The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Recent advances in gold nanoparticles-based biosensors for food safety detection
Abstract
Food safety issue remains a challenge worldwide. Common substances in food can pose a great threat to human health including but not limited to food borne-pathogens, heavy metals, mycotoxins, pesticides, herbicides, veterinary drugs, allergens and illegal additives. To develop rapid, low-cost, portable and on-site detection methods of those contaminants and allergens to ensure food safety, gold nanoparticles (AuNPs) of versatile shapes and morphologies such as nanorods, nanoclusters, nanoflowers, nanostars, nanocages, nanobipyramids and nanowires have been employed as probes because they possess extraordinary properties that can be used to design biosensors enabling detecting various contaminants and allergens. By means of surface modification, AuNPs can directly or indirectly sense specific targets based on different mechanisms, such as hydrogen bonds, nucleic acid hybridization, aptamer-target binding, antigen-antibody recognition, enzyme inhibition, and enzyme-mimicking activity. AuNPs can induce a distinct color change from red to blue when they transform from a monodispersed state to an aggregated state in liquid solution, which can be observed by naked eyes. If Raman molecules are functionalized on AuNPs, their aggregation will alter the interparticle distance and induce the surface-enhanced Raman scattering that can be employed for highly sensitive detection. Ultra-small AuNPs such as Au nanoclusters also feature in fluorescence that enable a fluorescent readout. The formats of AuNPs for food safety detection in real world range broadly including but not limited to films, fibers, liquid solutions, tapes, chips and lateral flow strips. In this review, recent applications of AuNPs-based biosensors for food safety detection will be discussed, mainly in the aspect of different contaminants and allergens encountered in food samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Toxicological effects of malachite green
Srivastava, S., Sinha, R., & Roy, D. (2004) · Aquatic Toxicology · doi:10.1016/j.aquatox.2003.09.008 · Cited by 1,532
Animals as sources of food-borne pathogens: a review
Heredia, N., & García, S. (2018) · Animal Nutrition · doi:10.1016/j.aninu.2018.04.006 · Cited by 554
Nanoparticles functionalised with reversible molecular and supramolecular switches
Klajn, R., Stoddart, J. F., & Grzybowski, B. A. (2010) · Chemical Society Reviews · doi:10.1039/b920377j · Cited by 517
Label-free imaging, detection, and mass measurement of single viruses by surface plasmon resonance
Wang, S., Shan, X., Patel, U., Huang, X., Lu, J., Li, J., & Tao, N. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1005264107 · Cited by 386
Surface-Enhanced Raman Spectroscopy Applied to Food Safety
Craig, A. P., França, A. S., & Irudayaraj, J. (2013) · Annual Review of Food Science and Technology · doi:10.1146/annurev-food-022811-101227 · Cited by 356
Plasmon-Based Colorimetric Nanosensors for Ultrasensitive Molecular Diagnostics
Tang, L., & Li, J. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00282 · Cited by 299
Zhang, H., Ma, X., Liu, Y., Duan, N., Wu, S., Wang, Z., & Xu, B. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.033 · Cited by 297
Recent advances in sample preparation techniques and methods of sulfonamides detection – A review
Dmitrienko, S. G., Kochuk, E. V., Apyari, V. V., Tolmacheva, V. V., & Zolotov, Y. A. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.08.023 · Cited by 240
McEvoy, J. D. G. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(02)00751-1 · Cited by 168
Lam, C., Lan, L. C. L., Che, X., Tam, S., Wong, S. S. Y., Chen, Y., Jin, J., Tao, S., Tang, X., Yuen, K., et al. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2008.12.035 · Cited by 150
Cited by
Ramesh, M., Janani, R., Deepa, C., & Rajeshkumar, L. (2022) · Biosensors · doi:10.3390/bios13010040 · Cited by 443
Kirubakaran, D., Wahid, J. B. A., Karmegam, N., Jeevika, R., Sellapillai, L., Rajkumar, M., & SenthilKumar, K. J. (2026) · Biomedical Materials & Devices · doi:10.1007/s44174-025-00295-4 · Cited by 281
Flexible Plasmonic Biosensors for Healthcare Monitoring: Progress and Prospects
Song, L., Chen, J., Xu, B. B., & Huang, Y. (2021) · ACS Nano · doi:10.1021/acsnano.1c07176 · Cited by 186
Metadata
- Authors
- Hua, Z., Yu, T., Liu, D., & Xianyu, Y.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2021-05
- Volume
- 179
- Pages
- 113076
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3128001346
- Cited by
- 393
- References
- 32
- FWCI
- 16.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recent advances in gold nanoparticles-based biosensors for food safety detection. https://app.cochat.ai/papers/10.1016/j.bios.2021.113076
- The paper
- Hua, Z., Yu, T., Liu, D., & Xianyu, Y. (2021). Recent advances in gold nanoparticles-based biosensors for food safety detection. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2021.113076
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.