Smart lighting system using ANN-IMC for personalized lighting control and daylight harvesting
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Lighting contributes a significant portion to the overall energy consumption in an office building. It is thus important to reduce the energy consumption of lighting systems especially for Net Zero Energy Buildings (NZEB). Maximizing daylight harvesting can significantly increase the energy savings. With increase in demand for satisfying occupant preferences in visual comfort, the need for personalized lighting in the office space is also rising. In this paper, a novel lighting control system for Net Zero Energy Buildings (NZEB) is proposed which models the lighting system using Artificial Neural Network (ANN) and utilizes this model with the Internal Model Control (IMC) principle for controller design . Modeling the lighting system using ANN reduces the challenge of modeling a large and complex system with inherent process variability without the need to analyze extensive data-sets. The proposed ANN-IMC controller uses feedback from sensors on the task table to maintain desired illuminance , is easy to tune with just one parameter and is robust to process variability. The proposed control design is applicable to square systems where the number of lights and number of sensors are equal. However, the proposed architecture can also be extended for controlling other lighting accessories such as roller blinds. The performance of the proposed lighting control system to harvest the daylight effectively is demonstrated using both simulation results and an experimental setup in test-bed environment. The versatility of the proposed system will allow an operator to deploy personalized lighting in an office space.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review of simulation modeling for shading devices in buildings
Kirimtat, A., Koyunbaba, B. K., Chatzikonstantinou, I., & Sariyildiz, S. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.08.020 · Cited by 351 · cited 1×
“A comprehensive review on ’Dynamic operation of daylighting and shading systems’ was presented in [34] and a comprehensive review on different type of shading devices and type of studies used for analysis (simulation or experimental or both) was presented in [35, 36].”
Intelligent system for lighting control in smart cities
De Paz, J. F., Bajo, J., Rodríguez, S., Villarrubia, G., & Corchado, J. M. (2016) · Information Sciences · doi:10.1016/j.ins.2016.08.045 · Cited by 146
Sensor-driven, human-in-the-loop lighting control
Tan, F., Caicedo, D., Pandharipande, A., & Zuniga, M. (2018) · Lighting Research & Technology · doi:10.1177/1477153517693887 · Cited by 33
Cited by
Modeling and forecasting building energy consumption: A review of data-driven techniques
Bourdeau, M., Zhai, X. Q., Nefzaoui, E., Guo, X., & Chatellier, P. (2019) · Sustainable Cities and Society · doi:10.1016/j.scs.2019.101533 · Cited by 792
Park, J. Y., Dougherty, T., Fritz, H., & Nagy, Z. (2019) · Building and Environment · doi:10.1016/j.buildenv.2018.10.028 · Cited by 238
Machine Learning Methods in Smart Lighting Toward Achieving User Comfort: A Survey
Putrada, A. G., Abdurohman, M., Perdana, D., & Nuha, H. H. (2022) · IEEE Access · doi:10.1109/access.2022.3169765 · Cited by 101
Energy saving potential through artificial lighting system in PV integrated smart buildings
Shankar, A., Vijayakumar, K., & Babu, B. C. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2021.103080 · Cited by 47
An Improvement of Led Lighting System Accuracy with Voltage Control System
Abdurohman, M., Nugraha, R., & Gautama Putrada, A. (2020) · 2020 Fifth International Conference on Informatics and Computing (ICIC) · doi:10.1109/icic50835.2020.9288576 · Cited by 7
“In a 2018 study, energy-saving smart lighting was carried out using the ANNIMC method [5].”
Method
Metadata
- Authors
- Kandasamy, N. K., Karunagaran, G., Spanos, C., Tseng, K. J., & Soong, B.-H.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2018-07
- Volume
- 139
- Pages
- 170-180
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W2803487351
- Cited by
- 128
- References
- 3
- FWCI
- 10.95
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.