Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 178

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Rapid detection of SARS-CoV-2 antibodies using electrochemical impedance-based detector

Open access
Rashed, Mohamed Z., Kopechek, Jonathan A., Priddy, Mariah C., Hamorsky, Krystal T., Palmer, Kenneth E., Mittal, Nikhil, Valdez, Joseph, Flynn, Joseph, Williams, Stuart J.·2021·Biosensors and Bioelectronics

Abstract

Emerging novel human contagious viruses and pathogens put humans at risk of hospitalization and possibly death due to the unavailability of vaccines and drugs which may take years to develop. Coronavirus disease (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was classified as a pandemic by the World Health Organization and has caused over 550,000 deaths worldwide as of July 2020. Accurate and scalable point-of-care devices would increase screening, diagnosis, and monitoring of COVID-19 patients. Here, we demonstrate rapid label-free electrochemical detection of SARS-CoV-2 antibodies using a commercially available impedance sensing platform. A 16-well plate containing sensing electrodes was pre-coated with receptor binding domain (RBD) of SARS-CoV-2 spike protein, and subsequently tested with samples of anti-SARS-CoV-2 monoclonal antibody CR3022 (0.1 g/ml, 1.0 g/ml, 10 g/ml). Subsequent blinded testing was performed on six serum specimens taken from COVID-19 and non-COVID-19 patients (1:100 dilution factor). The platform was able to differentiate spikes in impedance measurements from a negative control (1% milk solution) for all CR3022 samples. Further, successful differentiation and detection of all positive clinical samples from negative control was achieved. Measured impedance values were consistent when compared to standard ELISA test results showing a strong correlation between them (R2 = 0:9). Detection occurs in less than five minutes and the well-based platform provides a simplified and familiar testing interface that can be readily adaptable for use in clinical settings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2020.112709

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Rashed, M. Z., Kopechek, J. A., Priddy, M. C., Hamorsky, K. T., Palmer, K. E., Mittal, N., Valdez, J., Flynn, J., & Williams, S. J.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2021-01
Volume
171
Pages
112709
ISSN
0956-5663 (ISSN-L)
OpenAlex
W3092145882
Cited by
178
References
2
FWCI
4.44
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rapid detection of SARS-CoV-2 antibodies using electrochemical impedance-based detector. https://app.cochat.ai/papers/10.1016/j.bios.2020.112709
The paper
Rashed, M. Z., Kopechek, J. A., Priddy, M. C., Hamorsky, K. T., Palmer, K. E., Mittal, N., Valdez, J., Flynn, J., & Williams, S. J. (2021). Rapid detection of SARS-CoV-2 antibodies using electrochemical impedance-based detector. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2020.112709

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.