Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 245

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

The fade-in – Short stimulation – Fade out approach to sham tDCS – Reliable at 1 mA for naïve and experienced subjects, but not investigators

Open access
Ambrus, Géza Gergely, Al-Moyed, Hanan, Chaieb, Leila, Sarp, Lena, Antal, Andrea, Paulus, Walter·2012·Brain Stimulation

Abstract

OBJECTIVE Slowly ramping down initial current intensity after a minimal interval of stimulation is the de facto standard for sham stimulation in transcranial electrical stimulation research. The aim of this study is to further investigate the effectiveness of this method of blinding. METHODS We have investigated the time course of the cutaneous perception during 10 min of anodal, cathodal, and sham transcranial direct current stimulation, probing the perceived strength and site of the perceived sensation. We have also utilized post-stimulation assessment and measurements of sleepiness prior to and after the intervention. Previous exposure to tDCS has also been taken into account: the experiment has been repeated in naïve and experienced subject groups, and a group consisting of investigators who use tDCS as a research tool. RESULTS Although we have observed a general reduction in the perceived strength of the stimulation with time, we have not found the complete disappearance of the cutaneous perception during either the verum or the sham conditions. Experienced subjects were more likely to be able to differentiate between trials with stimulation and non-stimulation trials and to correctly identify sham and verum stimulation conditions. CONCLUSION When taking only naïve and experienced subjects into account, there was no significant difference between the strength of the perceived stimulation in the verum and sham conditions. The fade-in - short stimulation - fade-out sham stimulation can be indistinguishable from verum stimulation, but not because it mimics the disappearance of the cutaneous sensations associated with the verum stimulation, but because these sensations persist also in the sham stimulation. The significance of this finding with potential confounding factors and limitations are discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.brs.2011.12.001

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 245

Metadata

Authors
Ambrus, G. G., Al-Moyed, H., Chaieb, L., Sarp, L., Antal, A., & Paulus, W.
Venue
Brain Stimulation
Publisher
Elsevier BV
Published
2012-10
Volume
5
Issue
4
Pages
499-504
ISSN
  • 1876-4754 (ISSN-L)
  • 1935-861X
OpenAlex
W2055024290
Cited by
245
References
2
FWCI
6.34
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The fade-in – Short stimulation – Fade out approach to sham tDCS – Reliable at 1 mA for naïve and experienced subjects, but not investigators. https://app.cochat.ai/papers/10.1016/j.brs.2011.12.001
The paper
Ambrus, G. G., Al-Moyed, H., Chaieb, L., Sarp, L., Antal, A., & Paulus, W. (2012). The fade-in – Short stimulation – Fade out approach to sham tDCS – Reliable at 1 mA for naïve and experienced subjects, but not investigators. Brain Stimulation. https://doi.org/10.1016/j.brs.2011.12.001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.