The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Learning-based CO2 concentration prediction: Application to indoor air quality control using demand-controlled ventilation
Open accessAbstract
There have been increasing concerns over the air quality inside buildings as high levels of bio-effluents can cause nausea, dizziness, headaches, and fatigue to the people working in those spaces. First published in 2004 as Standard 62.1, ASHRAE Standard 62.2-2019 requires highly occupied spaces to implement heating, ventilation, and air conditioning (HVAC) that can dilute contaminants produced by occupants. In this regard, occupant-centric ventilation control has been regarded as an effective practice to maintain a satisfactory indoor air quality (IAQ) when dealing with highly variable occupancy environments. However, few established models in current literature and practice consider dynamic occupancy behavior and adaptive IAQ control. To address this gap, a dynamic indoor CO2 model is constructed using machine learning algorithms to forecast CO2 concentrations across a range of forecasting horizons. Herein, we tuned and compared six state-of-the-art learning algorithms—including Support Vector Machine, AdaBoost, Random Forest, Gradient Boosting, Logistic Regression, and Multilayer Perceptron. The algorithms’ performances are validated using CO2 and historical meteorological data collected from a campus classroom with a variable occupancy rate. Simulation results showed that Multilayer Perceptron can strongly predict the volatile CO2 behavior and also outperforms other algorithms in terms of accuracy. Furthermore, a control strategy capable of modeling and detecting dynamic patterns of CO2 level is utilized to modulate the ventilation rate in real-time and also reduce the energy consumption. The proposed controller reduced the HVAC fan’s energy consumption by 51.4% and provided ventilation as needed per the ASHRAE standards.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cortes, C., & Vapnik, V. (1995) · Machine Learning · doi:10.1007/bf00994018 · Cited by 59,421
Persily, A. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.02.026 · Cited by 249
Cited by
Himeur, Y., Elnour, M., Fadli, F., Meskin, N., Petri, I., Rezgui, Y., Bensaali, F., & Amira, A. (2023) · Artificial Intelligence Review · doi:10.1007/s10462-022-10286-2 · Cited by 541
Taheri, S., Hosseini, P., & Razban, A. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105067 · Cited by 263
Self-citationHu, Z., Gao, Y., Sun, L., Mae, M., & Imaizumi, T. (2024) · Applied Energy · doi:10.1016/j.apenergy.2024.123652 · Cited by 52
Zhang, J., Poon, K. H., Kwok, H. H. L., Hou, F., & Cheng, J. C. P. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110802 · Cited by 48
Metadata
- Authors
- Taheri, S., & Razban, A.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2021-11
- Volume
- 205
- Pages
- 108164
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W3183369445
- Cited by
- 189
- References
- 2
- FWCI
- 13.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Learning-based CO2 concentration prediction: Application to indoor air quality control using demand-controlled ventilation. https://app.cochat.ai/papers/10.1016/j.buildenv.2021.108164
- The paper
- Taheri, S., & Razban, A. (2021). Learning-based CO2 concentration prediction: Application to indoor air quality control using demand-controlled ventilation. Building and Environment. https://doi.org/10.1016/j.buildenv.2021.108164
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.