CoChat

Dual threshold neural closed loop deep brain stimulation in Parkinson disease patients

Open access
Velisar, A., Syrkin-Nikolau, J., Blumenfeld, Z., Trager, M.H., Afzal, M.F., Prabhakar, V., Bronte-Stewart, H. · 2019 · Brain Stimulation
Cited by 252

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Abstract

BACKGROUND Closed loop deep brain stimulation (clDBS) in Parkinson's disease (PD) using subthalamic (STN) neural feedback has been shown to be efficacious only in the acute post-operative setting, using externalized leads and stimulators. OBJECTIVE To determine feasibility of neural (N)clDBS using the clinical implanted neurostimulator (Activa™ PC + S, FDA IDE approved) and a novel beta dual threshold algorithm in tremor and bradykinesia dominant PD patients on chronic DBS. METHODS 13 PD subjects (20 STNs), on open loop (ol)DBS for 22 ± 7.8 months, consented to NclDBS driven by beta (13-30 Hz) power using a dual threshold algorithm, based on patient specific therapeutic voltage windows. Tremor was assessed continuously, and bradykinesia was evaluated after 20 min of NclDBS using a repetitive wrist flexion-extension task (rWFE). Total electrical energy delivered (TEED) on NclDBS was compared to olDBS using the same active electrode. RESULTS NclDBS was tolerated for 21.67 [21.10-26.15] minutes; no subject stopped early. Resting beta band power was measurable and similar between tremor and bradykinesia dominant patients. NclDBS improved bradykinesia and tremor while delivering only 56.86% of the TEED of olDBS; rWFE velocity (p = 0.003) and frequency (p < 0.001) increased; tremor was below 0.15 rad/sec for 95.4% of the trial and averaged 0.26 rad/sec when present. CONCLUSION This is the first study to demonstrate that STN NclDBS is feasible, efficacious and more efficient than olDBS in tremor and bradykinesia dominant PD patients, on long-term DBS, using an implanted clinical neurostimulator and driven by beta power with a novel dual threshold algorithm, based on customized therapeutic voltage windows.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.brs.2019.02.020

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 252

Metadata

Authors
Velisar, A., Syrkin-Nikolau, J., Blumenfeld, Z., Trager, M. H., Afzal, M. F., Prabhakar, V., & Bronte-Stewart, H.
Venue
Brain Stimulation
Publisher
Elsevier BV
Published
2019-07
Volume
12
Issue
4
Pages
868-876
ISSN
  • 1876-4754 (ISSN-L)
  • 1935-861X
OpenAlex
W2917762754
Cited by
252
References
29
FWCI
17.29
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.