CoChat

A lightweight CNN for Diabetic Retinopathy classification from fundus images

S., Gayathri, Gopi, Varun P., Palanisamy, P. · 2020 · Biomedical Signal Processing and Control
Cited by 210

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

Abstract

Abstract Diabetic Retinopathy (DR) is a complication of diabetes mellitus that damages blood vessel networks in the retina. This is a serious vision-threatening issue in most diabetic subjects. The DR diagnosis by color fundus images involves skilled clinicians to recognize the presence of lesions in the image that can be used to detect the disease properly, making it a time-consuming process. Effective automated detection of DR is a challenging task. The feature extraction plays an excellent role in effective automated disease detection. Convolutional Neural Networks (CNN) have superior image classification efficiency in the present scenario compared to earlier handcrafted feature-based image classification techniques. This work presents a novel CNN model to extract features from retinal fundus images for better classification performance. The CNN output features are used as input for different machine learning classifiers in the suggested system. The model is evaluated through various classifiers (Support Vector Machine, AdaBoost, Naive Bayes, Random Forest, and J48) by using images from generic IDRiD, MESSIDOR, and KAGGLE datasets. The efficacy of the classifier is evaluated by comparing the specificity, precision, recall, False Positive Rate (FPR), Kappa-score, and accuracy values for each classifier. The evaluation results indicate that the proposed feature extraction technique along with the J48 classifier outperforms all the other classifiers for MESSIDOR, IDRiD, and KAGGLE datasets with an average accuracy of 99.89% for binary classification and 99.59% for multiclass classification. Furthermore, for the J48 classifier, the average Kappa-score (K-score) is 0.994 for binary classification and 0.994 for multi-class classification.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bspc.2020.102115

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 37 references

Metadata

Authors
S., G., Gopi, V. P., & Palanisamy, P.
Venue
Biomedical Signal Processing and Control
Publisher
Elsevier BV
Published
2020-09
Volume
62
Pages
102115
ISSN
1746-8094 (ISSN-L)
OpenAlex
W3048817311
Cited by
210
References
37
FWCI
14.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A lightweight CNN for Diabetic Retinopathy classification from fundus images. https://app.cochat.ai/papers/10.1016/j.bspc.2020.102115
The paper
S., G., Gopi, V. P., & Palanisamy, P. (2020). A lightweight CNN for Diabetic Retinopathy classification from fundus images. Biomedical Signal Processing and Control. https://doi.org/10.1016/j.bspc.2020.102115

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.