Nexus of thermal resilience and energy efficiency in buildings: A case study of a nursing home
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Abstract Extreme weather events become more frequent and severe due to climate change. Although energy efficiency technologies can influence thermal resilience of buildings, they are traditionally studied separately, and their interconnections are rarely quantified. This study developed a methodology of modeling and analysis to provide insights into the nexus of thermal resilience and energy efficiency of buildings. We conducted a case study of a real nursing home in Florida, where 12 patients died during Hurricane Irma in 2017 due to HVAC system power loss, to understand and quantify how passive and active energy efficiency measures (EEMs) can improve thermal resilience to reduce heat-exposure risk of patients. Results show that passive measures of opening windows and doors for natural ventilation, as well as miscellaneous load reduction, are very effective in eliminating the extreme dangerous occasions. However, to maintain safe conditions, active measures such as on-site power generators and thermal storage are also needed. The nursing home was further studied by changing its location to two other cities: San Francisco (mild climate) and Chicago (cold winter and hot summer). Results revealed that the EEMs' impacts on thermal resilience vary significantly by climate and building characteristics. The study also estimated the costs of EEMs to help stakeholders prioritize the measures. Passive measures that may not save energy may greatly improve thermal resilience, and thus should be considered in building design or retrofit. Findings from this study indicate energy efficiency technologies should be evaluated not only by their energy savings performance but also by their influence on a building's resilience to extreme weather events.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Death toll exceeded 70,000 in Europe during the summer of 2003
Robine, J.-M., Cheung, S. L. K., Le Roy, S., Van Oyen, H., Griffiths, C., Michel, J.-P., & Herrmann, F. R. (2007) · Comptes Rendus. Biologies · doi:10.1016/j.crvi.2007.12.001 · Cited by 2,127
The Hot Summer of 2010: Redrawing the Temperature Record Map of Europe
Barriopedro, D., Fischer, E. M., Luterbacher, J., Trigo, R. M., & García-Herrera, R. (2011) · Science · doi:10.1126/science.1201224 · Cited by 1,656 · cited 1×
“A Russian heatwave in 2010 was responsible for up to 56,000 deaths [5], while a 1995 Chicago heatwave led to more than 600 casualties and 3,300 emergency room visits [6].”
Climate change, mortality, and adaptation: Evidence from annual fluctuations in weather in the US
Deschênes, O., & Greenstone, M. (2011) · American Economic Journal: Applied Economics · doi:10.1257/app.3.4.152 · Cited by 1,064
Wet-bulb globe temperature (WBGT)—its history and its limitations
Budd, G. M. (2008) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2007.07.003 · Cited by 783
Impact of climate change heating and cooling energy use in buildings in the United States
Wang, H., & Chen, Q. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.07.034 · Cited by 364
Optimal decarbonization pathways for urban residential building energy services
Leibowicz, B. D., Lanham, C. M., Brozynski, M. T., Vázquez-Canteli, J. R., Castejón, N. C., & Nagy, Z. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.09.046 · Cited by 142
Suicide risk in long-term care facilities: a systematic review
Mezuk, B., Rock, A., Lohman, M. C., & Choi, M. (2014) · International Journal of Geriatric Psychiatry · doi:10.1002/gps.4142 · Cited by 95 · cited 1×
“People are often instructed to close the windows to avoid cooling leakage when the AC is on [127]; and (2) For security purposes, windows may be locked to avoid suicide [128,129].”
BackgroundLo, Y. T. E., Mitchell, D. M., Gasparrini, A., Vicedo-Cabrera, A. M., Ebi, K. L., Frumhoff, P. C., Millar, R. J., Roberts, W., Sera, F., Sparrow, S., et al. (2019) · Science Advances · doi:10.1126/sciadv.aau4373 · Cited by 70
Cited by
Attia, S., Levinson, R., Ndongo, E., Holzer, P., Berk Kazanci, O., Homaei, S., Zhang, C., Olesen, B. W., Qi, D., Hamdy, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.110869 · Cited by 208
Ten questions concerning thermal resilience of buildings and occupants for climate adaptation
Hong, T., Malik, J., Krelling, A., O'Brien, W., Sun, K., Lamberts, R., & Wei, M. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110806 · Cited by 159
Self-citationSheng, M., Reiner, M., Sun, K., & Hong, T. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110001 · Cited by 112
Self-citationSun, K., Zhang, W., Zeng, Z., Levinson, R., Wei, M., & Hong, T. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111383 · Cited by 86
Self-citationRahif, R., Kazemi, M., & Attia, S. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.112998 · Cited by 51
Metadata
- Authors
- Sun, K., Specian, M., & Hong, T.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2020-06
- Volume
- 177
- Pages
- 106842
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W3016613541
- Cited by
- 126
- References
- 8
- FWCI
- 6.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nexus of thermal resilience and energy efficiency in buildings: A case study of a nursing home. https://app.cochat.ai/papers/10.1016/j.buildenv.2020.106842
- The paper
- Sun, K., Specian, M., & Hong, T. (2020). Nexus of thermal resilience and energy efficiency in buildings: A case study of a nursing home. Building and Environment. https://doi.org/10.1016/j.buildenv.2020.106842
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.