MXene-based enzymatic sensor for highly sensitive and selective detection of cholesterol
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In this work, the synthesized MXene (Ti3C2Tx) exhibited large specific area, biocompatibility, excellent electronic conductivity, and good dispersion in aqueous phase. The Chit/ChOx/Ti3C2Tx nanocomposite was prepared through the continuous self-assembled process. Its structure is characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and differential pulse voltammetry (DPV). Moreover, the biosensor for cholesterol detection was fabricated via a one-step dip-coating method. Chit andTi3C2Tx act as a support matrix to immobilize ChOx enzyme, and also play a role in increasing the electrical conductivity. Meanwhile, the addition of redox mediator (Fe(CN)63-/4-) facilitates the electron transport from the analyte to the modified electrode in the oxidation of cholesterol. The DPV response exhibited an increase in current with increasing cholesterol concentration. Under the optimum conditions, the DPV response of the biosensor indicated a good linear relationship with the concentration of cholesterol ranging from 0.3 to 4.5 nM with a low detection limit of 0.11 nM, and a high sensitivity of 132.66 μA nM-1 cm-2. In addition, with favorable selectivity and stability, the biosensor has been used to detect cholesterol in real samples and the results demonstrate that the biosensor has excellent practicability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-Dimensional Molybdenum Carbide (MXene) as an Efficient Electrocatalyst for Hydrogen Evolution
Seh, Z. W., Fredrickson, K. D., Anasori, B., Kibsgaard, J., Strickler, A. L., Lukatskaya, M. R., Gogotsi, Y., Jaramillo, T. F., & Vojvodic, A. (2016) · ACS Energy Letters · doi:10.1021/acsenergylett.6b00247 · Cited by 1,482
Liu, H., Duan, C., Yang, C., Shen, W., Wang, F., & Zhu, Z. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.04.090 · Cited by 475
Cited by
2D metal carbides and nitrides (MXenes) for sensors and biosensors
Alwarappan, S., Nesakumar, N., Sun, D., Hu, T. Y., & Li, C.-Z. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113943 · Cited by 262
Metadata
- Authors
- Xia, T., Liu, G., Wang, J., Hou, S., & Hou, S.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2021-07
- Volume
- 183
- Pages
- 113243
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3152923936
- Cited by
- 142
- References
- 2
- FWCI
- 6.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.