The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Focused Ultrasound-mediated Non-invasive Brain Stimulation: Examination of Sonication Parameters
Open accessAbstract
Background Transcranial focused ultrasound (FUS) has emerged as a new brain stimulation modality. The range of sonication parameters for successful brain stimulation warrants further investigation. Objective The objective of this study was to examine the range of FUS sonication parameters that minimize the acoustic intensity/energy deposition while successfully stimulating the motor brain area in Sprague-Dawley rats. Methods We transcranially administered FUS to the somatomotor area of the rat brain and measured the acoustic intensity that caused excitatory effects with respect to different pulsing parameters (tone-burst duration, pulse-repetition frequency, duty cycle, and sonication duration) at 350 and 650 kHz of fundamental frequency. Results We observed that motor responses were elicited at minimum threshold acoustic intensities (4.9–5.6 W/cm2 in spatial-peak pulse-average intensity; 2.5–2.8 W/cm2 in spatial-peak temporal-average intensity) in a limited range of sonication parameters, i.e. 1–5 ms of tone-burst duration, 50% of duty cycle, and 300 ms of sonication duration, at 350 kHz fundamental frequency. We also found that the pulsed sonication elicited motor responses at lower acoustic intensities than its equivalent continuous sonication. Conclusion Our results suggest that the pulsed application of FUS selectively stimulates specific brain areas-of-interest at an acoustic intensity that is compatible with regulatory safety limits on biological tissue, thus allowing for potential applications in neurotherapeutics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Medical image analysis: progress over two decades and the challenges ahead
Duncan, J. S., & Ayache, N. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824822 · Cited by 4,140
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,476
Petilla terminology: nomenclature of features of GABAergic interneurons of the cerebral cortex
The Petilla Interneuron Nomenclature Group (PING) (2008) · Nature Reviews Neuroscience · doi:10.1038/nrn2402 · Cited by 1,491
Transcranial Pulsed Ultrasound Stimulates Intact Brain Circuits
Tufail, Y., Matyushov, A., Baldwin, N., Tauchmann, M. L., Georges, J., Yoshihiro, A., Tillery, S. I. H., & Tyler, W. J. (2010) · Neuron · doi:10.1016/j.neuron.2010.05.008 · Cited by 977
Ultrasound–biophysics mechanisms
O’Brien, W. D. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.010 · Cited by 745
Focused ultrasound modulates region-specific brain activity
Yoo, S.-S., Bystritsky, A., Lee, J.-H., Zhang, Y., Fischer, K., Min, B.-K., McDannold, N. J., Pascual-Leone, A., & Jolesz, F. A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.02.058 · Cited by 613
Self-citationMechanical Bioeffects of Ultrasound
Dalecki, D. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140126 · Cited by 564
Effective Parameters for Ultrasound-Induced In Vivo Neurostimulation
King, R. L., Brown, J. R., Newsome, W. T., & Pauly, K. B. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.09.009 · Cited by 491
Ultrasonic neuromodulation by brain stimulation with transcranial ultrasound
Tufail, Y., Yoshihiro, A., Pati, S., Li, M. M., & Tyler, W. J. (2011) · Nature Protocols · doi:10.1038/nprot.2011.371 · Cited by 473
Demonstration of Potential Noninvasive Ultrasound Brain Therapy Through an Intact Skull
Hynynen, K., & Jolesz, F. A. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00269-x · Cited by 446
Cited by
Ultrasound Neuromodulation: A Review of Results, Mechanisms and Safety
Blackmore, J., Shrivastava, S., Sallet, J., Butler, C. R., & Cleveland, R. O. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.12.015 · Cited by 556
Transcranial focused ultrasound stimulation of human primary visual cortex
Lee, W., Kim, H.-C., Jung, Y., Chung, Y. A., Song, I.-U., Lee, J.-H., & Yoo, S.-S. (2016) · Scientific Reports · doi:10.1038/srep34026 · Cited by 415
Self-citationNeuromodulation with single‐element transcranial focused ultrasound in human thalamus
Legon, W., Ai, L., Bansal, P., & Mueller, J. K. (2018) · Human Brain Mapping · doi:10.1002/hbm.23981 · Cited by 334
Non-invasive transcranial ultrasound stimulation for neuromodulation
Darmani, G., Bergmann, T. O., Butts Pauly, K., Caskey, C. F., de Lecea, L., Fomenko, A., Fouragnan, E., Legon, W., Murphy, K. R., Nandi, T., et al. (2022) · Clinical Neurophysiology · doi:10.1016/j.clinph.2021.12.010 · Cited by 332
Self-citationUltrasonic Neuromodulation Causes Widespread Cortical Activation via an Indirect Auditory Mechanism
Sato, T., Shapiro, M. G., & Tsao, D. Y. (2018) · Neuron · doi:10.1016/j.neuron.2018.05.009 · Cited by 329
Metadata
- Authors
- Kim, H., Chiu, A., Lee, S. D., Fischer, K., & Yoo, S.-S.
- Venue
- Brain Stimulation
- Publisher
- Elsevier BV
- Published
- 2014-09
- Volume
- 7
- Issue
- 5
- Pages
- 748-756
- ISSN
- 1876-4754 (ISSN-L)
- 1935-861X
- OpenAlex
- W2001096413
- Cited by
- 304
- References
- 34
- FWCI
- 5.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Focused Ultrasound-mediated Non-invasive Brain Stimulation: Examination of Sonication Parameters. https://app.cochat.ai/papers/10.1016/j.brs.2014.06.011
- The paper
- Kim, H., Chiu, A., Lee, S. D., Fischer, K., & Yoo, S.-S. (2014). Focused Ultrasound-mediated Non-invasive Brain Stimulation: Examination of Sonication Parameters. Brain Stimulation. https://doi.org/10.1016/j.brs.2014.06.011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.