-CoV-2 monoclonal antibody CR3022 (0.1 g/ml, 1.0 g/ml, 10 g/ml). Subsequent blinded testing was performed on six serum specimens taken from COVID-19 and non-COVID-19 patients (1:100 dilution factor). The platform was able to differentiate spikes in impedance measurements from a negative control (1% milk solution) for all CR3022 samples. Further, successful differentiation and detection of all positive clinical samples from negative control was achieved. Measured impedance values were consistent when compared to standard ELISA test results showing a strong correlation between them (R2 = 0:9). Detection occurs in less than five minutes and the well-based platform provides a simplified and familiar testing interface that can be readily adaptable for use in clinical settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Early transmission dynamics in Wuhan, China, of novel coronavirus-infected pneumonia
Li, Q., Guan, X., Wu, P., Wang, X., Zhou, L., Tong, Y., Ren, R., Leung, K. S. M., Lau, E. H. Y., Wong, J. Y., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2001316 · Cited by 16,575
Premkumar, L., Segovia-Chumbez, B., Jadi, R., Martinez, D. R., Raut, R., Markmann, A. J., Cornaby, C., Bartelt, L., Weiss, S., Park, Y., et al. (2020) · Science Immunology · doi:10.1126/sciimmunol.abc8413 · Cited by 868
Cited by
Laschuk, N. O., Easton, E. B., & Zenkina, O. V. (2021) · RSC Advances · doi:10.1039/d1ra03785d · Cited by 843
Metadata
- Authors
- Rashed, M. Z., Kopechek, J. A., Priddy, M. C., Hamorsky, K. T., Palmer, K. E., Mittal, N., Valdez, J., Flynn, J., & Williams, S. J.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 171
- Pages
- 112709
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3092145882
- Cited by
- 178
- References
- 2
- FWCI
- 4.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid detection of SARS-CoV-2 antibodies using electrochemical impedance-based detector. https://app.cochat.ai/papers/10.1016/j.bios.2020.112709
- The paper
- Rashed, M. Z., Kopechek, J. A., Priddy, M. C., Hamorsky, K. T., Palmer, K. E., Mittal, N., Valdez, J., Flynn, J., & Williams, S. J. (2021). Rapid detection of SARS-CoV-2 antibodies using electrochemical impedance-based detector. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2020.112709
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.