Extending air temperature setpoints: Simulated energy savings and design considerations for new and retrofit buildings
Open accessIntegrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Total HVAC energy use can be reduced at a rate of 10% per K room temperature setpoint relaxation when using personalized heating, ventilation, or cooling.
“Since it is possible to relax the room temperature range in either the hot or cold direction due to the use of personalized heating, ventilation or cooling, total HVAC energy use can be reduced at a rate of 10% per K room temperature setpoint relaxation [248,249].”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [248]
Cited by
Sorted by citations
Individual difference in thermal comfort: A literature review
Wang, Z., de Dear, R., Luo, M., Lin, B., He, Y., Ghahramani, A., & Zhu, Y. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.04.040 · Cited by 675 · see citing works
Thermal pleasure in built environments: physiology of alliesthesia
Parkinson, T., & de Dear, R. (2015) · Building Research & Information · doi:10.1080/09613218.2015.989662 · Cited by 263 · see citing works
Resilient cooling strategies – A critical review and qualitative assessment
Zhang, C., Kazanci, O. B., Levinson, R., Heiselberg, P., Olesen, B. W., Chiesa, G., Sodagar, B., Ai, Z., Selkowitz, S., Zinzi, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111312 · Cited by 180 · see citing works
Self-citation
- Authors
- Hoyt, T., Arens, E., & Zhang, H.
- Affiliations
- University of California, Berkeley (US)
- Corresponding author
- Hoyt, Tyler
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2015-06
- Volume
- 88
- Pages
- 89-96
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W2138854094
- Cited by
- 607
- References
- 0
- Citations by year
- 2026: 58 · 2025: 67 · 2024: 65 · 2023: 77 · 2022: 67 · 2021: 46 · 2020: 50 · 2019: 55 · 2018: 47 · 2017: 40 · 2016: 21 · 2015: 12 · 2014: 2
- FWCI
- 34.57
- Type
- journal article
- Language
- en
- Open access
- green
- www.escholarship.org
- Locations
- Building and Environment (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Funders
- California Energy Commission (PIR-12-026)
- California EPA Air Resources Board (10308)
- Center for the Built Environment
- Topics
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Engineering › Building and Construction › Building energy efficiency and sustainability
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Keywords
- thermostat setpoints, dead band, HVAC energy savings, office buildings, occupant thermal comfort, ASHRAE climate zones, building energy simulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review