Microbial whole-cell biosensors: Current applications, challenges, and future perspectives
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Microbial Whole-Cell Biosensors (MWCBs) have seen rapid development with the arrival of 21st century biological and technological capabilities. They consist of microbial species which produce, or limit the production of, a reporter protein in the presence of a target analyte. The quantifiable signal from the reporter protein can be used to determine the bioavailable levels of the target analyte in a variety of sample types at a significantly lower cost than most widely used and well-established analytical instrumentation. Furthermore, the versatile and robust nature of MWCBs shows great potential for their use in otherwise unavailable settings and environments. While MWCBs have been developed for use in biomedical, environmental, and agricultural monitoring, they still face various challenges before they can transition from the laboratory into industrialized settings like their enzyme-based counterparts. In this comprehensive and critical review, we describe the underlying working principles of MWCBs, highlight developments for their use in a variety of fields, detail challenges and current efforts to address them, and discuss exciting implementations of MWCBs helping redefine what is thought to be possible with this expeditiously evolving technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogel: Preparation, characterization, and applications: A review
Ahmed, E. M. (2015) · Journal of Advanced Research · doi:10.1016/j.jare.2013.07.006 · Cited by 5,800
Revised Estimates for the Number of Human and Bacteria Cells in the Body
Sender, R., Fuchs, S., & Milo, R. (2016) · PLOS Biology · doi:10.1371/journal.pbio.1002533 · Cited by 5,425
Mylona, P., Pawlowski, K., & Bisseling, T. (1995) · The Plant Cell · doi:10.1105/tpc.7.7.869 · Cited by 692
An ingestible bacterial-electronic system to monitor gastrointestinal health
Mimee, M., Nadeau, P., Hayward, A., Carim, S., Flanagan, S., Jerger, L., Collins, J., McDonnell, S., Swartwout, R., Citorik, R. J., et al. (2018) · Science · doi:10.1126/science.aas9315 · Cited by 606
Producer–decomposer co-dependency influences biodiversity effects
Naeem, S., Hahn, D. R., & Schuurman, G. (2000) · Nature · doi:10.1038/35001568 · Cited by 261
Knecht, L. D., O'Connor, G., Mittal, R., Liu, X. Z., Daftarian, P., Deo, S. K., & Daunert, S. (2016) · EBioMedicine · doi:10.1016/j.ebiom.2016.05.037 · Cited by 132
Self-citationMedina-Rodriguez, E. M., Madorma, D., O’Connor, G., Mason, B. L., Han, D., Deo, S. K., Oppenheimer, M., Nemeroff, C. B., Trivedi, M. H., Daunert, S., et al. (2020) · American Journal of Psychiatry · doi:10.1176/appi.ajp.2020.19090960 · Cited by 110
Self-citationSequential binding and sensing of Zn(II) by Bacillus subtilis Zur
Ma, Z., Gabriel, S. E., & Helmann, J. D. (2011) · Nucleic Acids Research · doi:10.1093/nar/gkr625 · Cited by 98
Metadata
- Authors
- Moraskie, M., Roshid, M. H. O., O'Connor, G., Dikici, E., Zingg, J.-M., Deo, S., & Daunert, S.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2021-11
- Volume
- 191
- Pages
- 113359
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3164051821
- Cited by
- 209
- References
- 8
- FWCI
- 8.25
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microbial whole-cell biosensors: Current applications, challenges, and future perspectives. https://app.cochat.ai/papers/10.1016/j.bios.2021.113359
- The paper
- Moraskie, M., Roshid, M. H. O., O'Connor, G., Dikici, E., Zingg, J.-M., Deo, S., & Daunert, S. (2021). Microbial whole-cell biosensors: Current applications, challenges, and future perspectives. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2021.113359
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.