Advances in nucleic acid amplification techniques (NAATs): COVID-19 point-of-care diagnostics as an example
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Achieving superhigh sensitivity is the ultimate goal for bio-detection in modern analytical science and life science. Among variable signal amplification strategies, nucleic acid amplification technologies are revolutionizing the field of bio-detection, providing greater possibilities in novel diagnosis achieving high efficiency, specificity, and cost-effectiveness. Nucleic acid amplification techniques (NAATs), such as Polymerase Chain Reaction (PCR), Rolling Circle Amplification (RCA), Loop-Mediated Isothermal Amplification (LAMP), Recombinase Polymerase Amplification (RPA), CRISPR-related amplification, and others are dominating methods employed in research and clinical settings. They each provide distinctively unique features that can offer desirable performance in terms of sensitivity, specificity, simplicity, stability, and cost. NAATs are in unmet demand in molecular diagnosis, especially in point-of-care scenario. This review will discuss the principles and recent advancements of each NAAT, respectively, revealing their strengths and challenges in achieving rapid and accurate bio-detection with a focus on point-of-care diagnosis. Furthermore, this review will explore the application of each of the technologies through the contemporary COVID-19 pandemic, analyzing their ability in point-of-care diagnosis of the COVID-19 with high sensitivity to emphasize significance of developing NAATs based methods in battling COVID-19. Finally, advantages and potentials of each NAAT in enhancements of sensitivity and specificity in bio-detection from bench side to the bedside will be discussed, aiming for full exploitation of capability of each NAAT. This review will provide novel aspects in the selection and combination of usages of various NAATs based on their distinctive characteristics and limitations. A possible advancing direction of future accurate POCT is also proposed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805
Crystal structure of Cas9 in complex with guide RNA and target DNA
Nishimasu, H., Ran, F. A., Hsu, P. D., Konermann, S., Shehata, S. I., Dohmae, N., Ishitani, R., Zhang, F., & Nureki, O. (2014) · Cell · doi:10.1016/j.cell.2014.02.001 · Cited by 2,306
RNA targeting with CRISPR–Cas13
Abudayyeh, O. O., Gootenberg, J. S., Essletzbichler, P., Han, S., Joung, J., Belanto, J. J., Verdine, V., Cox, D. B. T., Kellner, M. J., Regev, A., et al. (2017) · Nature · doi:10.1038/nature24049 · Cited by 2,093
Point-of-Care RNA-Based Diagnostic Device for COVID-19
Yang, T., Wang, Y.-C., Shen, C.-F., & Cheng, C.-M. (2020) · Diagnostics · doi:10.3390/diagnostics10030165 · Cited by 137
Qiu, X., Nergiz, A. I., Maraolo, A. E., Bogoch, I. I., Low, N., & Cevik, M. (2021) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2021.01.011 · Cited by 135
Metadata
- Authors
- Kang, T., Lu, J., Yu, T., Long, Y., & Liu, G.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2022-06
- Volume
- 206
- Pages
- 114109
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W4214571968
- Cited by
- 227
- References
- 5
- FWCI
- 12.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.