The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Indoor environmental quality assessment models: A literature review and a proposed weighting and classification scheme
Open accessAbstract
This paper explores the existing literature on indoor environmental quality (IEQ) evaluation models and proposes a new weighting and classification scheme. Studies that attempt to provide IEQ assessment of commercial buildings through a scoring system are reviewed and critiqued. Objective and subjective evaluation methods and correlations are discussed. The use of assessment categories (classes) in IEQ models is critiqued and an argument is proposed against their adoption. IEQ weighting schemes are summarized and compared against a newly developed scheme based on 52,980 occupant responses in office buildings. A binary assessment classification scheme is proposed in alignment with the ASHRAE/CIBSE/USGBC Performance Measurement Protocols for Commercial Buildings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal Environmental Conditions for Human Occupancy
Ashrae, S. (1992) · Medical Entomology and Zoology · Cited by 6,092
Jones, A. P. (1999) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00272-1 · Cited by 1,481
Thermal comfort in naturally ventilated buildings: revisions to ASHRAE Standard 55
de Dear, R. J., & Brager, G. S. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00005-1 · Cited by 1,438
Literature survey on how different factors influence human comfort in indoor environments
Frontczak, M., & Wargocki, P. (2011) · Building and Environment · doi:10.1016/j.buildenv.2010.10.021 · Cited by 1,248
WARGOCKI, P., WYON, D. P., SUNDELL, J., CLAUSEN, G., & FANGER, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004222.x · Cited by 688
Frontczak, M., Schiavon, S., Goins, J., Arens, E., Zhang, H., & Wargocki, P. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2011.00745.x · Cited by 562
Self-citationFisk, W. J. (2000) · Annual Review of Energy and the Environment · doi:10.1146/annurev.energy.25.1.537 · Cited by 557
Impact of Temperature and Humidity on the Perception of Indoor Air Quality
Fang, L., Clausen, G., & Fanger, P. O. (1998) · Indoor Air · doi:10.1111/j.1600-0668.1998.t01-2-00003.x · Cited by 534
Multiple surveys of students and survey fatigue
Porter, S. R., Whitcomb, M. E., & Weitzer, W. H. (2004) · New Directions for Institutional Research · doi:10.1002/ir.101 · Cited by 533
The Oxford Dictionary of Statistical Terms
(2004) · Technometrics · doi:10.1198/tech.2004.s820 · Cited by 448
Cited by
Influence of indoor environmental quality on human health and productivity - A review
Mujan, I., Anđelković, A. S., Munćan, V., Kljajić, M., & Ružić, D. (2019) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.01.307 · Cited by 405
Post-occupancy evaluation: State-of-the-art analysis and state-of-the-practice review
Li, P., Froese, T. M., & Brager, G. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.02.024 · Cited by 343
Geng, Y., Ji, W., Wang, Z., Lin, B., & Zhu, Y. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2018.11.017 · Cited by 324
Ali, A. S., Coté, C., Heidarinejad, M., & Stephens, B. (2019) · Sensors · doi:10.3390/s19184017 · Cited by 50
Metadata
- Authors
- Heinzerling, D., Schiavon, S., Webster, T., & Arens, E.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2013-12
- Volume
- 70
- Pages
- 210-222
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W2052506965
- Cited by
- 308
- References
- 35
- FWCI
- 17.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Indoor environmental quality assessment models: A literature review and a proposed weighting and classification scheme. https://app.cochat.ai/papers/10.1016/j.buildenv.2013.08.027
- The paper
- Heinzerling, D., Schiavon, S., Webster, T., & Arens, E. (2013). Indoor environmental quality assessment models: A literature review and a proposed weighting and classification scheme. Building and Environment. https://doi.org/10.1016/j.buildenv.2013.08.027
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.