CoChat

A comparative study of predicting individual thermal sensation and satisfaction using wrist-worn temperature sensor, thermal camera and ambient temperature sensor

Open access
Aryal, Ashrant, Becerik-Gerber, Burcin · 2019 · Building and Environment
Cited by 160

The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.

Abstract

Abstract Recent advancements in Internet of Things and Machine Learning have opened the possibility of deploying sensors at a large scale to monitor the environment and to model and predict thermal comfort at an individual level. There has been a growing interest to use physiological information obtained from wearable devices or thermal imaging to improve individual thermal comfort prediction. In this study, we compared the accuracies of using environmental sensing with an air temperature sensor, physiological sensing with a wrist-worn device to monitor wrist skin temperature or thermal camera to monitor facial skin temperatures for predicting individual thermal sensation and satisfaction. The experiment was conducted in a controlled environment without any radiant heat sources or local comfort devices; solely the air temperature was changed. For the conditions studied, our results indicate that using data from an environmental sensor for predicting thermal comfort results in a higher accuracy compared to using physiological sensors (either wearable device or thermal camera) alone. Combining data from both environmental and physiological sensors leads to about 3%–4% higher accuracy than using environmental sensors only. Slight improvement in accuracy from the physiological sensors might not be sufficient to justify the privacy concerns and additional costs of using physiological sensors at a large scale for predicting thermal comfort in environments without radiant heat sources or local comfort devices. Future studies under different environmental conditions with a larger population are needed to better understand the tradeoffs between different sensing methods for predicting thermal comfort at an individual level.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.buildenv.2019.106223

Cites

58 of 58 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 58 references

Cited by

See all 160

Metadata

Authors
Aryal, A., & Becerik-Gerber, B.
Venue
Building and Environment
Publisher
Elsevier BV
Published
2019-08
Volume
160
Pages
106223
ISSN
0360-1323 (ISSN-L)
OpenAlex
W2951576731
Cited by
160
References
58
FWCI
10.85
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A comparative study of predicting individual thermal sensation and satisfaction using wrist-worn temperature sensor, thermal camera and ambient temperature sensor. https://app.cochat.ai/papers/10.1016/j.buildenv.2019.106223
The paper
Aryal, A., & Becerik-Gerber, B. (2019). A comparative study of predicting individual thermal sensation and satisfaction using wrist-worn temperature sensor, thermal camera and ambient temperature sensor. Building and Environment. https://doi.org/10.1016/j.buildenv.2019.106223

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.