The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Analysis of the accuracy on PMV – PPD model using the ASHRAE Global Thermal Comfort Database II
Open accessAbstract
The predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD) are the most widely used thermal comfort indices. Yet, their performance remains a contested topic. The ASHRAE Global Thermal Comfort Database II, the largest of its kind, was used to evaluate the prediction accuracy of the PMV/PPD model. We focused on: (i) the accuracy of PMV in predicting both observed thermal sensation (OTS) or observed mean vote (OMV) and (ii) comparing the PMV-PPD relationship with binned OTS – observed percentage of unacceptability (OPU). The accuracy of PMV in predicting OTS was only 34%, meaning that the thermal sensation is incorrectly predicted two out of three times. PMV had a mean absolute error of one unit on the thermal sensation scale and its accuracy decreased towards the ends of the thermal sensation scale. The accuracy of PMV was similarly low for air-conditioned, naturally ventilated and mixed-mode buildings. In addition, the PPD was not able to predict the dissatisfaction rate. If the PMV model would perfectly predict thermal sensation, then PPD accuracy is higher close to neutrality but it would overestimate dissatisfaction by approximately 15–25% outside of it. Furthermore, PMV-PPD accuracy varied strongly between ventilation strategies, building types and climate groups. These findings demonstrate the low prediction accuracy of the PMV–PPD model, indicating the need to develop high prediction accuracy thermal comfort models. For demonstration, we developed a simple thermal prediction model just based on air temperature and its accuracy, for this database, was higher than PMV.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
World map of the Köppen-Geiger climate classification updated
Kottek, M., Grieser, J., Beck, C., Rudolf, B., & Rubel, F. (2006) · Meteorologische Zeitschrift · doi:10.1127/0941-2948/2006/0130 · Cited by 11,456
Thermal comfort: Analysis and applications in environmental engineering
(1972) · Applied Ergonomics · doi:10.1016/s0003-6870(72)80074-7 · Cited by 4,451
Nonparametrics: Statistical Methods Based on Ranks
Mergenthaler, M. J., & Lehmann, E. L. (1979) · Technometrics · doi:10.2307/1268531 · Cited by 3,329
Nonparametrics: Statistical Methods Based on Ranks.
Beaver, R. J., & Lehmann, E. L. (1976) · Biometrics · doi:10.2307/2529529 · Cited by 2,047
(1998) · eScholarship (California Digital Library) · Cited by 1,934
Thermal adaptation in the built environment: a literature review
Brager, G. S., & de Dear, R. J. (1998) · Energy and Buildings · doi:10.1016/s0378-7788(97)00053-4 · Cited by 1,483
Self-citationA review of human thermal comfort in the built environment
Rupp, R. F., Vásquez, N. G., & Lamberts, R. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.07.047 · Cited by 907
Extension of the PMV model to non-air-conditioned buildings in warm climates
Ole Fanger, P., & Toftum, J. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00003-8 · Cited by 853
Forty years of Fanger’s model of thermal comfort: comfort for all?
van Hoof, J. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2007.00516.x · Cited by 733
The validity of ISO-PMV for predicting comfort votes in every-day thermal environments
Humphreys, M. A., & Fergus Nicol, J. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00018-x · Cited by 709
Kim, J., Schiavon, S., & Brager, G. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.01.023 · Cited by 522
Self-citationDevelopment of the ASHRAE Global Thermal Comfort Database II
Földváry Ličina, V., Cheung, T., Zhang, H., de Dear, R., Parkinson, T., Arens, E., Chun, C., Schiavon, S., Luo, M., Brager, G., et al. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.06.022 · Cited by 481
Self-citationKim, J., Zhou, Y., Schiavon, S., Raftery, P., & Brager, G. (2018) · Building and Environment · doi:10.1016/j.buildenv.2017.12.011 · Cited by 478
Self-citationOutdoor temperatures and comfort indoors
Humphreys, M. (1978) · Batiment International, Building Research and Practice · doi:10.1080/09613217808550656 · Cited by 377
Thermal comfort for naturally ventilated houses in Indonesia
Feriadi, H., & Wong, N. H. (2004) · Energy and Buildings · doi:10.1016/j.enbuild.2004.01.011 · Cited by 367
Thermal comfort in classrooms in the tropics
Wong, N. H., & Khoo, S. S. (2003) · Energy and Buildings · doi:10.1016/s0378-7788(02)00109-3 · Cited by 356
Field studies on human thermal comfort — An overview
Mishra, A. K., & Ramgopal, M. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.02.015 · Cited by 336
Thermal comfort as part of a self-regulating system
Nicol, J. F., & Humphreys, M. A. (1973) · Building Research and Practice · doi:10.1080/09613217308550237 · Cited by 287
Teli, D., Jentsch, M. F., & James, P. A. B. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.06.022 · Cited by 284
Field Studies of Indoor Thermal Comfort and the Progress of the Adaptive Approach
Humphreys, M. A., Nicol, J. F., & Raja, I. A. (2007) · Advances in Building Energy Research · doi:10.1080/17512549.2007.9687269 · Cited by 249
Thermal comfort in naturally ventilated buildings in hot-humid area of China
Zhang, Y., Wang, J., Chen, H., Zhang, J., & Meng, Q. (2010) · Building and Environment · doi:10.1016/j.buildenv.2010.05.024 · Cited by 216
Energy saving and improved comfort by increased air movement
Schiavon, S., & Melikov, A. K. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2008.05.001 · Cited by 213
Self-citationSchellen, L., Loomans, M. G. L. C., de Wit, M. H., Olesen, B. W., & Lichtenbelt, W. D. V. M. (2012) · Physiology & Behavior · doi:10.1016/j.physbeh.2012.07.008 · Cited by 206
Hwang, R.-L., Cheng, M.-J., Lin, T.-P., & Ho, M.-C. (2009) · Building and Environment · doi:10.1016/j.buildenv.2008.08.001 · Cited by 186
Kim, J., & de Dear, R. (2018) · Building and Environment · doi:10.1016/j.buildenv.2017.10.031 · Cited by 177
PMV–PPD and acceptability in naturally ventilated schools
d'Ambrosio Alfano, F. R., Ianniello, E., & Palella, B. I. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.05.013 · Cited by 172
Thermal comfort: research and practice
Hoof, J. V. (2010) · Frontiers in Bioscience · doi:10.2741/3645 · Cited by 171
Predicted and reported thermal sensation in climate chambers, offices and homes
Oseland, N. A. (1995) · Energy and Buildings · doi:10.1016/0378-7788(95)00934-5 · Cited by 161
Thermal comfort in residential buildings – Failure to predict by Standard model
Becker, R., & Paciuk, M. (2009) · Building and Environment · doi:10.1016/j.buildenv.2008.06.011 · Cited by 158
International standards for the indoor environment
Olesen, B. W. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00268.x · Cited by 154
Residential adaptive comfort in a humid subtropical climate—Sydney Australia
de Dear, R., Kim, J., & Parkinson, T. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.11.028 · Cited by 132
Self-citationEVALUATION OF THE PHYSIOLOGICAL BASES OF THERMAL COMFORT MODELS
Doherty, T. J. (1988) · eScholarship (California Digital Library) · Cited by 117
Rupp, R. F., de Dear, R., & Ghisi, E. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.11.047 · Cited by 115
A study of adaptive thermal comfort in a well-controlled climate chamber
Yang, Y., Li, B., Liu, H., Tan, M., & Yao, R. (2014) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2014.11.004 · Cited by 105
Gao, J., Wang, Y., & Wargocki, P. L. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.04.030 · Cited by 102
Humphreys, & Nicol, F. (2000) · Cited by 97
Study on adaptive thermal comfort in Japanese offices under various operation modes
Takasu, M., Ooka, R., Rijal, H. B., et al. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.02.023 · Cited by 87
PMV model is insufficient to capture subjective thermal response from Indians
Maiti, R. (2014) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2014.01.005 · Cited by 77
Thermal acceptability assessment in buildings located in hot and humid regions in Brazil
Andreasi, W. A., Lamberts, R., & Cândido, C. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.11.005 · Cited by 49
Bayesian thermal comfort model
Wong, L. T., Mui, K. W., & Cheung, T. C. T. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.08.018 · Cited by 34
Self-citation
Cited by
Personal thermal comfort models with wearable sensors
Liu, S., Schiavon, S., Das, H. P., Jin, M., & Spanos, C. J. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106281 · Cited by 306
Self-citationTen questions concerning well-being in the built environment
Altomonte, S., Allen, J., Bluyssen, P. M., Brager, G., Heschong, L., Loder, A., Schiavon, S., Veitch, J. A., Wang, L., & Wargocki, P. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106949 · Cited by 303
Self-citationNgarambe, J., Yun, G. Y., & Santamouris, M. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.109807 · Cited by 261
Revisiting individual and group differences in thermal comfort based on ASHRAE database
Wang, Z., Zhang, H., He, Y., Luo, M., Li, Z., Hong, T., & Lin, B. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110017 · Cited by 123
Machine Learning for Smart and Energy-Efficient Buildings
Das, H. P., Lin, Y.-W., Agwan, U., Spangher, L., Devonport, A., Yang, Y., Drgoňa, J., Chong, A., Schiavon, S., & Spanos, C. J. (2024) · Environmental Data Science · doi:10.1017/eds.2023.43 · Cited by 78
Self-citation
Metadata
- Authors
- Cheung, T., Schiavon, S., Parkinson, T., Li, P., & Brager, G.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2019-04
- Volume
- 153
- Pages
- 205-217
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W2913198854
- Cited by
- 566
- References
- 40
- FWCI
- 32.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.