Repetitive transcranial magnetic stimulation: Hearing safety considerations
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND The guidelines for use of repetitive transcranial magnetic stimulation (rTMS) advise frequent updating of rTMS safety guidelines and recommendations. Although rTMS can produce sound of more than 120 dB C, which is sufficient to induce hearing loss, the effect of rTMS noise on the hearing of both patients and rTMS practitioners is understudied. OBJECTIVE This study investigated the effects of rTMS noise on subjects' hearing using otoacoustic emissions evoked by clicks (transiently evoked otoacoustic emissions, TEOAEs), which is an objective and sensitive method of cochlear exploration. METHODS Hearing thresholds and TEOAEs were recorded in 24 normal-hearing healthy subjects before and after a real or sham rTMS session (a single 20-minute session applied to the superior temporal gyrus with 1200 pulses at 100% of the individual motor threshold). RESULTS No significant difference in hearing thresholds was observed between subjects exposed to real or sham rTMS. However, the difference in TEOAE amplitude between pre- and post-rTMS sessions increased significantly with rTMS noise for those subjects the least protected by earplugs, showing a post-rTMS slight decrease of TEOAE amplitude for high rTMS intensities and hence minor hearing function alteration. However, this correlation was no longer found 1 hour after the rTMS session. CONCLUSIONS These findings suggest that, even when rTMS is used within normal safety limits and with good hearing protection, rTMS noise can transiently disturb hearing mechanisms in normal-hearing healthy subjects. This transient effect of rTMS on hearing may be an important consideration for Institutional Review Boards when rTMS is used at higher stimulation intensities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
O’Reardon, J. P., Solvason, H. B., Janicak, P. G., Sampson, S., Isenberg, K. E., Nahas, Z., McDonald, W. M., Avery, D., Fitzgerald, P. B., Loo, C., et al. (2007) · Biological Psychiatry · doi:10.1016/j.biopsych.2007.01.018 · Cited by 1,910
Pascual-Leone, A., Rubio, B., Pallardó, F., & Catalá, M. D. (1996) · The Lancet · doi:10.1016/s0140-6736(96)01219-6 · Cited by 1,229
Agrawal, Y. (2008) · Archives of Internal Medicine · doi:10.1001/archinte.168.14.1522 · Cited by 977
Transcranial magnetic stimulation and cognitive neuroscience
Walsh, V., & Cowey, A. (2000) · Nature Reviews Neuroscience · doi:10.1038/35036239 · Cited by 814
Is there a future for therapeutic use of transcranial magnetic stimulation?
Ridding, M. C., & Rothwell, J. C. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2169 · Cited by 687
Cited by
Lefaucheur, J.-P., André-Obadia, N., Antal, A., Ayache, S. S., Baeken, C., Benninger, D. H., Cantello, R. M., Cincotta, M., de Carvalho, M., De Ridder, D., et al. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.05.021 · Cited by 2,119
Perera, T., George, M. S., Grammer, G., Janicak, P. G., Pascual-Leone, A., & Wirecki, T. S. (2016) · Brain Stimulation · doi:10.1016/j.brs.2016.03.010 · Cited by 674
“Therefore, an additional standard safety precaution for all TMS treatments is the use of earplugs or other hearing protection capable of at least 30 dB sound reduction [57].”
BackgroundUltrasound Technologies for Imaging and Modulating Neural Activity
Rabut, C., Yoo, S., Hurt, R. C., Jin, Z., Li, H., Guo, H., Ling, B., & Shapiro, M. G. (2020) · Neuron · doi:10.1016/j.neuron.2020.09.003 · Cited by 249
“As has been done with transcranial magnetic stimulation (Foysal and Baker, 2020; Tringali et al., 2012) and transcranial direct current stimulation (tDCS) (Matsumoto and Ugawa, 2016), sensory side effects must be comprehensively studied and understood to enable the design of adequate sham controls.”
BackgroundSchönfeldt-Lecuona, C., Cárdenas-Morales, L., Moreno-Aguirre, A., Dorn, K., Langguth, B., Brühl, A. B., Kammer, T., & Herwig, U. (2012) · Brain Topography · doi:10.1007/s10548-012-0218-1 · Cited by 15
“participants which used transiently evoked otoacoustic emissions (TEOAEs) to assess the effect of single sessions of 1 or 10 Hz rTMS (100% RMT, each in 8 subjects) on cochlear functioning (Tringali et al. 2011).”
BackgroundMethodResultInfluential
Metadata
- Authors
- Tringali, S., Perrot, X., Collet, L., & Moulin, A.
- Venue
- Brain Stimulation
- Publisher
- Elsevier BV
- Published
- 2012-07
- Volume
- 5
- Issue
- 3
- Pages
- 354-363
- ISSN
- 1876-4754 (ISSN-L)
- 1935-861X
- OpenAlex
- W1989884132
- Cited by
- 46
- References
- 5
- FWCI
- 1.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.