Extending air temperature setpoints: Simulated energy savings and design considerations for new and retrofit buildings

Open access
Hoyt, Tyler, Arens, Edward, Zhang, Hui·2015·Building and Environment

Integrity signals

Registry

Crossref · 10.1016/j.buildenv.2014.09.010

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Total HVAC energy use can be reduced at a rate of 10% per K room temperature setpoint relaxation when using personalized heating, ventilation, or cooling.

    “Since it is possible to relax the room temperature range in either the hot or cold direction due to the use of personalized heating, ventilation or cooling, total HVAC energy use can be reduced at a rate of 10% per K room temperature setpoint relaxation [248,249].”

Cited by

Sorted by citations

Authors
Hoyt, T., Arens, E., & Zhang, H.
Affiliations
University of California, Berkeley (US)
Corresponding author
Hoyt, Tyler
Venue
Building and Environment
Publisher
Elsevier BV
Published
2015-06
Volume
88
Pages
89-96
ISSN
0360-1323 (ISSN-L)
OpenAlex
W2138854094
Cited by
607
References
0
Citations by year
2026: 58 · 2025: 67 · 2024: 65 · 2023: 77 · 2022: 67 · 2021: 46 · 2020: 50 · 2019: 55 · 2018: 47 · 2017: 40 · 2016: 21 · 2015: 12 · 2014: 2
FWCI
34.57
Type
journal article
Language
en
Open access
Locations
  • Building and Environment (publishedVersion)
  • eScholarship (California Digital Library) (submittedVersion)
Funders
  • California Energy Commission (PIR-12-026)
  • California EPA Air Resources Board (10308)
  • Center for the Built Environment
Topics
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
  • Physical Sciences › Engineering › Building and Construction › Building energy efficiency and sustainability
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
Keywords
thermostat setpoints, dead band, HVAC energy savings, office buildings, occupant thermal comfort, ASHRAE climate zones, building energy simulation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review