Test-retest reliability of transcranial magnetic stimulation EEG evoked potentials
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
BACKGROUND Transcranial magnetic stimulation (TMS)-evoked potentials (TEPs), recorded using electroencephalography (TMS-EEG), offer a powerful tool for measuring causal interactions in the human brain. However, the test-retest reliability of TEPs, critical to their use in clinical biomarker and interventional studies, remains poorly understood. OBJECTIVE/HYPOTHESIS We quantified TEP reliability to: (i) determine the minimal TEP amplitude change which significantly exceeds that associated with simply re-testing, (ii) locate the most reliable scalp regions of interest (ROIs) and TEP peaks, and (iii) determine the minimal number of TEP pulses for achieving reliability. METHODS TEPs resulting from stimulation of the left dorsolateral prefrontal cortex were collected on two separate days in sixteen healthy participants. TEP peak amplitudes were compared between alternating trials, split-halves of the same run, two runs five minutes apart and two runs on separate days. Reliability was quantified using concordance correlation coefficient (CCC) and smallest detectable change (SDC). RESULTS Substantial concordance was achieved in prefrontal electrodes at 40 and 60 ms, centroparietal and left parietal ROIs at 100 ms, and central electrodes at 200 ms. Minimum SDC was found in the same regions and peaks, particularly for the peaks at 100 and 200 ms. CCC, but not SDC, reached optimal values by 60-100 pulses per run with saturation beyond this number, while SDC continued to improve with increased pulse numbers. CONCLUSION TEPs were robust and reliable, requiring a relatively small number of trials to achieve stability, and are thus well suited as outcomes in clinical biomarker or interventional studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785 · cited 2×
“Second, correlation between repeated TEPs is necessary but not sufficient to confirm measurement agreement; plausible scenarios could yield high Pearson correlation but low agreement, which could amplify future false positive rates [24,25].”
BackgroundMethodPower failure: why small sample size undermines the reliability of neuroscience
Button, K. S., Ioannidis, J. P. A., Mokrysz, C., Nosek, B. A., Flint, J., Robinson, E. S. J., & Munafò, M. R. (2013) · Nature Reviews Neuroscience · doi:10.1038/nrn3475 · Cited by 7,641 · cited 3×
“05 may in fact be likely to represent random chance [20].”
BackgroundInfluentialMokkink, L. B., Terwee, C. B., Patrick, D. L., Alonso, J., Stratford, P. W., Knol, D. L., Bouter, L. M., & de Vet, H. C. W. (2010) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2010.02.006 · Cited by 4,465 · cited 2×
“Reliability, meaning a test's ability to render the same value under unchanging conditions, is like validity, considered an essential feature for any clinical biomarker [14].”
BackgroundThe Existence of Publication Bias and Risk Factors for Its Occurrence
Dickersin, K. (1990) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1990.03440100097014 · Cited by 1,417 · cited 1×
“Given the space of possible parameters and the growing numbers of published results e which may only represent a fraction of attempted ones [19]e a test result whose p-value falls below 0.”
BackgroundThe role of the coil click in TMS assessed with simultaneous EEG
Nikouline, V., Ruohonen, J., & Ilmoniemi, R. J. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00070-x · Cited by 269 · cited 10×
“Maximum concordance remains substantial (>0.8) on all comparisons for the N100 and P200, with the N40 and P60 achieving substantial concordance across some of the intervals and otherwise largely remaining significant (>0.6).”
BackgroundResultInfluentialFarzan, F., Vernet, M., Shafi, M. M. D., Rotenberg, A., Daskalakis, Z. J., & Pascual-Leone, A. (2016) · Frontiers in Neural Circuits · doi:10.3389/fncir.2016.00073 · Cited by 173 · cited 1×
“Stimulation intensity was set to 120% of that session's rMT, a level used previously for both TMSevoked potentials [29,30] and clinical rTMS [31].”
Method
Cited by
Clinical utility and prospective of TMS–EEG
Tremblay, S., Rogasch, N. C., Premoli, I., Blumberger, D. M., Casarotto, S., Chen, R., Di Lazzaro, V., Farzan, F., Ferrarelli, F., Fitzgerald, P. B., et al. (2019) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.01.001 · Cited by 472
The non-transcranial TMS-evoked potential is an inherent source of ambiguity in TMS-EEG studies
Conde, V., Tomasevic, L., Akopian, I., Stanek, K., Saturnino, G. B., Thielscher, A., Bergmann, T. O., & Siebner, H. R. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.10.052 · Cited by 343
TMS combined with EEG: Recommendations and open issues for data collection and analysis
Hernandez-Pavon, J. C., Veniero, D., Bergmann, T. O., Belardinelli, P., Bortoletto, M., Casarotto, S., Casula, E. P., Farzan, F., Fecchio, M., Julkunen, P., et al. (2023) · Brain Stimulation · doi:10.1016/j.brs.2023.02.009 · Cited by 238
Transcranial magnetic stimulation: Neurophysiological and clinical applications
Burke, M. J., Fried, P. J., & Pascual-Leone, A. (2019) · Handbook of Clinical Neurology · doi:10.1016/b978-0-12-804281-6.00005-7 · Cited by 204
Disentangling EEG responses to TMS due to cortical and peripheral activations
Rocchi, L., Di Santo, A., Brown, K., Ibáñez, J., Casula, E., Rawji, V., Di Lazzaro, V., Koch, G., & Rothwell, J. (2021) · Brain Stimulation · doi:10.1016/j.brs.2020.10.011 · Cited by 199
Lenze, E. J., Nicol, G. E., Barbour, D. L., Kannampallil, T., Wong, A. W. K., Piccirillo, J., Drysdale, A. T., Sylvester, C. M., Haddad, R., Miller, J. P., et al. (2021) · Journal of Psychiatry and Neuroscience · doi:10.1503/jpn.200042 · Cited by 43
Metadata
- Authors
- Kerwin, L. J., Keller, C. J., Wu, W., Narayan, M., & Etkin, A.
- Venue
- Brain Stimulation
- Publisher
- Elsevier BV
- Published
- 2018-05
- Volume
- 11
- Issue
- 3
- Pages
- 536-544
- ISSN
- 1876-4754 (ISSN-L)
- 1935-861X
- OpenAlex
- W2776765799
- Cited by
- 145
- References
- 7
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.