The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Highly sensitive detection of malignant glioma cells using metamaterial-inspired THz biosensor based on electromagnetically induced transparency
Abstract
Metamaterial-inspired biosensors have been extensively studied recently years for fast and low-cost THz detection. However, only the variation of the resonance frequency has been closely concerned in such sensors so far, whiles the magnitude variation, which also provide important information of the analyte, has not been sufficiently analyzed. In this paper, by the observation of two degree of variations, we propose a label-free biosensing approach for molecular classification of glioma cells. The metamaterial biosensor consisting of cut wires and split ring resonators are proposed to realize polarization-independent electromagnetic induced transparency (EIT) at THz frequencies. Simulated results show that the EIT-like resonance experiences both resonance frequency and magnitude variations when the properties of analyte change, which is further explained with coupled oscillators model theory. The theoretical sensitivity of the biosensor is evaluated up to 496.01 GHz/RIU. In experiments, two types of glioma cells (mutant and wild-type) are cultured on the biosensor surface. The dependences of frequency shifts and the peak magnitude variations on the cells concentrations for different types give new perspective for molecular classification of glioma cells. The measured results indicate that the mutant and wild-type glioma cells can be distinguished directly by observing both the variations of EIT resonance frequency and magnitude at any cells concentrations without antibody introduction. Our metamaterial-based biosensor shows a great potential in the recognition of molecule types of glioma cells, opening alternative way to sensitive biosensing technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Landy, N. I., Sajuyigbe, S., Mock, J. J., Smith, D. R., & Padilla, W. J. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.207402 · Cited by 7,646
Observation of electromagnetically induced transparency
Boller, K.-J., Imamoğlu, A., & Harris, S. E. (1991) · Physical Review Letters · doi:10.1103/physrevlett.66.2593 · Cited by 3,058
Active terahertz metamaterial devices
Chen, H.-T., Padilla, W. J., Zide, J. M. O., Gossard, A. C., Taylor, A. J., & Averitt, R. D. (2006) · Nature · doi:10.1038/nature05343 · Cited by 2,383
Glioblastoma and Other Malignant Gliomas: A Clinical Review
Omuro, A. (2013) · JAMA · doi:10.1001/jama.2013.280319 · Cited by 2,301
A Radioimmunoassay Using a Monoclonal Antibody to Monitor the Course of Epithelial Ovarian Cancer
Bast, R. C., Klug, T. L., John, E. S., Jenison, E., Niloff, J. M., Lazarus, H., Berkowitz, R. S., Leavitt, T., Griffiths, C. T., Parker, L., et al. (1983) · New England Journal of Medicine · doi:10.1056/nejm198310133091503 · Cited by 2,135
Plasmonic analogue of electromagnetically induced transparency at the Drude damping limit
Liu, N., Langguth, L., Weiss, T., Kästel, J., Fleischhauer, M., Pfau, T., & Giessen, H. (2009) · Nature Materials · doi:10.1038/nmat2495 · Cited by 1,828
Ghaffari, S., Chandorkar, S. A., Wang, S., Ng, E. J., Ahn, C. H., Hong, V., Yang, Y., & Kenny, T. W. (2014) · Scientific Reports · doi:10.1038/srep04331 · Cited by 1,521
Mid-infrared plasmonic biosensing with graphene
Rodrigo, D., Limaj, O., Janner, D., Etezadi, D., García de Abajo, F. J., Pruneri, V., & Altug, H. (2015) · Science · doi:10.1126/science.aab2051 · Cited by 1,462
Planar Metamaterial Analogue of Electromagnetically Induced Transparency for Plasmonic Sensing
Liu, N., Weiss, T., Mesch, M., Langguth, L., Eigenthaler, U., Hirscher, M., Sönnichsen, C., & Giessen, H. (2010) · Nano Letters · doi:10.1021/nl902621d · Cited by 1,256
Active control of electromagnetically induced transparency analogue in terahertz metamaterials
Gu, J., Singh, R., Liu, X., Zhang, X., Ma, Y., Zhang, S., Maier, S. A., Tian, Z., Azad, A. K., Chen, H.-T., et al. (2012) · Nature Communications · doi:10.1038/ncomms2153 · Cited by 1,225
All-dielectric metasurface analogue of electromagnetically induced transparency
Yang, Y., Kravchenko, I. I., Briggs, D. P., & Valentine, J. (2014) · Nature Communications · doi:10.1038/ncomms6753 · Cited by 1,116
Biomedical Applications of Terahertz Spectroscopy and Imaging
Yang, X., Zhao, X., Yang, K., Liu, Y., Liu, Y., Fu, W., & Luo, Y. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.04.008 · Cited by 968
Metamaterial Analog of Electromagnetically Induced Transparency
Papasimakis, N., Fedotov, V. A., Zheludev, N. I., & Prosvirnin, S. L. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.253903 · Cited by 906
Mid-Infrared Plasmonic Biosensing with Graphene
Rodrigo, D., Limaj, O., Janner, D., Etezadi, D., García de Abajo, F. J., Pruneri, V., & Altug, H. (2015) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 898
Making a tumour's bed: glioblastoma stem cells and the vascular niche
Gilbertson, R. J., & Rich, J. N. (2007) · Nature Reviews Cancer · doi:10.1038/nrc2246 · Cited by 715
Metamaterials Application in Sensing
Chen, T., Li, S., & Sun, H. (2012) · Sensors · doi:10.3390/s120302742 · Cited by 557
Self-citationActive Terahertz Metamaterial Devices
Chen, H.-T., O’Hara, J. F., Azad, A. K., Shrekenhamer, D., Padilla, W. J., Zide, J. M. O., Gossard, A. C., Averitt, R. D., & Taylor, A. J. (2008) · Frontiers in Optics 2008/Laser Science XXIV/Plasmonics and Metamaterials/Optical Fabrication and Testing · doi:10.1364/meta_plas.2008.mmd5 · Cited by 504
Xiao, S., Wang, T., Liu, T., Yan, X., Li, Z., & Xu, C. (2018) · Carbon · doi:10.1016/j.carbon.2017.10.035 · Cited by 471
Gunnarsdóttir, E. D., Nandineni, M. R., Li, M., Myles, S., Gil, D., Pakendorf, B., & Stoneking, M. (2012) · Nature Communications · doi:10.1038/ncomms1401 · Cited by 461
Yan, X., Yang, M., Zhang, Z., Liang, L., Wei, D., Wang, M., Zhang, M., Wang, T., Liu, L., Xie, J., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.11.014 · Cited by 375
Self-citationTassin, P., Zhang, L., Zhao, R., Jain, A., Koschny, T., & Soukoulis, C. M. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.187401 · Cited by 342
The potential of terahertz imaging for cancer diagnosis: A review of investigations to date.
Yu, C., Fan, S., Sun, Y., & Pickwell‐MacPherson, E. (2012) · PubMed · doi:10.3978/j.issn.2223-4292.2012.01.04 · Cited by 289
Significance of immunohistochemistry in breast cancer
Zaha, D. C. (2014) · World Journal of Clinical Oncology · doi:10.5306/wjco.v5.i3.382 · Cited by 277
Terahertz Pulsed Spectroscopy of Human Basal Cell Carcinoma
Wallace, V. P., Fitzgerald, A. J., Pickwell, E., Pye, R. J., Taday, P. F., Flanagan, N., & Ha, T. (2006) · Applied Spectroscopy · doi:10.1366/000370206778664635 · Cited by 225
Ding, J., Arigong, B., Ren, H., Zhou, M., Shao, J., Lu, M., Chai, Y., Lin, Y., & Zhang, H. (2014) · Scientific Reports · doi:10.1038/srep06128 · Cited by 169
Wei, Z., Li, X., Zhong, N., et al. (2016) · Plasmonics · doi:10.1007/s11468-016-0309-z · Cited by 99
Advances in Brain Tumor Surgery
Asthagiri, A. R., Pouratian, N., Sherman, J. H., Ahmed, G., & Shaffrey, M. E. (2007) · Neurologic Clinics · doi:10.1016/j.ncl.2007.07.006 · Cited by 91
Prognostic significance of IDH mutation in adult low-grade gliomas: a meta-analysis
Sun, H., Yin, L.-H., Li, S., Han, S., Song, G., Liu, N., & Yan, C. (2013) · Journal of Neuro-Oncology · doi:10.1007/s11060-013-1107-5 · Cited by 83
Hu, W. P., Hsu, H.-Y., Chiou, A. E. T., Tseng, K., Lin, H. Y., Geng, C., & Chen, S.-J. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.11.001 · Cited by 76
Label-free amplified bioaffinity detection using terahertz wave technology
Menikh, A., Mickan, S. P., Liu, H., MacColl, R., & Zhang, X.-C. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.03.006 · Cited by 72
Computer-aided prognosis on breast cancer with hematoxylin and eosin histopathology images: A review
Chen, J., Li, Y., Xu, J., Gong, L., Wang, L., Liu, W.-L., & Liu, J. (2017) · Tumor Biology · doi:10.1177/1010428317694550 · Cited by 71
Luo, W., Cai, W., Xiang, Y., Wang, L., Ren, M., Zhang, X., & Xu, J. (2016) · Optics Express · doi:10.1364/oe.24.005784 · Cited by 69
Recent advances in the metamaterial-inspired biosensors
Salim, A., & Lim, S. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.06.031 · Cited by 62
Ammonia as a case study for the spontaneous ionization of a simple hydrogen-bonded compound
Palasyuk, T., Troyan, I., Eremets, M., Drozd, V., Medvedev, S., Zaleski–Ejgierd, P., Magos–Palasyuk, E., Wang, H., Bonev, S. A., Dudenko, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms4460 · Cited by 58
Metadata
- Authors
- Zhang, J., Mu, N., Liu, L., Xie, J., Feng, H., Yao, J., Chen, T., & Zhu, W.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2021-08
- Volume
- 185
- Pages
- 113241
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3153919173
- Cited by
- 325
- References
- 34
- FWCI
- 12.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.