Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 325

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Highly sensitive detection of malignant glioma cells using metamaterial-inspired THz biosensor based on electromagnetically induced transparency

Zhang, Jin, Mu, Ning, Liu, Longhai, Xie, Jianhua, Feng, Hua, Yao, Jianquan, Chen, Tunan, Zhu, Weiren·2021·Biosensors and Bioelectronics

Abstract

Metamaterial-inspired biosensors have been extensively studied recently years for fast and low-cost THz detection. However, only the variation of the resonance frequency has been closely concerned in such sensors so far, whiles the magnitude variation, which also provide important information of the analyte, has not been sufficiently analyzed. In this paper, by the observation of two degree of variations, we propose a label-free biosensing approach for molecular classification of glioma cells. The metamaterial biosensor consisting of cut wires and split ring resonators are proposed to realize polarization-independent electromagnetic induced transparency (EIT) at THz frequencies. Simulated results show that the EIT-like resonance experiences both resonance frequency and magnitude variations when the properties of analyte change, which is further explained with coupled oscillators model theory. The theoretical sensitivity of the biosensor is evaluated up to 496.01 GHz/RIU. In experiments, two types of glioma cells (mutant and wild-type) are cultured on the biosensor surface. The dependences of frequency shifts and the peak magnitude variations on the cells concentrations for different types give new perspective for molecular classification of glioma cells. The measured results indicate that the mutant and wild-type glioma cells can be distinguished directly by observing both the variations of EIT resonance frequency and magnitude at any cells concentrations without antibody introduction. Our metamaterial-based biosensor shows a great potential in the recognition of molecule types of glioma cells, opening alternative way to sensitive biosensing technology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2021.113241

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Metadata

Authors
Zhang, J., Mu, N., Liu, L., Xie, J., Feng, H., Yao, J., Chen, T., & Zhu, W.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2021-08
Volume
185
Pages
113241
ISSN
0956-5663 (ISSN-L)
OpenAlex
W3153919173
Cited by
325
References
34
FWCI
12.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly sensitive detection of malignant glioma cells using metamaterial-inspired THz biosensor based on electromagnetically induced transparency. https://app.cochat.ai/papers/10.1016/j.bios.2021.113241
The paper
Zhang, J., Mu, N., Liu, L., Xie, J., Feng, H., Yao, J., Chen, T., & Zhu, W. (2021). Highly sensitive detection of malignant glioma cells using metamaterial-inspired THz biosensor based on electromagnetically induced transparency. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2021.113241

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.