Cited by 78Corneal surgery and disordersCorneal Surgery and TreatmentsCollagen: Extraction and Characterization

Quantification of Collagen Organization in the Peripheral Human Cornea at Micron-Scale Resolution

Open access
Boote, Craig, Kamma-Lorger, Christina S., Hayes, Sally, Harris, Jonathan, Burghammer, Manfred, Hiller, Jennifer, Terrill, Nicholas J., Meek, Keith M.·2011·Biophysical Journal

Abstract

The collagen microstructure of the peripheral cornea is important in stabilizing corneal curvature and refractive status. However, the manner in which the predominantly orthogonal collagen fibrils of the central cornea integrate with the circumferential limbal collagen is unknown. We used microfocus wide-angle x-ray scattering to quantify the relative proportion and orientation of collagen fibrils over the human corneolimbal interface at intervals of 50 μm. Orthogonal fibrils changed direction 1-1.5 mm before the limbus to integrate with the circumferential limbal fibrils. Outside the central 6 mm, additional preferentially aligned collagen was found to reinforce the cornea and limbus. The manner of integration and degree of reinforcement varied significantly depending on the direction along which the limbus was approached. We also employed small-angle x-ray scattering to measure the average collagen fibril diameter from central cornea to limbus at 0.5 mm intervals. Fibril diameter was constant across the central 6 mm. More peripherally, fibril diameter increased, indicative of a merging of corneal and scleral collagen. The point of increase varied with direction, consistent with a scheme in which the oblique corneal periphery is reinforced by chords of scleral collagen. The results have implications for the cornea's biomechanical response to ocular surgeries involving peripheral incision.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bpj.2011.05.029

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • It seems likely that alterations in tissue thickness from central cornea to limbus in human corneas are due to an increase in the amount of collagen in the peripheral stroma.

    “although water distribution from central cornea to limbus is not known for human corneas, it seems likely that alterations in tissue thickness are due to an increase in the amount of collagen in the peripheral stroma (Aghamohammadzadeh et al., 2004, Boote et al., 2011, Henriksson et al., 2012).”

    From Corneal structure and transparency (2015) · cites this paper as Boote et al., 2011

  • This network seems to contain collagen fibrils with a larger diameter than those in the central cornea.

    “and seems to contain collagen fibrils with a larger diameter to those in the central cornea (Boote et al., 2011).”

    From Corneal structure and transparency (2015) · cites this paper as Boote et al., 2011

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. [19]19. Maurice, D. M. 1984. The cornea and sclera. In The Eye. H. Davson, editor. Academic Press, Orlando, FL. 1-158.

Cited by

Sorted by citations

Authors
Boote, C., Kamma-Lorger, C. S., Hayes, S., Harris, J., Burghammer, M., Hiller, J., Terrill, N. J., & Meek, K. M.
Affiliations
  • Cardiff University (GB)
  • European Synchrotron Radiation Facility (FR)
  • Diamond Light Source (GB)
Corresponding author
Meek, Keith M.
Venue
Biophysical Journal
Publisher
Elsevier BV
Published
2011-07
Volume
101
Issue
1
Pages
33-42
ISSN
0006-3495 (ISSN-L)
OpenAlex
W2017767113
Cited by
78
References
1
Citations by year
2026: 1 · 2025: 4 · 2024: 5 · 2023: 8 · 2022: 5 · 2021: 8 · 2020: 7 · 2019: 4 · 2018: 5 · 2017: 2 · 2016: 10 · 2015: 6 · 2014: 5 · 2013: 6 · 2012: 2
FWCI
3.03
Type
journal article
Language
en
Open access
Locations
  • Biophysical Journal (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • ORCA Online Research @Cardiff (Cardiff University) (submittedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal Surgery and Treatments
  • Physical Sciences › Materials Science › Biomaterials › Collagen: Extraction and Characterization
Keywords
limbus, collagen fibril orientation, collagen fibril diameter, scleral collagen, corneal biomechanics, corneal curvature, peripheral cornea
MeSH terms
Aged, Aged, 80 and over, Collagen, Cornea, Humans, Middle Aged, Models, Biological, X-Ray Diffraction, Limbus Corneae, Fibrillar Collagens

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review