CoChat

Generative adversarial network for fault detection diagnosis of chillers

Yan, Ke, Chong, Adrian, Mo, Yuchang · 2020 · Building and Environment
Cited by 212

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Abstract Automatic fault detection and diagnosis (AFDD) for chillers has significant impacts on energy saving, indoor environment comfort and systematic building management. Recent works show that the artificial intelligence (AI) enhanced techniques outperform most of the traditional fault detection and diagnosis methods. However, one serious issue has been raised in recent studies, which shows that insufficient number of fault training samples in the training phase of AI techniques can significantly influence the final classification accuracy. The insufficient number of fault samples refers to the imbalanced-class classification problem, which is a hot topic in the field of machine learning. In this study, we re-visit the imbalanced-class problem for fault detection and diagnosis of chiller in the heating, ventilation and air-conditioning (HVAC) system. The generative adversarial network is employed and customized to re-balance the training dataset for chiller AFDD. Experimental results demonstrate the effectiveness of the proposed GAN-integrated framework compared with traditional chiller AFDD methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.buildenv.2020.106698

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 212

Metadata

Authors
Yan, K., Chong, A., & Mo, Y.
Venue
Building and Environment
Publisher
Elsevier BV
Published
2020-04
Volume
172
Pages
106698
ISSN
0360-1323 (ISSN-L)
OpenAlex
W3002783982
Cited by
212
References
4
FWCI
15.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.