Long-term complications of microtia reconstruction: A systematic review
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Microtia is a rare disorder characterized by malformation or even complete absence of the auricle. Reconstruction is often performed using autologous costal cartilage (ACC) or porous polyethylene implants (PPE). However, the long-term outcomes of both methods are unclear. OBJECTIVE: This systematic review aimed to analyze long-term complications and suggest minimal reporting criteria for future original data studies. METHODS: A systematic literature search was conducted in MEDLINE, EMBASE and the Cochrane Central Register of Controlled Trials from inception through October 14, 2020. Articles on auricular reconstruction in patients with microtia using ACC or PPE were included provided that the follow-up period was at least one year. This publication focused on long-term complications reported in patients with a postoperative follow-up period of at least one year. RESULTS: Twenty-nine publications reported on complications during long-term follow-up. Overall long-term complication rates were not reported. The incidence of individual complications during long-term follow-up was less than 10% after ACC reconstruction and less than 15% in PPE reconstruction. Framework resorption and wire exposure were reported even after an extended follow-up of more than five years after ACC reconstruction, while reports on the extended long-term results of PPE reconstruction are limited. Data synthesis was limited due to heterogeneity and poor study quality. CONCLUSIONS: Future studies should report on long-term complications including framework exposure or extrusion, graft loss, framework resorption, wire exposure and scalp and auricular scar complications. We recommend a surgical follow-up of at least five years.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rayyan-a web and mobile app for systematic reviews.
Ouzzani, M., Hammady, H., Fedorowicz, Z., & Elmagarmid, A. (2016) · Systematic Reviews · doi:10.1186/s13643-016-0384-4 · Cited by 26,092
Herzog, R., Álvarez-Pasquin, M. J., Díaz, C., Del Barrio, J. L., Estrada, J. M., & Gil, Á. (2013) · BMC Public Health · doi:10.1186/1471-2458-13-154 · Cited by 1,652
A new method of total reconstruction of the auricle for microtia
Nagata, S. (1993) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199308000-00001 · Cited by 640
Ear reconstruction using a porous polyethylene framework and temporoparietal fascia flap
Reinisch, J., & Lewin, S. (2009) · Facial Plastic Surgery · doi:10.1055/s-0029-1239448 · Cited by 203
Pre and post-operative psychological functioning in younger and older children with microtia
Johns, A. L., Lucash, R. E., Im, D. D., & Lewin, S. L. (2015) · Journal of Plastic, Reconstructive & Aesthetic Surgery · doi:10.1016/j.bjps.2014.12.019 · Cited by 99
Comparison of microtia reconstruction outcomes using rib cartilage vs porous polyethylene implant.
Constantine, K. K., Gilmore, J., Lee, K., & Leach, J. (2014) · JAMA Facial Plastic Surgery · doi:10.1001/jamafacial.2014.30 · Cited by 85
Autologous ear reconstruction for microtia does not result in loss of cutaneous sensitivity.
Denadai, R., Raposo-Amaral, C. E., Zanco, G. L., & Raposo- Amaral, C. A. (2019) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000005485 · Cited by 12
Thermosensitivity in a reconstructed microtic ear.
Öberg, M., Becker, M., Arktander, M., Centerman, M., Svensson, H., & Wikström, S. (2008) · Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery · doi:10.1080/02844310802098458 · Cited by 10
Threshold of tactile perception in a reconstructed auricle.
Öberg, M., Svensson, H., Becker, M., & Wikström, S.-O. (2011) · Journal of Plastic Surgery and Hand Surgery · doi:10.3109/2000656x.2010.542653 · Cited by 8
Cited by
Ronde, E. M., Esposito, M., Lin, Y., van Etten-Jamaludin, F. S., Bulstrode, N. W., & Breugem, C. C. (2021) · Journal of Plastic, Reconstructive & Aesthetic Surgery · doi:10.1016/j.bjps.2021.08.004 · Cited by 38
Varagur, K., Zubovic, E., Skolnick, G. B., Buss, J., Snyder-Warwick, A., Reinisch, J., & Patel, K. B. (2024) · The Cleft Palate-Craniofacial Journal · doi:10.1177/10556656221132034 · Cited by 7
Gates-Tanzer, L., Mullen, B., Srikumar, J., Mardini, S., Sharaf, B., Bite, U., & Gibreel, W. (2025) · Journal of Plastic, Reconstructive & Aesthetic Surgery · doi:10.1016/j.bjps.2025.01.019 · Cited by 5
Metadata
- Authors
- Ronde, E. M., Esposito, M., Lin, Y., van Etten-Jamaludin, F. S., Bulstrode, N. W., & Breugem, C. C.
- Venue
- Journal of Plastic, Reconstructive & Aesthetic Surgery
- Publisher
- Elsevier BV
- Published
- 2021-12
- Volume
- 74
- Issue
- 12
- Pages
- 3235-3250
- ISSN
- 1748-6815 (ISSN-L)
- OpenAlex
- W3194143204
- Cited by
- 53
- References
- 9
- FWCI
- 2.23
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.