CoChat

Optimal design method for building energy systems using genetic algorithms

Ooka, Ryozo, Komamura, Kazuhiko · 2009 · Building and Environment
Cited by 122

The DOI matches its Crossref record.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.buildenv.2008.07.006

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 11

  1. Sundberg, 2002, Investments in combined heat and power plants: influence of fuel price on cost minimized operation, Energy Conversion and Management, 43, 639, 10.1016/S0196-8904(01)00065-6 · doi:10.1016/s0196-8904(01)00065-6
  2. Henning, 1997, MODEST – an energy system optimisation model applicable to local utilities and countries, Energy, 22, 1135, 10.1016/S0360-5442(97)00052-2 · doi:10.1016/s0360-5442(97)00052-2
  3. Write, 1987, The formulation, characteristics, and solution of HVAC system optimized design problems, ASHRAE Transaction, 93, 2133
  4. Huang, 1997, Using genetic algorithms to optimize controller parameters for HVAC systems, Energy and Buildings, 26, 277, 10.1016/S0378-7788(97)00008-X · DOI · Paper page
  5. Fong, 2006, HVAC system optimization for energy management by evolutionary programming, Energy and Buildings, 38, 220, 10.1016/j.enbuild.2005.05.008 · DOI · Paper page
  6. Obara, 2003, Multiple-purpose operational planning of fuel cell and heat pump compound system using genetic algorithm, Transaction of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan, 91, 65
  7. Wright, 2002, Optimization of building thermal design and control by multi-criterion genetic algorithm, Energy and Buildings, 34, 959, 10.1016/S0378-7788(02)00071-3 · DOI
  8. Hong Chen, Ryozo Ooka, Shinsuke Kato. Study on optimum arrangement of pilotis for design of pleasant outdoor wind environment using CFD simulation and Genetic Algorithms (GA), The Sixth Asia-Pacific Conference on Wind Engineering (APCWE-VI); 2005.
  9. Li, 2006, Thermal-economic optimization of a distributed multi-generation energy system – a case study of Beijing, Applied Thermal Engineering, 26, 709, 10.1016/j.applthermaleng.2005.09.005 · doi:10.1016/j.applthermaleng.2005.09.005
  10. Tanese, 1989, Distributed genetic algorithms, Proceedings of Third ICGA, 434
  11. Hong Chen, Ryozo Ooka, Shinsuke Kato. Study on optimum design method for pleasant outdoor thermal environment using genetic algorithms (GA) and coupled simulation of convection, radiation and conduction. Fourth International Symposium on New Technologies for Urban Safety of Mega Cities in Asia (USMCA 2005), 2005.

Cited by

Metadata

Authors
Ooka, R., & Komamura, K.
Venue
Building and Environment
Publisher
Elsevier BV
Published
2009-07
Volume
44
Issue
7
Pages
1538-1544
ISSN
0360-1323
Cited by
122
References
0
Language
en
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.